,Rev##OTHER##,W##LENGTH##INCHES,L##LENGTH##INCHES,Operating Weight##OTHER##,Remote Sump Operating Weight##OTHER##,Heaviest Section Weight##OTHER##,Shipping Weight##OTHER##,No. of Shipping Sections##OTHER##,Fan Motor Quantity##OTHER##,Fan Motor HP##OTHER##,H##LENGTH##INCHES,CSH##LENGTH##INCHES,CH##LENGTH##INCHES,CD##LENGTH##INCHES,PH##LENGTH##INCHES,PLMH##LENGTH##INCHES,LH##LENGTH##INCHES,IND##LENGTH##INCHES,INLET##OTHER##,INH##LENGTH##INCHES,DNFB##LENGTH##INCHES,DNL##LENGTH##INCHES,DND##LENGTH##INCHES,DNFS##LENGTH##INCHES,DRAIN##OTHER##,OFFS##LENGTH##INCHES,OFL##LENGTH##INCHES,OFD##LENGTH##INCHES,OFFB##LENGTH##INCHES,MUFS##LENGTH##INCHES,MUL##LENGTH##INCHES,MUFB##LENGTH##INCHES,MUD##LENGTH##INCHES,RSFB##LENGTH##INCHES,RSFC##LENGTH##INCHES,RSD##LENGTH##INCHES,RSOUTLET##OTHER##,DL##LENGTH##INCHES,DH##LENGTH##INCHES,DFT##LENGTH##INCHES,DR##LENGTH##INCHES,DFCL##LENGTH##INCHES,Model##OTHER##,(-Z) Series Flow Option Visible##OTHER##,CLR##LENGTH##INCHES,DischargeHoodWeight##OTHER##,Sound Attenuation Weight##OTHER##,SAL##LENGTH##INCHES,SACD##LENGTH##INCHES,DAL##LENGTH##INCHES,DVCL##LENGTH##INCHES,DVHT##LENGTH##INCHES,PLTFL##LENGTH##INCHES,PLTFFB##LENGTH##INCHES,PLTFW##LENGTH##INCHES,PLTFFS##LENGTH##INCHES,Platform Weight##OTHER##,LDRX##LENGTH##INCHES,SCRNH##LENGTH##INCHES,SCRNO##LENGTH##INCHES,CCX1##LENGTH##INCHES,CCX2##LENGTH##INCHES,CCX3##LENGTH##INCHES,CCX4##LENGTH##INCHES,CCYT##LENGTH##INCHES,CCYB##LENGTH##INCHES,CCL##LENGTH##INCHES,CCD##LENGTH##INCHES,PFS##LENGTH##INCHES,PFB##LENGTH##INCHES,CPD##LENGTH##INCHES,Box##OTHER##,SLL-C##LENGTH##INCHES,MH##LENGTH##INCHES,MBFT##LENGTH##INCHES
ATWB 7-3H9,2,88,107.5,10080,8910,5960,7550,2,1,7.5,136.125,48.875,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3H9,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3I9,2,88,107.5,10100,8930,5980,7570,2,1,10,136.125,48.875,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3I9,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4I9,2,88,107.5,11490,10320,7010,8600,2,1,10,143.625,56.375,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4I9,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4J9,2,88,107.5,11610,10440,7130,8720,2,1,15,143.625,56.375,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J9,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5I9,2,88,107.5,12960,11790,8110,9700,2,1,10,151.125,63.875,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5I9,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5J9,2,88,107.5,13080,11910,8230,9820,2,1,15,151.125,63.875,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J9,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-6J9,2,88,107.5,14500,13330,9290,10880,2,1,15,158.625,71.375,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6J9,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,98,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-7J9,2,88,107.5,16000,14830,10420,12010,2,1,15,164.375,77.125,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7J9,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,103.75,39.5,2.625,570,32.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3H9-Low Sound Fan,2,88,107.5,10080,8910,5960,7550,2,1,7.5,140.125,48.875,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3H9-Low Sound Fan,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3I9-Low Sound Fan,2,88,107.5,10100,8930,5980,7570,2,1,10,140.125,48.875,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3I9-Low Sound Fan,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4I9-Low Sound Fan,2,88,107.5,11490,10320,7010,8600,2,1,10,147.625,56.375,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4I9-Low Sound Fan,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4J9-Low Sound Fan,2,88,107.5,11610,10440,7130,8720,2,1,15,147.625,56.375,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J9-Low Sound Fan,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5I9-Low Sound Fan,2,88,107.5,12960,11790,8110,9700,2,1,10,155.125,63.875,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5I9-Low Sound Fan,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5J9-Low Sound Fan,2,88,107.5,13080,11910,8230,9820,2,1,15,155.125,63.875,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J9-Low Sound Fan,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-6J9-Low Sound Fan,2,88,107.5,14500,13330,9290,10880,2,1,15,162.625,71.375,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6J9-Low Sound Fan,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,98,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-7J9-Low Sound Fan,2,88,107.5,16000,14830,10420,12010,2,1,15,168.375,77.125,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7J9-Low Sound Fan,0,36,910,1640,104,55.625,75,7.25,41.875,88.875,103.75,39.5,2.625,570,32.