,Rev##OTHER##,W##LENGTH##INCHES,SL##LENGTH##INCHES,L##LENGTH##INCHES,Shipping Weight##OTHER##,Operating Weight##OTHER##,Remote Sump Operating Weight##OTHER##,Heaviest Section Weight##OTHER##,No. of Shipping Sections##OTHER##,Fan Motor Quantity##OTHER##,Fan Motor HP##OTHER##,H##LENGTH##INCHES,CSH##LENGTH##INCHES,CSL##LENGTH##INCHES,CH##LENGTH##INCHES,CD##LENGTH##INCHES,PH##LENGTH##INCHES,PLMH##LENGTH##INCHES,LH##LENGTH##INCHES,SELL##LENGTH##INCHES,SLL##LENGTH##INCHES,OUTD##LENGTH##INCHES,OUTLET##OTHER##,OUTL##LENGTH##INCHES,OUTFS##LENGTH##INCHES,OUTFB##LENGTH##INCHES,INL##LENGTH##INCHES,INFB##LENGTH##INCHES,INFS##LENGTH##INCHES,IND##LENGTH##INCHES,INLET##OTHER##,DNFS##LENGTH##INCHES,DNFB##LENGTH##INCHES,DNL##LENGTH##INCHES,DND##LENGTH##INCHES,DRAIN##OTHER##,OFFS##LENGTH##INCHES,OFL##LENGTH##INCHES,OFD##LENGTH##INCHES,OVERFLOW##OTHER##,OFFB##LENGTH##INCHES,MUFS##LENGTH##INCHES,MUL##LENGTH##INCHES,MUFB##LENGTH##INCHES,MUD##LENGTH##INCHES,MAKEUP##OTHER##,RSFB##LENGTH##INCHES,RSFC##LENGTH##INCHES,RSD##LENGTH##INCHES,DL##LENGTH##INCHES,DH##LENGTH##INCHES,DFT##LENGTH##INCHES,DR##LENGTH##INCHES,DFCL##LENGTH##INCHES,Model##OTHER##,CLR##LENGTH##INCHES,CLRS##LENGTH##INCHES,HDL##LENGTH##INCHES,HDCD##LENGTH##INCHES,DischargeHoodWeight##OTHER##,Sound Attenuation Weight##OTHER##,SAL##LENGTH##INCHES,SACD##LENGTH##INCHES,DAL##LENGTH##INCHES,DVCL##LENGTH##INCHES,DVHT##LENGTH##INCHES,PLTFL##LENGTH##INCHES,PLTFFB##LENGTH##INCHES,PLTFW##LENGTH##INCHES,Platform Weight##OTHER##,LDRX##LENGTH##INCHES,FBFS##LENGTH##INCHES
AT 424-2J24,2,289.125,289.75,289.75,31580,55900,36660,5790,6,4,15,198.25,43.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2J24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,138.875,39.5,560,56.25,16
AT 424-2I24,2,289.125,289.75,289.75,31020,55340,36100,5790,6,4,10,198.25,43.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2I24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,138.875,39.5,560,56.25,16
AT 424-2K24,2,289.125,289.75,289.75,31780,56100,36860,5790,6,4,20,198.25,43.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2K24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,138.875,39.5,560,56.25,16
AT 424-3J24,2,289.125,289.75,289.75,33740,58060,38820,5790,6,4,15,210.25,55.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3J24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,150.875,39.5,560,59.375,16
AT 424-3I24,2,289.125,289.75,289.75,33180,57500,38260,5790,6,4,10,210.25,55.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3I24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,150.875,39.5,560,59.375,16
AT 424-2L24,2,289.125,289.75,289.75,31980,56300,37060,5790,6,4,25,198.25,43.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2L24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,162.875,39.5,560,56.25,16
AT 424-3K24,2,289.125,289.75,289.75,33940,58260,39020,5790,6,4,20,210.25,55.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3K24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,150.875,39.5,560,59.375,16
AT 424-2M24,2,289.125,289.75,289.75,32380,56700,37460,5790,6,4,30,210.25,43.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2M24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,138.875,39.5,560,56.25,16
AT 424-4K24,2,289.125,289.75,289.75,35900,60220,40980,6080,6,4,20,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4K24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,162.875,39.5,560,59.5,16
AT 424-4J24,2,289.125,289.75,289.75,35700,60020,40780,6030,6,4,15,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4J24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,162.875,39.5,560,59.5,16
AT 424-4I24,2,289.125,289.75,289.75,35140,59460,40220,5890,6,4,10,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4I24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,162.875,39.5,560,59.5,16
AT 424-3L24,2,289.125,289.75,289.75,34140,58460,39220,5790,6,4,25,210.25,55.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3L24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,150.875,39.5,560,59.375,16
AT 424-3M24,2,289.125,289.75,289.75,34540,58860,39620,5790,6,4,30,210.25,55.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3M24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,150.875,39.5,560,59.375,16
AT 424-4N24,2,289.125,289.75,289.75,37500,61820,42580,6480,6,4,40,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4N24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,162.875,39.5,560,59.5,16
AT 424-4L24,2,289.125,289.75,289.75,36100,60420,41180,6130,6,4,25,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4L24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,162.875,39.5,560,59.5,16
AT 424-4M24,2,289.125,289.75,289.75,36500,60820,41580,6230,6,4,30,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4M24,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,43.75,64.875,162.875,39.5,560,59.5,16
AT 424-2J24-Low Sound Fan,2,289.125,289.75,289.75,31580,55900,36660,5790,6,4,15,198.25,43.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2J24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,138.875,39.5,560,56.25,16
AT 424-2I24-Low Sound Fan,2,289.125,289.75,289.75,31020,55340,36100,5790,6,4,10,198.25,43.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2I24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,138.875,39.5,560,56.25,16
AT 424-2K24-Low Sound Fan,2,289.125,289.75,289.75,31780,56100,36860,5790,6,4,20,198.25,43.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2K24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,138.875,39.5,560,56.25,16
AT 424-3J24-Low Sound Fan,2,289.125,289.75,289.75,33740,58060,38820,5790,6,4,15,210.25,55.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3J24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,150.875,39.5,560,59.375,16
AT 424-3I24-Low Sound Fan,2,289.125,289.75,289.75,33180,57500,38260,5790,6,4,10,210.25,55.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3I24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,150.875,39.5,560,59.375,16
AT 424-2L24-Low Sound Fan,2,289.125,289.75,289.75,31980,56300,37060,5790,6,4,25,198.25,43.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2L24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,162.875,39.5,560,56.25,16
AT 424-3K24-Low Sound Fan,2,289.125,289.75,289.75,34140,58460,39020,5790,6,4,20,210.25,55.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3K24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,150.875,39.5,560,59.375,16
AT 424-2M24-Low Sound Fan,2,289.125,289.75,289.75,32380,56700,37460,5790,6,4,30,210.25,43.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2M24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,138.875,39.5,560,56.25,16
AT 424-4K24-Low Sound Fan,2,289.125,289.75,289.75,35900,60220,40980,6080,6,4,20,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4K24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,162.875,39.5,560,59.5,16
AT 424-4J24-Low Sound Fan,2,289.125,289.75,289.75,35700,60020,40780,6030,6,4,15,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4J24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,162.875,39.5,560,59.5,16
AT 424-4I24-Low Sound Fan,2,289.125,289.75,289.75,35410,59460,40220,5890,6,4,10,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4I24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,162.875,39.5,560,59.5,16