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3H9-Super Low Sound Fan,2,88,107.5,10560,9390,6440,8030,2,1,7.5,154.125,48.875,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3H9-Super Low Sound Fan,0,36,975,1640,104,55.625,75,7.25,55.75,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3I9-Super Low Sound Fan,2,88,107.5,10580,9410,6460,8050,2,1,10,154.125,48.875,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3I9-Super Low Sound Fan,0,36,975,1640,104,55.625,75,7.25,55.75,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4I9-Super Low Sound Fan,2,88,107.5,11970,10800,7490,9080,2,1,10,161.625,56.375,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4I9-Super Low Sound Fan,0,36,975,1640,104,55.625,75,7.25,55.75,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4J9-Super Low Sound Fan,2,88,107.5,12090,10920,7610,9200,2,1,15,161.625,56.375,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J9-Super Low Sound Fan,0,36,975,1640,104,55.625,75,7.25,55.75,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5I9-Super Low Sound Fan,2,88,107.5,13440,12270,8590,10180,2,1,10,169.125,63.875,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5I9-Super Low Sound Fan,0,36,975,1640,104,55.625,75,7.25,55.75,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5J9-Super Low Sound Fan,2,88,107.5,13560,12390,8710,10300,2,1,15,169.125,63.875,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J9-Super Low Sound Fan,0,36,975,1640,104,55.625,75,7.25,55.75,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-6J9-Super Low Sound Fan,2,88,107.5,14980,13810,9770,11360,2,1,15,176.625,71.375,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6J9-Super Low Sound Fan,0,36,975,1640,104,55.625,75,7.25,55.75,88.875,98,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-7J9-Super Low Sound Fan,2,88,107.5,16480,15310,10900,12490,2,1,15,182.375,77.125,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7J9-Super Low Sound Fan,0,36,975,1640,104,55.625,75,7.25,55.75,88.875,103.75,39.5,2.625,570,32.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3J12,2,88,143.75,12760,11150,7370,9270,2,1,15,136.125,48.875,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J12,0,36,1055,1640,104,55.625,83,21,41.875,88.875,75.5,39.5,15.625,570,40.625,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-4J12,2,88,143.75,14650,13040,8770,10670,2,1,15,143.625,56.375,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J12,0,36,1055,1640,104,55.625,83,21,41.875,88.875,83,39.5,15.625,570,43.75,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5J12,2,88,143.75,16520,14910,10150,12050,2,1,15,151.125,63.875,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J12,0,36,1055,1640,104,55.625,83,21,41.875,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5K12,2,88,143.75,16580,14970,10210,12110,2,1,20,151.125,63.875,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K12,0,36,1055,1640,104,55.625,83,21,41.875,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-6K12,2,88,143.75,18490,16880,11630,13530,2,1,20,158.625,71.375,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K12,0,36,1055,1640,104,55.625,83,21,41.875,88.875,98,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-7K12,2,88,143.75,20400,18790,13050,14950,2,1,20,164.375,77.125,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7K12,0,36,1055,1640,104,55.625,83,21,41.875,88.875,103.75,39.5,15.625,570,49.875,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-3J12-Low Sound Fan,2,88,143.75,12760,11150,7370,9270,2,1,15,140.125,48.875,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J12-Low Sound Fan,0,36,1055,1640,104,55.625,83,21,41.875,88.875,75.5,39.5,15.625,570,40.625,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-4J12-Low Sound Fan,2,88,143.75,14650,13040,8770,10670,2,1,15,147.625,56.375,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J12-Low Sound Fan,0,36,1055,1640,104,55.625,83,21,41.875,88.875,83,39.5,15.625,570,43.75,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5J12-Low Sound Fan,2,88,143.75,16520,14910,10150,12050,2,1,15,155.125,63.875,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J12-Low Sound Fan,0,36,1055,1640,104,55.625,83,21,41.875,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5K12-Low Sound Fan,2,88,143.75,16580,14970,10210,12110,2,1,20,155.125,63.875,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K12-Low Sound Fan,0,36,1055,1640,104,55.625,83,21,41.875,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-6K12-Low Sound Fan,2,88,143.75,18490,16880,11630,13530,2,1,20,162.625,71.375,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K12-Low Sound Fan,0,36,1055,1640,104,55.625,83,21,41.875,88.875,98,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-7K12-Low Sound Fan,2,88,143.75,20400,18790,13050,14950,2,1,20,168.375,77.125,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7K12-Low Sound