AT 424-3L24-Low Sound Fan,2,289.125,289.75,289.75,34140,58460,39220,5790,6,4,25,210.25,55.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3L24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,150.875,39.5,560,59.375,16
AT 424-3M24-Low Sound Fan,2,289.125,289.75,289.75,34540,58860,39620,5790,6,4,30,210.25,55.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3M24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,150.875,39.5,560,59.375,16
AT 424-4N24-Low Sound Fan,2,289.125,289.75,289.75,37500,61820,42580,6480,6,4,40,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4N24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,162.875,39.5,560,59.5,16
AT 424-4L24-Low Sound Fan,2,289.125,289.75,289.75,36100,60420,41180,6130,6,4,25,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4L24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,162.875,39.5,560,59.5,16
AT 424-4M24-Low Sound Fan,2,289.125,289.75,289.75,36500,60820,41580,6230,6,4,30,222.25,67.75,140.5,15.25,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4M24-Low Sound Fan,48,42,143.625,16.5,7200,11760,143.625,55.625,88,19.5,75.75,64.875,162.875,39.5,560,59.5,16
AT 424-2J24-Super Low Sound Fan,2,289.125,289.75,289.75,34740,59060,39820,5790,6,4,15,219.75,43.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2J24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,138.875,39.5,560,56.25,16
AT 424-2I24-Super Low Sound Fan,2,289.125,289.75,289.75,34180,58500,39260,5790,6,4,10,219.75,43.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2I24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,138.875,39.5,560,56.25,16
AT 424-2K24-Super Low Sound Fan,2,289.125,289.75,289.75,34580,59260,40020,5840,6,4,20,219.75,43.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2K24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,138.875,39.5,560,56.25,16
AT 424-3J24-Super Low Sound Fan,2,289.125,289.75,289.75,36900,61220,41980,6330,6,4,15,231.75,55.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3J24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,150.875,39.5,560,59.375,16
AT 424-3I24-Super Low Sound Fan,2,289.125,289.75,289.75,36340,60660,41420,6190,6,4,10,231.75,55.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3I24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,150.875,39.5,560,59.375,16
AT 424-2L24-Super Low Sound Fan,2,289.125,289.75,289.75,35140,59460,40220,5890,6,4,25,219.75,43.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2L24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,162.875,39.5,560,56.25,16
AT 424-3K24-Super Low Sound Fan,2,289.125,289.75,289.75,37100,61420,42180,6380,6,4,20,231.75,55.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3K24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,150.875,39.5,560,59.375,16
AT 424-2M24-Super Low Sound Fan,2,289.125,289.75,289.75,35540,59860,40620,5990,6,4,30,219.75,43.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,134,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-2M24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,138.875,39.5,560,56.25,16
AT 424-4K24-Super Low Sound Fan,2,289.125,289.75,289.75,39060,63380,44140,6870,6,4,20,243.75,67.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4K24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,162.875,39.5,560,59.5,16
AT 424-4J24-Super Low Sound Fan,2,289.125,289.75,289.75,38860,63180,43940,6820,6,4,15,243.75,67.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4J24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,162.875,39.5,560,59.5,16
AT 424-4I24-Super Low Sound Fan,2,289.125,289.75,289.75,38300,62620,43380,6680,6,4,10,243.75,67.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4I24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,162.875,39.5,560,59.5,16
AT 424-3L24-Super Low Sound Fan,2,289.125,289.75,289.75,37300,61620,42380,6430,6,4,25,231.75,55.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3L24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,150.875,39.5,560,59.375,16
AT 424-3M24-Super Low Sound Fan,2,289.125,289.75,289.75,37700,62020,42780,6530,6,4,30,231.75,55.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,146,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-3M24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,150.875,39.5,560,59.375,16
AT 424-4N24-Super Low Sound Fan,2,289.125,289.75,289.75,39660,63980,44740,7020,6,4,40,243.75,67.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4N24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,162.875,39.5,560,59.5,16
AT 424-4L24-Super Low Sound Fan,2,289.125,289.75,289.75,39260,63580,44340,6920,6,4,25,243.75,67.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4L24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,162.875,39.5,560,59.5,16
AT 424-4M24-Super Low Sound Fan,2,289.125,289.75,289.75,39660,63980,44740,7020,6,4,30,243.75,67.75,140.5,36.75,140.5,19,7.125,72.125,30.625,30.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,9.5,2,158,12,8,"8"" [200] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",71.875,117.875,8,57.25,33.625,3.75,1.75,10.125,AT 424-4M24-Super Low Sound Fan,48,42,143.625,16.5,8600,11760,143.625,55.625,88,19.5,54.25,64.875,162.875,39.5,560,59.5,16
AT 424-2K28,2,289.125,337.75,337.75,35060,63960,41440,6550,6,4,20,198.25,43.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2K28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,580,63,195.25
AT 424-2J28,2,289.125,337.75,337.75,34820,63720,41200,6550,6,4,15,198.25,43.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2J28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,580,63,195.25
AT 424-2I28,2,289.125,337.75,337.75,34260,63160,40640,6550,6,4,10,198.25,43.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2I28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,580,63,195.25
AT 424-4J28,2,289.125,337.75,337.75,39540,68440,45920,6610,6,4,15,222.25,67.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4J28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,580,67.6875,195.25
AT 424-4I28,2,289.125,337.75,337.75,38980,67880,45360,6550,6,4,10,222.25,67.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4I28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,580,67.6875,195.25
AT 424-2M28,2,289.125,337.75,337.75,35580,64480,41960,6550,6,4,30,198.25,43.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2M28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,580,63,195.25
AT 424-2L28,2,289.125,337.75,337.75,35300,64200,41680,6550,6,4,25,198.25,43.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2L28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,580,63,195.25
AT 424-3K28,2,289.125,337.75,337.75,37700,66600,44080,6550,6,4,20,210.25,55.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3K28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-3J28,2,289.125,337.75,337.75,37460,66360,43840,6550,6,4,15,210.25,55.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3J28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-3I28,2,289.125,337.75,337.75,36900,65800,43280,6550,6,4,10,210.25,55.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3I28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-4K28,2,289.125,337.75,337.75,39780,68680,46160,6670,6,4,20,222.25,67.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4K28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,580,67.6875,195.25
AT 424-3L28,2,289.125,337.75,337.75,37940,66840,44320,6550,6,4,25,210.25,55.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3L28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-4L28,2,289.125,337.75,337.75,40020,68920,46400,6730,6,4,25,222.25,67.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4L28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,580,67.6875,195.25
AT 424-3N28,2,289.125,337.75,337.75,39260,68160,45640,6550,6,4,40,210.25,55.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3N28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-3M28,2,289.125,337.75,337.75,38220,67120,44600,6550,6,4,30,210.25,55.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3M28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-4M28,2,289.125,337.75,337.75,40300,69200,46680,6800,6,4,30,222.25,67.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4M28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,580,67.6875,195.25
AT 424-4N28,2,289.125,337.75,337.75,41340,70240,47720,7060,6,4,40,222.25,67.75,164.5,15.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4N28,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,580,67.6875,195.25
AT 424-2K28-Low Sound Fan,2,289.125,337.75,337.75,35960,64860,42960,6550,6,4,20,205.25,43.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2K28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,138.875,39.5,580,63,195.25
AT 424-2J28-Low Sound Fan,2,289.125,337.75,337.75,35720,64620,42100,6550,6,4,15,205.25,43.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2J28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,138.875,39.5,580,63,195.25
AT 424-2I28-Low Sound Fan,2,289.125,337.75,337.75,35160,64060,41540,6550,6,4,10,205.25,43.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2I28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,138.875,39.5,580,63,195.25
AT 424-4J28-Low Sound Fan,2,289.125,337.75,337.75,40440,69340,46820,6835,6,4,15,229.25,67.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4J28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,162.875,39.5,580,67.6875,195.25
AT 424-4I28-Low Sound Fan,2,289.125,337.75,337.75,39880,68780,46260,6695,6,4,10,229.25,67.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4I28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,162.875,39.5,580,67.6875,195.25
AT 424-2M28-Low Sound Fan,2,289.125,337.75,337.75,36480,65380,42860,6550,6,4,30,205.25,43.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2M28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,138.875,39.5,580,63,195.25
AT 424-2L28-Low Sound Fan,2,289.125,337.75,337.75,36200,65100,42580,6550,6,4,25,205.25,43.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2L28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,138.875,39.5,580,63,195.25
AT 424-3K28-Low Sound Fan,2,289.125,337.75,337.75,38600,67500,44980,6550,6,4,20,217.25,55.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3K28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-3J28-Low Sound Fan,2,289.125,337.75,337.75,38360,67260,44740,6550,6,4,15,217.25,55.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3J28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-3I28-Low Sound Fan,2,289.125,337.75,337.75,37800,66700,44180,6550,6,4,10,217.25,55.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3I28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-4K28-Low Sound Fan,2,289.125,337.75,337.75,40680,69580,47060,6895,6,4,20,229.25,67.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4K28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,162.875,39.5,580,67.6875,195.25
AT 424-3L28-Low Sound Fan,2,289.125,337.75,337.75,38840,67740,45220,6550,6,4,25,217.25,55.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3L28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-4L28-Low Sound Fan,2,289.125,337.75,337.75,40920,69820,47300,6955,6,4,25,229.25,67.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4L28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,162.875,39.5,580,67.6875,195.25
AT 424-3N28-Low Sound Fan,2,289.125,337.75,337.75,40160,69060,46540,6765,6,4,40,217.25,55.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3N28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-3M28-Low Sound Fan,2,289.125,337.75,337.75,39120,68020,45500,6550,6,4,30,217.25,55.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3M28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,150.875,39.5,580,66.0625,195.25
AT 424-4M28-Low Sound Fan,2,289.125,337.75,337.75,41200,70100,47580,7025,6,4,30,229.25,67.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4M28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,150.875,39.5,580,67.6875,195.25
AT 424-4N28-Low Sound Fan,2,289.125,337.75,337.75,42240,71140,48620,7285,6,4,40,229.25,67.75,164.5,22.25,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4N28-Low Sound Fan,54,42,157.5,16.5,7200,13400,157.5,55.625,88,19.5,75.75,64.875,150.875,39.5,580,67.6875,195.25
AT 424-2K28-Super Low Sound Fan,2,289.125,337.75,337.75,39860,68760,42640,6690,6,4,20,213.75,43.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2K28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,138.875,39.5,580,63,195.25
AT 424-2J28-Super Low Sound Fan,2,289.125,337.75,337.75,39380,68280,45760,6570,6,4,15,213.75,43.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2J28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,138.875,39.5,580,63,195.25
AT 424-2I28-Super Low Sound Fan,2,289.125,337.75,337.75,38820,67720,45200,6550,6,4,10,213.75,43.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2I28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,138.875,39.5,580,63,195.25
AT 424-4J28-Super Low Sound Fan,2,289.125,337.75,337.75,42020,70920,48400,7230,6,4,15,237.75,67.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4J28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,162.875,39.5,580,67.6875,195.25
AT 424-4I28-Super Low Sound Fan,2,289.125,337.75,337.75,43540,72440,49920,7610,6,4,10,237.75,67.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4I28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,162.875,39.5,580,67.6875,195.25
AT 424-2M28-Super Low Sound Fan,2,289.125,337.75,337.75,40140,69040,46520,6760,6,4,30,213.75,43.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2M28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,138.875,39.5,580,63,195.25
AT 424-2L28-Super Low Sound Fan,2,289.125,337.75,337.75,39860,68760,46240,6690,6,4,25,213.75,43.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-2L28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,138.875,39.5,580,63,195.25
AT 424-3K28-Super Low Sound Fan,2,289.125,337.75,337.75,42260,71160,48640,7290,6,4,20,225.75,55.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3K28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,150.875,39.5,580,66.0625,195.25
AT 424-3J28-Super Low Sound Fan,2,289.125,337.75,337.75,42020,70920,48400,7230,6,4,15,225.75,55.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3J28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,150.875,39.5,580,66.0625,195.25