Fan,0,36,1055,1640,104,55.625,83,21,41.875,88.875,103.75,39.5,15.625,570,49.875,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-3J12-Super Low Sound Fan,2,88,143.75,13300,11690,7910,9810,2,1,15,154.125,48.875,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J12-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,21,55.75,88.875,75.5,39.5,15.625,570,40.625,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-4J12-Super Low Sound Fan,2,88,143.75,15190,13580,9310,11210,2,1,15,161.625,56.375,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J12-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,21,55.75,88.875,83,39.5,15.625,570,43.75,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5J12-Super Low Sound Fan,2,88,143.75,17060,15450,10690,12590,2,1,15,169.125,63.875,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J12-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,21,55.75,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5K12-Super Low Sound Fan,2,88,143.75,17120,15510,10750,12650,2,1,20,169.125,63.875,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K12-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,21,55.75,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-6K12-Super Low Sound Fan,2,88,143.75,19030,17420,12170,14070,2,1,20,176.625,71.375,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K12-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,21,55.75,88.875,98,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-7K12-Super Low Sound Fan,2,88,143.75,20940,19330,13590,15490,2,1,20,182.375,77.125,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7K12-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,21,55.75,88.875,103.75,39.5,15.625,570,49.875,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-3J14,2,88,167.75,14570,12760,8380,10570,2,1,15,140.5,48.875,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J14,0,36,1055,1640,104,55.625,83,33,41.875,88.875,79.875,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-4J14,2,88,167.75,16760,14950,9990,12180,2,1,15,148,56.375,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J14,0,36,1055,1640,104,55.625,83,33,41.875,88.875,87.375,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5J14,2,88,167.75,18990,17180,11650,13840,2,1,15,155.5,63.875,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J14,0,36,1055,1640,104,55.625,83,33,41.875,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5K14,2,88,167.75,19050,17240,11710,13900,2,1,20,155.5,63.875,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K14,0,36,1055,1640,104,55.625,83,33,41.875,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6K14,2,88,167.75,21270,19460,13360,15550,2,1,20,163,71.375,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K14,0,36,1055,1640,104,55.625,83,33,41.875,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6L14,2,88,167.75,21300,19490,13390,15580,2,1,25,163,71.375,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6L14,0,36,1055,1640,104,55.625,83,33,41.875,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-7L14,2,88,167.75,21910,20100,13420,15610,2,1,25,168.75,77.125,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7L14,0,36,1055,1640,104,55.625,83,33,41.875,88.875,108.125,39.5,27.625,570,65.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-3J14-Low Sound Fan,2,88,167.75,14570,12760,8380,10570,2,1,15,144.5,48.875,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J14-Low Sound Fan,0,36,1055,1640,104,55.625,83,33,41.875,88.875,79.875,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-4J14-Low Sound Fan,2,88,167.75,16760,14950,9990,12180,2,1,15,152,56.375,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J14-Low Sound Fan,0,36,1055,1640,104,55.625,83,33,41.875,88.875,87.375,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5J14-Low Sound Fan,2,88,167.75,18990,17180,11650,13840,2,1,15,159.5,63.875,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J14-Low Sound Fan,0,36,1055,1640,104,55.625,83,33,41.875,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5K14-Low Sound Fan,2,88,167.75,19050,17240,11710,13900,2,1,20,159.5,63.875,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K14-Low Sound Fan,0,36,1055,1640,104,55.625,83,33,41.875,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6K14-Low Sound Fan,2,88,167.75,21270,19460,13360,15550,2,1,20,167,71.375,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K14-Low Sound Fan,0,36,1055,1640,104,55.625,83,33,41.875,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6L14-Low Sound Fan,2,88,167.75,21300,19490,13390,15580,2,1,25,167,71.375,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6L14-Low Sound Fan,0,36,1055,1640,104,55.625,83,33,41.875,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-7L14-Low Sound Fan,2,88,167.75,21910,20100,13420,15610,2,1,25,172.625,77.125,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7L14-Low Sound Fan,0,36,1055,1640,104,55.625,83,33,41.875,88.875,108.125,39.5,27.625,570,65.