AT 424-3I28-Super Low Sound Fan,2,289.125,337.75,337.75,41460,70360,47840,7090,6,4,10,225.75,55.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3I28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,150.875,39.5,580,66.0625,195.25
AT 424-4K28-Super Low Sound Fan,2,289.125,337.75,337.75,44340,73240,50720,7810,6,4,20,237.75,67.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4K28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,162.875,39.5,580,67.6875,195.25
AT 424-3L28-Super Low Sound Fan,2,289.125,337.75,337.75,42500,71400,48880,7350,6,4,25,225.75,55.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3L28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,150.875,39.5,580,66.0625,195.25
AT 424-4L28-Super Low Sound Fan,2,289.125,337.75,337.75,44580,73480,50960,7870,6,4,25,237.75,67.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4L28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,162.875,39.5,580,67.6875,195.25
AT 424-3N28-Super Low Sound Fan,2,289.125,337.75,337.75,43820,72720,50200,7680,6,4,40,225.75,55.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3N28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,150.875,39.5,580,66.0625,195.25
AT 424-3M28-Super Low Sound Fan,2,289.125,337.75,337.75,42780,71920,49160,7420,6,4,30,213.75,55.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-3M28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,150.875,39.5,580,66.0625,195.25
AT 424-4M28-Super Low Sound Fan,2,289.125,337.75,337.75,44860,73760,51240,7940,6,4,30,237.75,67.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4M28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,150.875,39.5,580,67.6875,195.25
AT 424-4N28-Super Low Sound Fan,2,289.125,337.75,337.75,45900,74800,52280,8200,6,4,40,237.75,67.75,164.5,30.75,140.5,19,7.125,72.125,30.625,36.75,12,"12"" [300] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",65.875,118,10,57.25,33.625,3.75,1.75,10.125,AT 424-4N28-Super Low Sound Fan,54,42,157.5,16.5,8400,13400,157.5,55.625,88,19.5,54.25,64.875,150.875,39.5,580,67.6875,195.25
AT 424-2K36,2,289.125,434.25,434.25,44080,80780,51700,8520,6,4,20,198.25,43.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2K36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,620,89,237.75
AT 424-2J36,2,289.125,434.25,434.25,43840,80540,51460,8520,6,4,15,198.25,43.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2J36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,620,89,237.75
AT 424-2L36,2,289.125,434.25,434.25,44280,80980,51900,8520,6,4,25,198.25,43.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2L36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,620,89,237.75
AT 424-3L36,2,289.125,434.25,434.25,47400,84100,55020,8520,6,4,25,210.25,55.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3L36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,620,92,237.75
AT 424-3K36,2,289.125,434.25,434.25,47200,83900,54820,8520,6,4,20,210.25,55.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3K36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,620,92,237.75
AT 424-3J36,2,289.125,434.25,434.25,46960,83660,54580,8520,6,4,15,210.25,55.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3J36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,620,92,237.75
AT 424-2N36,2,289.125,434.25,434.25,45760,82460,53380,8520,6,4,40,198.25,43.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2N36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,620,89,237.75
AT 424-2M36,2,289.125,434.25,434.25,44720,81420,52340,8520,6,4,30,198.25,43.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2M36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,620,89,237.75
AT 424-3M36,2,289.125,434.25,434.25,47840,84540,55460,8520,6,4,30,210.25,55.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3M36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,620,92,237.75
AT 424-4M36,2,289.125,434.25,434.25,50800,87500,58420,8520,6,4,30,222.25,67.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4M36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-4L36,2,289.125,434.25,434.25,50360,87060,57980,8520,6,4,25,222.25,67.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4L36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-4K36,2,289.125,434.25,434.25,50160,86860,57780,8520,6,4,20,222.25,67.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4K36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-4J36,2,289.125,434.25,434.25,49920,86620,57540,8520,6,4,15,222.25,67.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4J36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-3N36,2,289.125,434.25,434.25,48880,85580,56500,8520,6,4,40,210.25,55.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3N36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,620,92,237.75
AT 424-3O36,2,289.125,434.25,434.25,49120,85820,56740,8520,6,4,50,210.25,55.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3O36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,620,92,237.75
AT 424-4O36,2,289.125,434.25,434.25,52080,88780,59700,8760,6,4,50,222.25,67.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4O36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-4N36,2,289.125,434.25,434.25,51840,88540,59460,8700,6,4,40,222.25,67.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4N36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-4P36,2,289.125,434.25,434.25,52520,89220,60140,8870,6,4,60,222.25,67.75,212.75,15.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4P36,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-2K36-Low Sound Fan,2,289.125,434.25,434.25,44080,80780,51700,8520,6,4,20,205.25,43.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2K36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,138.875,39.5,620,89,237.75
AT 424-2J36-Low Sound Fan,2,289.125,434.25,434.25,43840,80540,51460,8520,6,4,15,205.25,43.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2J36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,138.875,39.5,620,89,237.75
AT 424-2L36-Low Sound Fan,2,289.125,434.25,434.25,44280,80980,51900,8520,6,4,25,205.25,43.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2L36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,138.875,39.5,620,89,237.75
AT 424-3L36-Low Sound Fan,2,289.125,434.25,434.25,47400,84100,55020,8520,6,4,25,217.25,55.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3L36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,150.875,39.5,620,92,237.75
AT 424-3K36-Low Sound Fan,2,289.125,434.25,434.25,47200,83900,54820,8520,6,4,20,217.25,55.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3K36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,150.875,39.5,620,92,237.75
AT 424-3J36-Low Sound Fan,2,289.125,434.25,434.25,46960,83660,54580,8520,6,4,15,217.25,55.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3J36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,150.875,39.5,620,92,237.75
AT 424-2N36-Low Sound Fan,2,289.125,434.25,434.25,45760,82460,53380,8520,6,4,40,205.25,43.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2N36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,138.875,39.5,620,89,237.75
AT 424-2M36-Low Sound Fan,2,289.125,434.25,434.25,44720,81420,52340,8520,6,4,30,205.25,43.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2M36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,138.875,39.5,620,89,237.75
AT 424-3M36-Low Sound Fan,2,289.125,434.25,434.25,47840,84540,55460,8520,6,4,30,217.25,55.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3M36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,150.875,39.5,620,92,237.75
AT 424-4M36-Low Sound Fan,2,289.125,434.25,434.25,50800,87500,58420,8520,6,4,30,229.25,67.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4M36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-4L36-Low Sound Fan,2,289.125,434.25,434.25,50360,87060,57980,8520,6,4,25,229.25,67.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4L36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-4K36-Low Sound Fan,2,289.125,434.25,434.25,50160,86860,57780,8520,6,4,20,229.25,67.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4K36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-4J36-Low Sound Fan,2,289.125,434.25,434.25,49920,86620,57540,8520,6,4,15,229.25,67.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4J36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-3N36-Low Sound Fan,2,289.125,434.25,434.25,48880,85580,56500,8520,6,4,40,217.25,55.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3N36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,150.875,39.5,620,92,237.75
AT 424-3O36-Low Sound Fan,2,289.125,434.25,434.25,49120,85820,56740,8520,6,4,50,217.25,55.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3O36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,150.875,39.5,620,92,237.75
AT 424-4O36-Low Sound Fan,2,289.125,434.25,434.25,52080,88780,59700,8760,6,4,50,229.25,67.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4O36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-4N36-Low Sound Fan,2,289.125,434.25,434.25,51840,88540,59460,8700,6,4,40,229.25,67.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4N36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-4P36-Low Sound Fan,2,289.125,434.25,434.25,52520,89220,60140,8870,6,4,60,229.25,67.75,212.75,22.25,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4P36-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,620,90.625,237.75
AT 424-2K36-Super Low Sound Fan,2,289.125,434.25,434.25,49040,85740,56660,8520,6,4,20,213.75,43.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2K36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,138.875,39.5,620,89,237.75
AT 424-2J36-Super Low Sound Fan,2,289.125,434.25,434.25,48800,85500,56420,8520,6,4,15,213.75,43.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2J36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,138.875,39.5,620,89,237.75
AT 424-2L36-Super Low Sound Fan,2,289.125,434.25,434.25,49240,85940,56860,8520,6,4,25,213.75,43.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2L36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,138.875,39.5,620,89,237.75
AT 424-3L36-Super Low Sound Fan,2,289.125,434.25,434.25,52360,89060,59980,8830,6,4,25,225.75,55.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3L36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,150.875,39.5,620,92,237.75
AT 424-3K36-Super Low Sound Fan,2,289.125,434.25,434.25,52160,88860,59780,8780,6,4,20,225.75,55.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3K36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,150.875,39.5,620,92,237.75
AT 424-3J36-Super Low Sound Fan,2,289.125,434.25,434.25,51920,88620,59540,8720,6,4,15,225.75,55.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3J36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,150.875,39.5,620,92,237.75
AT 424-2N36-Super Low Sound Fan,2,289.125,434.25,434.25,50720,87420,58340,8520,6,4,40,213.75,43.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2N36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,138.875,39.5,620,89,237.75
AT 424-2M36-Super Low Sound Fan,2,289.125,434.25,434.25,49680,86380,57300,8520,6,4,30,213.75,43.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2M36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,138.875,39.5,620,89,237.75
AT 424-3M36-Super Low Sound Fan,2,289.125,434.25,434.25,52800,89500,60420,8940,6,4,30,225.75,55.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3M36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,150.875,39.5,620,92,237.75
AT 424-4M36-Super Low Sound Fan,2,289.125,434.25,434.25,55760,92460,63380,9680,6,4,30,237.75,67.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4M36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,620,90.625,237.75
AT 424-4L36-Super Low Sound Fan,2,289.125,434.25,434.25,55320,92020,62940,9570,6,4,25,237.75,67.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4L36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,620,90.625,237.75
AT 424-4K36-Super Low Sound Fan,2,289.125,434.25,434.25,55120,91820,62740,9520,6,4,20,237.75,67.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4K36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,620,90.625,237.75
AT 424-4J36-Super Low Sound Fan,2,289.125,434.25,434.25,54880,91580,62500,9460,6,4,15,237.75,67.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4J36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,620,90.625,237.75
AT 424-3N36-Super Low Sound Fan,2,289.125,434.25,434.25,53840,90540,61460,9200,6,4,40,225.75,55.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3N36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,150.875,39.5,620,92,237.75
AT 424-3O36-Super Low Sound Fan,2,289.125,434.25,434.25,54080,90780,61700,9260,6,4,50,225.75,55.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3O36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,150.875,39.5,620,92,237.75
AT 424-4O36-Super Low Sound Fan,2,289.125,434.25,434.25,57040,93740,64660,10000,6,4,50,237.75,67.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4O36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,620,90.625,237.75
AT 424-4N36-Super Low Sound Fan,2,289.125,434.25,434.25,56800,93500,64420,9940,6,4,40,237.75,67.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4N36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,620,90.625,237.75
AT 424-4P36-Super Low Sound Fan,2,289.125,434.25,434.25,57480,94180,65100,10110,6,4,60,237.75,67.75,212.75,30.75,140.5,19,7.125,72.125,30.625,31.125,10,"10"" [250] BFW/GVD OUTLET",0.375,117.875,8.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",90,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4P36-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,620,90.625,237.75
AT 424-2K40,2,289.125,482.25,482.25,46840,88040,55680,9000,6,4,20,198.25,43.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2K40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,640,103.5,269.75
AT 424-2L40,2,289.125,482.25,482.25,47040,88240,55880,9000,6,4,25,198.25,43.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2L40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,640,103.5,269.75
AT 424-2M40,2,289.125,482.25,482.25,47480,88680,56320,9000,6,4,30,198.25,43.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2M40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,640,103.5,269.75
AT 424-2N40,2,289.125,482.25,482.25,48520,89720,57360,9000,6,4,40,198.25,43.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2N40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,640,103.5,269.75
AT 424-2O40,2,289.125,482.25,482.25,48760,89960,57600,9000,6,4,50,198.25,43.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2O40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,138.875,39.5,640,103.5,269.75