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-3J14-Super Low Sound Fan,2,88,167.75,15120,13310,8930,11120,2,1,15,158.5,48.875,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J14-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,33,55.75,88.875,79.875,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-4J14-Super Low Sound Fan,2,88,167.75,17310,15500,10540,12730,2,1,15,166,56.375,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J14-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,33,55.75,88.875,87.375,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5J14-Super Low Sound Fan,2,88,167.75,19540,17730,12200,14390,2,1,15,173.5,63.875,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J14-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,33,55.75,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5K14-Super Low Sound Fan,2,88,167.75,19600,17790,12260,14450,2,1,20,173.5,63.875,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K14-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,33,55.75,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6K14-Super Low Sound Fan,2,88,167.75,21820,20010,13910,16100,2,1,20,181,71.375,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K14-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,33,55.75,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6L14-Super Low Sound Fan,2,88,167.75,21850,20040,13940,16130,2,1,25,181,71.375,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6L14-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,33,55.75,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-7L14-Super Low Sound Fan,2,88,167.75,22460,20650,13970,16160,2,1,25,186.625,77.125,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7L14-Super Low Sound Fan,0,36,1150,1640,104,55.625,83,33,55.75,88.875,108.125,39.5,27.625,570,65.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 8-3G9,2,94,107.5,11340,10110,6230,7630,2,1,5,135.375,30.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3G9,0,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3H9,2,94,107.5,11390,10160,6280,7680,2,1,7.5,135.375,30.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H9,0,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3I9,2,94,107.5,11400,10170,6290,7690,2,1,10,135.375,30.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I9,0,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3J9,2,94,107.5,11530,10300,6420,7820,2,1,15,135.375,30.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J9,0,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4G9,2,94,107.5,12820,11590,7320,8720,2,1,5,142.875,38.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4G9,0,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4H9,2,94,107.5,12870,11640,7370,8770,2,1,7.5,142.875,38.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H9,0,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4I9,2,94,107.5,12880,11650,7380,8780,2,1,10,142.875,38.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I9,0,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4J9,2,94,107.5,13010,11780,7510,8910,2,1,15,142.875,38.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J9,0,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4K9,2,94,107.5,13070,11840,7570,8970,2,1,20,142.875,38.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K9,0,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5G9,2,94,107.5,14370,13140,8480,9880,2,1,5,150.375,45.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5G9,0,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5H9,2,94,107.5,14420,13190,8530,9930,2,1,7.5,150.375,45.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H9,0,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5I9,2,94,107.5,14430,13200,8540,9940,2,1,10,150.375,45.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I9,0,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5J9,2,94,107.5,14560,13330,8670,10070,2,1,15,150.375,45.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J9,0,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5K9,2,94,107.5,14620,13390,8730,10130,2,1,20,150.375,45.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K9,0,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6G9,2,94,107.5,15910,14680,9640,11040,2,1,5,157.875,53.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6G9,0,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6H9,2,94,107.5,15960,14730,9690,11090,2,1,7.5,157.875,53.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H9,0,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6I9,2,94,107.5,15970,14740,9700,11100,2,1,10,157.875,53.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I9,0,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6J9,2,94,107.5,16100,14870,9830,11230,2,1,15,157.875,53.