AT 424-3K40,2,289.125,482.25,482.25,49760,90960,58600,9000,6,4,20,210.25,55.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3K40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3L40,2,289.125,482.25,482.25,49960,91160,58800,9000,6,4,25,210.25,55.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3L40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3M40,2,289.125,482.25,482.25,50400,91600,59240,9000,6,4,30,210.25,55.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3M40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3N40,2,289.125,482.25,482.25,51440,92640,60280,9000,6,4,40,210.25,55.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3N40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3O40,2,289.125,482.25,482.25,51680,92880,60520,9000,6,4,50,210.25,55.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3O40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,150.875,39.5,640,103.5625,269.75
AT 424-4K40,2,289.125,482.25,482.25,53360,94560,62200,9000,6,4,20,222.25,67.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4K40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4L40,2,289.125,482.25,482.25,53560,94760,62400,9000,6,4,25,222.25,67.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4L40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4M40,2,289.125,482.25,482.25,54000,95200,62840,9000,6,4,30,222.25,67.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4M40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4N40,2,289.125,482.25,482.25,55040,96240,63880,9260,6,4,40,222.25,67.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4N40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4O40,2,289.125,482.25,482.25,55280,96480,64120,9320,6,4,50,222.25,67.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4O40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4P40,2,289.125,482.25,482.25,55720,96920,64560,9430,6,4,60,222.25,67.75,236.75,15.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4P40,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,43.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-2K40-Low Sound Fan,2,289.125,482.25,482.25,47740,88940,55905,9000,6,4,20,205.25,43.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2K40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,138.875,39.5,640,103.5,269.75
AT 424-2L40-Low Sound Fan,2,289.125,482.25,482.25,47940,89140,56105,9000,6,4,25,205.25,43.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2L40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,138.875,39.5,640,103.5,269.75
AT 424-2M40-Low Sound Fan,2,289.125,482.25,482.25,48380,89580,56545,9000,6,4,30,205.25,43.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2M40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,138.875,39.5,640,103.5,269.75
AT 424-2N40-Low Sound Fan,2,289.125,482.25,482.25,49420,90620,57585,9000,6,4,40,205.25,43.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2N40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,138.875,39.5,640,103.5,269.75
AT 424-2O40-Low Sound Fan,2,289.125,482.25,482.25,49660,90860,57825,9000,6,4,50,205.25,43.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2O40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,138.875,39.5,640,103.5,269.75
AT 424-3K40-Low Sound Fan,2,289.125,482.25,482.25,50660,91860,58825,9000,6,4,20,217.25,55.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3K40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3L40-Low Sound Fan,2,289.125,482.25,482.25,50860,92060,59025,9000,6,4,25,217.25,55.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3L40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3M40-Low Sound Fan,2,289.125,482.25,482.25,51300,92500,59465,9000,6,4,30,217.25,55.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3M40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3N40-Low Sound Fan,2,289.125,482.25,482.25,52340,93540,60505,9000,6,4,40,217.25,55.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3N40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3O40-Low Sound Fan,2,289.125,482.25,482.25,52580,93780,60745,9000,6,4,50,217.25,55.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3O40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,150.875,39.5,640,103.5625,269.75
AT 424-4K40-Low Sound Fan,2,289.125,482.25,482.25,54260,95460,62425,9000,6,4,20,229.25,67.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4K40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4L40-Low Sound Fan,2,289.125,482.25,482.25,54460,95660,62625,9000,6,4,25,229.25,67.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4L40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4M40-Low Sound Fan,2,289.125,482.25,482.25,54900,96100,63065,9900,6,4,30,229.25,67.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4M40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4N40-Low Sound Fan,2,289.125,482.25,482.25,55940,97140,64105,10160,6,4,40,229.25,67.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4N40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4O40-Low Sound Fan,2,289.125,482.25,482.25,56180,97380,64345,10220,6,4,50,229.25,67.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4O40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4P40-Low Sound Fan,2,289.125,482.25,482.25,56620,97820,64785,10330,6,4,60,229.25,67.75,236.75,22.25,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4P40-Low Sound Fan,72,54,157.5,16.5,7200,13400,157.5,55.625,88,19.5,68.75,64.875,162.875,39.5,640,103.6875,269.75
AT 424-2K40-Super Low Sound Fan,2,289.125,482.25,482.25,51800,9300,60640,9000,6,4,20,213.75,43.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2K40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,138.875,39.5,640,103.5,269.75
AT 424-2L40-Super Low Sound Fan,2,289.125,482.25,482.25,52000,93200,60840,9000,6,4,25,213.75,43.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2L40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,138.875,39.5,640,103.5,269.75
AT 424-2M40-Super Low Sound Fan,2,289.125,482.25,482.25,52440,93640,61280,9000,6,4,30,213.75,43.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2M40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,138.875,39.5,640,103.5,269.75
AT 424-2N40-Super Low Sound Fan,2,289.125,482.25,482.25,53480,94680,62320,9000,6,4,40,213.75,43.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2N40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,138.875,39.5,640,103.5,269.75
AT 424-2O40-Super Low Sound Fan,2,289.125,482.25,482.25,53752,94920,62560,9000,6,4,50,213.75,43.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,133,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-2O40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,138.875,39.5,640,103.5,269.75
AT 424-3K40-Super Low Sound Fan,2,289.125,482.25,482.25,54720,95920,63560,9180,6,4,20,225.75,55.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3K40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3L40-Super Low Sound Fan,2,289.125,482.25,482.25,54920,96120,63760,9230,6,4,25,225.75,55.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3L40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3M40-Super Low Sound Fan,2,289.125,482.25,482.25,55360,96560,64200,9340,6,4,30,225.75,55.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3M40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3N40-Super Low Sound Fan,2,289.125,482.25,482.25,56400,97600,65240,9600,6,4,40,225.75,55.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3N40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,150.875,39.5,640,103.5625,269.75
AT 424-3O40-Super Low Sound Fan,2,289.125,482.25,482.25,56640,97840,65480,9660,6,4,50,225.75,55.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,145,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-3O40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,150.875,39.5,640,103.5625,269.75
AT 424-4K40-Super Low Sound Fan,2,289.125,482.25,482.25,58320,99520,67160,10080,6,4,20,237.75,67.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4K40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4L40-Super Low Sound Fan,2,289.125,482.25,482.25,58520,99720,10130,9000,6,4,25,237.75,67.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4L40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4M40-Super Low Sound Fan,2,289.125,482.25,482.25,58960,100160,67800,10240,6,4,30,237.75,67.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4M40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4N40-Super Low Sound Fan,2,289.125,482.25,482.25,60000,101200,68840,10500,6,4,40,237.75,67.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4N40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4O40-Super Low Sound Fan,2,289.125,482.25,482.25,60240,101440,10560,14120,6,4,50,237.75,67.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4O40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,640,103.6875,269.75
AT 424-4P40-Super Low Sound Fan,2,289.125,482.25,482.25,60680,101880,69520,10670,6,4,60,237.75,67.75,236.75,30.75,140.5,19,7.125,72.125,30.625,35.125,10,"10"" [250] BFW/GVD OUTLET",1.375,117.875,9.5,2,157,12,10,"10"" [250] BFW/GVD INLET",137.75,3.625,1.375,3,"3"" [80] MPT DRAIN",133,1.375,3,"3"" [80] MPT OVERFLOW",16.875,136.75,0.375,25.25,2,"2"" [50] MPT MAKE-UP",102.25,117.875,10,57.25,33.625,3.75,1.75,10.125,AT 424-4P40-Super Low Sound Fan,72,54,157.5,16.5,8400,13400,157.5,55.625,88,19.5,60.375,64.875,162.875,39.5,640,103.6875,269.75
AT 428-2M48,2,339.625,285,613,66840,130240,90840,10670,8,4,30,209.625,43.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,3,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2M48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,141.875,39.5,610,129.1875,17
AT 428-2L48,2,339.625,285,613,66760,130160,90760,10650,8,4,25,209.625,43.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2L48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,141.875,39.5,610,129.1875,17
AT 428-2K48,2,339.625,285,613,65560,129960,90560,10600,8,4,20,209.625,43.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2K48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,141.875,39.5,610,129.1875,17
AT 428-2N48,2,339.625,285,613,67440,130840,91440,10820,8,4,40,209.625,43.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2N48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,141.875,39.5,610,129.1875,17
AT 428-2O48,2,339.625,285,613,68840,132240,92840,11170,8,4,50,209.625,43.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2O48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,141.875,39.5,610,129.1875,17
AT 428-4L48,2,339.625,285,613,75080,138480,99080,12730,8,4,25,233.625,67.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4L48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-4K48,2,339.625,285,613,74880,138280,98880,12680,8,4,20,233.625,67.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4K48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-4M48,2,339.625,285,613,75160,138560,99160,12750,8,4,30,233.625,67.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4M48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-3N48,2,339.625,285,613,71600,135000,95600,11860,8,4,40,221.625,55.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3N48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-3M48,2,339.625,285,613,71000,134400,95000,11710,8,4,30,221.625,55.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3M48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-3L48,2,339.625,285,613,70920,134320,94920,11690,8,4,25,221.625,55.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3L48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-3K48,2,339.625,285,613,70720,134120,94720,11640,8,4,20,221.625,55.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3K48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-3O48,2,339.625,285,613,73000,136400,97000,12210,8,4,50,221.625,55.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3O48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-4N48,2,339.625,285,613,75760,139160,99760,12900,8,4,40,233.625,67.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4N48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-4O48,2,339.625,285,613,77160,140560,101160,13250,8,4,50,233.625,67.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4O48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-3P48,2,339.625,285,613,73680,137080,97680,12380,8,4,60,221.625,55.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3P48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-4P48,2,339.625,285,613,77840,141240,101840,13420,8,4,60,233.625,67.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4P48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-4Q48,2,339.625,285,613,78800,142200,102800,13660,8,4,75,233.625,67.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4Q48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-4R48,2,339.625,285,613,80560,143960,104560,14100,8,4,100,233.625,67.75,96,17.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4R48,72,54,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-2M48-Low Sound Fan,2,339.625,285,613,69240,132640,93240,11270,8,4,30,214.625,43.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2M48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,141.875,39.5,610,129.1875,17
AT 428-2L48-Low Sound Fan,2,339.625,285,613,68560,131960,92560,11100,8,4,25,214.625,43.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2L48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,141.875,39.5,610,129.1875,17
AT 428-2K48-Low Sound Fan,2,339.625,285,613,68360,131760,92360,11050,8,4,20,214.625,43.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2K48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,141.875,39.5,610,129.1875,17
AT 428-2N48-Low Sound Fan,2,339.625,285,613,69240,132640,93240,11270,8,4,40,214.625,43.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2N48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,141.875,39.5,610,129.1875,17
AT 428-2O48-Low Sound Fan,2,339.625,285,613,70640,134040,94640,11620,8,4,50,214.625,43.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2O48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,141.875,39.5,610,129.1875,17