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J9,0,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6K9,2,94,107.5,16160,14930,9890,11290,2,1,20,157.875,53.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K9,0,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7G9,2,94,107.5,17540,16310,10880,12280,2,1,5,163.625,58.875,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7G9,0,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7H9,2,94,107.5,17590,16360,10930,12330,2,1,7.5,163.625,58.875,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H9,0,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7I9,2,94,107.5,17600,16370,10940,12340,2,1,10,163.625,58.875,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I9,0,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7J9,2,94,107.5,17730,16500,11070,12470,2,1,15,163.625,58.875,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J9,0,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7K9,2,94,107.5,17790,16560,11130,12530,2,1,20,163.625,58.875,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K9,0,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3G9-Low Sound Fan,2,94,107.5,11340,10110,6230,7630,2,1,5,139.375,30.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3G9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3H9-Low Sound Fan,2,94,107.5,11390,10160,6280,7680,2,1,7.5,139.375,30.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3I9-Low Sound Fan,2,94,107.5,11400,10170,6290,7690,2,1,10,139.375,30.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3J9-Low Sound Fan,2,94,107.5,11530,10300,6420,7820,2,1,15,139.375,30.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4G9-Low Sound Fan,2,94,107.5,12820,11590,7320,8720,2,1,5,146.875,38.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4G9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4H9-Low Sound Fan,2,94,107.5,12870,11640,7370,8770,2,1,7.5,146.875,38.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4I9-Low Sound Fan,2,94,107.5,12880,11650,7380,8780,2,1,10,146.875,38.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4J9-Low Sound Fan,2,94,107.5,13010,11780,7510,8910,2,1,15,146.875,38.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4K9-Low Sound Fan,2,94,107.5,13070,11840,7570,8970,2,1,20,146.875,38.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5G9-Low Sound Fan,2,94,107.5,14370,13140,8480,9880,2,1,5,154.375,45.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5G9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5H9-Low Sound Fan,2,94,107.5,14420,13190,8530,9930,2,1,7.5,154.375,45.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5I9-Low Sound Fan,2,94,107.5,14430,13200,8540,9940,2,1,10,154.375,45.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5J9-Low Sound Fan,2,94,107.5,14560,13330,8670,10070,2,1,15,154.375,45.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5K9-Low Sound Fan,2,94,107.5,14620,13390,8730,10130,2,1,20,154.375,45.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6G9-Low Sound Fan,2,94,107.5,15910,14680,9640,11040,2,1,5,161.875,53.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6G9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6H9-Low Sound Fan,2,94,107.5,15960,14730,9690,11090,2,1,7.5,161.875,53.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6I9-Low Sound Fan,2,94,107.5,15970,14740,9700,11100,2,1,10,161.875,53.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6J9-Low Sound Fan,2,94,107.5,16100,14870,9830,11230,2,1,15,161.875,53.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6K9-Low Sound Fan,2,94,107.5,16160,14930,9890,11290,2,1,20,161.875,53.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7G9-Low Sound Fan,2,94,107.5,17540,16310,10880,12280,2,1,5,167.625,58.875,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7G9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7H9-Low Sound Fan,2,94,107.5,17590,16360,10930,12330,2,1,7.5,167.625,58.875,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7I9-Low Sound Fan,2,94,107.5,17600,16370,10940,12340,2,1,10,167.625,58.875,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7J9-Low Sound Fan,2,94,107.5,17730,16500,11070,12470,2,1,15,167.625,58.875,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7K9-Low Sound Fan,2,94,107.5,17790,16560,11130,12530,2,1,20,167.625,58.875,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K9-Low Sound Fan,0,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3G9-Super Low Sound Fan,2,94,107.5,11940,10710,6830,8230,2,1,5,152.375,30.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3G9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3H9-Super Low Sound Fan,2,94,107.5,11990,10760,6880,8280,2,1,7.5,152.375,30.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3I9-Super Low Sound Fan,2,94,107.5,12000,10770,6890,8290,2,1,10,152.375,30.