AT 428-4L48-Low Sound Fan,2,339.625,285,613,76880,140280,100880,13180,8,4,25,238.625,67.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4L48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-4K48-Low Sound Fan,2,339.625,285,613,76680,140080,100680,13130,8,4,20,238.625,67.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4K48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-4M48-Low Sound Fan,2,339.625,285,613,76960,140360,100960,13200,8,4,30,238.625,67.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4M48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-3N48-Low Sound Fan,2,339.625,285,613,73400,136800,97400,12310,8,4,40,226.625,55.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3N48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-3M48-Low Sound Fan,2,339.625,285,613,72800,136200,96800,12160,8,4,30,226.625,55.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3M48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-3L48-Low Sound Fan,2,339.625,285,613,72720,136120,96720,12140,8,4,25,226.625,55.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3L48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-3K48-Low Sound Fan,2,339.625,285,613,72520,135920,96520,12090,8,4,20,226.625,55.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3K48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-3O48-Low Sound Fan,2,339.625,285,613,74800,138200,98800,12660,8,4,50,226.625,55.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3O48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-4N48-Low Sound Fan,2,339.625,285,613,77560,140960,101560,13350,8,4,40,238.625,67.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4N48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-4O48-Low Sound Fan,2,339.625,285,613,78960,142360,102960,13700,8,4,50,238.625,67.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4O48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-3P48-Low Sound Fan,2,339.625,285,613,75480,138880,99480,12830,8,4,60,226.625,55.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3P48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,153.875,39.5,610,127.625,17
AT 428-4P48-Low Sound Fan,2,339.625,285,613,79640,143040,103640,13870,8,4,60,238.625,67.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4P48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-4Q48-Low Sound Fan,2,339.625,285,613,80600,144000,104600,14110,8,4,75,238.625,67.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4Q48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-4R48-Low Sound Fan,2,339.625,285,613,82360,145760,106360,14550,8,4,100,238.625,67.75,96,22.25,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4R48-Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,41.75,64.625,165.875,39.5,610,130.75,17
AT 428-2M48-Super Low Sound Fan,2,339.625,285,613,71920,135320,11940,20270,8,4,30,223.125,43.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2M48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,141.875,39.5,610,129.1875,17
AT 428-2L48-Super Low Sound Fan,2,339.625,285,613,71240,134640,95240,11770,8,4,25,223.125,43.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2L48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,141.875,39.5,610,129.1875,17
AT 428-2K48-Super Low Sound Fan,2,339.625,285,613,71040,134440,95040,11720,8,4,20,223.125,43.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2K48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,141.875,39.5,610,129.1875,17
AT 428-2N48-Super Low Sound Fan,2,339.625,285,613,71920,135320,95920,11940,8,4,40,223.125,43.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2N48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,141.875,39.5,610,129.1875,17
AT 428-2O48-Super Low Sound Fan,2,339.625,285,613,73320,136720,97320,12290,8,4,50,223.125,43.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,135.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-2O48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,141.875,39.5,610,129.1875,17
AT 428-4L48-Super Low Sound Fan,2,339.625,285,613,79560,142960,13560,8550,12,4,25,247.125,67.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4L48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,165.875,39.5,610,130.75,17
AT 428-4K48-Super Low Sound Fan,2,339.625,285,613,79360,142760,103360,8550,12,4,20,247.125,67.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4K48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,165.875,39.5,610,130.75,17
AT 428-4M48-Super Low Sound Fan,2,339.625,285,613,79640,143040,103640,8550,12,4,30,247.125,67.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4M48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,165.875,39.5,610,130.75,17
AT 428-3N48-Super Low Sound Fan,2,339.625,285,613,76080,139480,100080,12980,8,4,40,235.125,55.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3N48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,153.875,39.5,610,127.625,17
AT 428-3M48-Super Low Sound Fan,2,339.625,285,613,75480,138880,99480,12830,8,4,30,235.125,55.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3M48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,153.875,39.5,610,127.625,17
AT 428-3L48-Super Low Sound Fan,2,339.625,285,613,75400,138800,99400,12810,8,4,25,235.125,55.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3L48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,153.875,39.5,610,127.625,17
AT 428-3K48-Super Low Sound Fan,2,339.625,285,613,75200,138600,99200,12760,8,4,20,235.125,55.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3K48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,153.875,39.5,610,127.625,17
AT 428-3O48-Super Low Sound Fan,2,339.625,285,613,77480,140880,101480,13330,8,4,50,235.125,55.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3O48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,153.875,39.5,610,127.625,17
AT 428-4N48-Super Low Sound Fan,2,339.625,285,613,80240,143640,104240,8550,12,4,40,247.125,67.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4N48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,165.875,39.5,610,130.75,17
AT 428-4O48-Super Low Sound Fan,2,339.625,285,613,81640,145040,105640,8550,12,4,50,247.125,67.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4O48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,165.875,39.5,610,130.75,17
AT 428-3P48-Super Low Sound Fan,2,339.625,285,613,78160,141560,102160,13500,8,4,60,235.125,55.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,147.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-3P48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,153.875,39.5,610,127.625,17
AT 428-4P48-Super Low Sound Fan,2,339.625,285,613,82320,145720,106320,8550,12,4,60,247.125,67.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4P48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,165.875,39.5,610,130.75,17
AT 428-4Q48-Super Low Sound Fan,2,339.625,285,613,83280,146680,107280,8550,12,4,75,247.125,67.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4Q48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,165.875,39.5,610,130.75,17
AT 428-4R48-Super Low Sound Fan,2,339.625,285,613,85040,148440,109040,8550,12,4,100,247.125,67.75,96,30.75,164.5,20,6.625,72.625,37,30.25,14,"14"" [350] BFW/GVD OUTLET",1.5,138,9,2,159.875,142.5,14,"14"" [350] BFW/GVD INLET",162.125,4.125,1.5,4,"4"" [100] MPT DRAIN",157.375,1.5,4,"4"" [100] MPT OVERFLOW",17.375,161.625,0.375,26,2,"3"" [80] MPT MAKE-UP",121,143,14,50.5,38.75,3.875,1.75,1.75,AT 428-4R48-Super Low Sound Fan,72,60,157.5,16.5,8400,12000,191.125,55.625,100.125,120.125,54.25,64.625,165.875,39.5,610,130.75,17