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3J9-Super Low Sound Fan,2,94,107.5,12130,10900,7020,8420,2,1,15,152.375,30.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4G9-Super Low Sound Fan,2,94,107.5,13420,12190,7920,9320,2,1,5,159.875,38.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4G9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4H9-Super Low Sound Fan,2,94,107.5,13470,12240,7970,9370,2,1,7.5,159.875,38.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4I9-Super Low Sound Fan,2,94,107.5,13480,12250,7980,9380,2,1,10,159.875,38.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4J9-Super Low Sound Fan,2,94,107.5,13610,12380,8110,9510,2,1,15,159.875,38.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4K9-Super Low Sound Fan,2,94,107.5,13670,12440,8170,9570,2,1,20,159.875,38.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5G9-Super Low Sound Fan,2,94,107.5,14970,13740,9080,10480,2,1,5,167.375,45.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5G9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5H9-Super Low Sound Fan,2,94,107.5,15020,13790,9130,10530,2,1,7.5,167.375,45.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5I9-Super Low Sound Fan,2,94,107.5,15030,13800,9140,10540,2,1,10,167.375,45.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5J9-Super Low Sound Fan,2,94,107.5,15160,13930,9270,10670,2,1,15,167.375,45.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5K9-Super Low Sound Fan,2,94,107.5,15220,13990,9330,10730,2,1,20,174.875,45.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6G9-Super Low Sound Fan,2,94,107.5,16510,15280,10240,11640,2,1,5,174.875,53.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6G9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6H9-Super Low Sound Fan,2,94,107.5,16560,15330,10290,11690,2,1,7.5,174.875,53.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6I9-Super Low Sound Fan,2,94,107.5,16570,15340,10300,11700,2,1,10,174.875,53.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6J9-Super Low Sound Fan,2,94,107.5,16700,15470,10430,11830,2,1,15,174.875,53.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6K9-Super Low Sound Fan,2,94,107.5,16760,15530,10490,11890,2,1,20,180.625,53.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7G9-Super Low Sound Fan,2,94,107.5,18140,16910,11480,12880,2,1,5,180.625,58.875,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7G9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7H9-Super Low Sound Fan,2,94,107.5,18190,16960,11530,12930,2,1,7.5,180.625,58.875,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7I9-Super Low Sound Fan,2,94,107.5,18200,16970,11540,12940,2,1,10,180.625,58.875,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7J9-Super Low Sound Fan,2,94,107.5,18330,17100,11670,13070,2,1,15,180.625,58.875,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7K9-Super Low Sound Fan,2,94,107.5,18390,17160,11730,13130,2,1,20,180.625,58.875,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K9-Super Low Sound Fan,0,36,975,1700,104,55.625,75,14.25,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3H11,2,94,125.5,13200,11750,7240,8840,2,1,7.5,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3I11,2,94,125.5,13220,11770,7260,8860,2,1,10,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3J11,2,94,125.5,13340,11890,7380,8980,2,1,15,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3K11,2,94,125.5,13400,11950,7440,9040,2,1,20,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4H11,2,94,125.5,14910,13460,8500,10100,2,1,7.5,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4I11,2,94,125.5,14930,13480,8520,10120,2,1,10,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4J11,2,94,125.5,15050,13600,8640,10240,2,1,15,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4K11,2,94,125.5,15110,13660,8700,10300,2,1,20,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5H11,2,94,125.5,16730,15280,9860,11460,2,1,7.5,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5I11,2,94,125.5,16750,15300,9880,11480,2,1,10,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5J11,2,94,125.5,16870,15420,10000,11600,2,1,15,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5K11,2,94,125.5,16930,15480,10060,11660,2,1,20,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6H11,2,94,125.5,18520,17070,11200,12800,2,1,7.5,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6I11,2,94,125.5,18540,17090,11220,12820,2,1,10,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6J11,2,94,125.5,18660,17210,11340,12940,2,1,15,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6K11,2,94,125.5,18720,17270,11400,13000,2,1,20,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7H11,2,94,125.5,20430,18980,12660,14260,2,1,7.5,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7I11,2,94,125.5,20450,19000,12680,14280,2,1,10,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7J11,2,94,125.5,20570,19120,12800,14400,2,1,15,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7K11,2,94,125.5,20630,19180,12860,14460,2,1,20,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K11,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3H11-Low Sound Fan,2,94,125.5,13200,11750,7240,8840,2,1,7.5,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3I11-Low Sound Fan,2,94,125.5,13220,11770,7260,8860,2,1,10,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3J11-Low Sound Fan,2,94,125.5,13340,11890,7380,8980,2,1,15,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3K11-Low Sound Fan,2,94,125.5,13400,11950,7440,9040,2,1,20,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4H11-Low Sound Fan,2,94,125.5,14910,13460,8500,10100,2,1,7.5,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4I11-Low Sound Fan,2,94,125.5,14930,13480,8520,10120,2,1,10,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4J11-Low Sound Fan,2,94,125.5,15050,13600,8640,10240,2,1,15,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4K11-Low Sound Fan,2,94,125.5,15110,13660,8700,10300,2,1,20,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5H11-Low Sound Fan,2,94,125.5,16730,15280,9860,11460,2,1,7.5,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5I11-Low Sound Fan,2,94,125.5,16750,15300,9880,11480,2,1,10,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5J11-Low Sound Fan,2,94,125.5,16870,15420,10000,11600,2,1,15,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5K11-Low Sound Fan,2,94,125.5,16930,15480,10060,11660,2,1,20,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6H11-Low Sound Fan,2,94,125.5,18520,17070,11200,12800,2,1,7.5,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6I11-Low Sound Fan,2,94,125.5,18540,17090,11220,12820,2,1,10,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6J11-Low Sound Fan,2,94,125.5,18660,17210,11340,12940,2,1,15,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6K11-Low Sound Fan,2,94,125.5,18720,17270,11400,13000,2,1,20,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7H11-Low Sound Fan,2,94,125.5,20430,18980,12660,14260,2,1,7.5,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7I11-Low Sound Fan,2,94,125.5,20450,19000,12680,14280,2,1,10,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7J11-Low Sound Fan,2,94,125.5,20570,19120,12800,14400,2,1,15,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7K11-Low Sound Fan,2,94,125.5,20630,19180,12860,14460,2,1,20,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K11-Low Sound Fan,0,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3H11-Super Low Sound Fan,2,94,125.5,13820,12370,7860,9460,2,1,7.5,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3I11-Super Low Sound Fan,2,94,125.5,13840,12390,7880,9480,2,1,10,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3J11-Super Low Sound Fan,2,94,125.5,13960,12510,8000,9600,2,1,15,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3K11-Super Low Sound Fan,2,94,125.5,14020,12570,8060,9660,2,1,20,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4H11-Super Low Sound Fan,2,94,125.5,15530,14080,9120,10720,2,1,7.5,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4I11-Super Low Sound Fan,2,94,125.5,15550,14100,9140,10740,2,1,10,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4J11-Super Low Sound Fan,2,94,125.5,15670,14220,9260,10860,2,1,15,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4K11-Super Low Sound Fan,2,94,125.5,15730,14280,9320,10920,2,1,20,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5H11-Super Low Sound Fan,2,94,125.5,17350,15900,10480,12080,2,1,7.5,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5I11-Super Low Sound Fan,2,94,125.5,17370,15920,10500,12100,2,1,10,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5J11-Super Low Sound Fan,2,94,125.5,17490,16040,10620,12220,2,1,15,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5K11-Super Low Sound Fan,2,94,125.5,17550,16100,10680,12280,2,1,20,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6H11-Super Low Sound Fan,2,94,125.5,19140,17690,11820,13420,2,1,7.5,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6I11-Super Low Sound Fan,2,94,125.5,19160,17710,11840,13440,2,1,10,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6J11-Super Low Sound Fan,2,94,125.5,19280,17830,11960,13560,2,1,15,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6K11-Super Low Sound Fan,2,94,125.5,19340,17890,12020,13620,2,1,20,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7H11-Super Low Sound Fan,2,94,125.5,21050,19600,13280,14880,2,1,7.5,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7I11-Super Low Sound Fan,2,94,125.5,21070,19620,13300,14900,2,1,10,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7J11-Super Low Sound Fan,2,94,125.5,21190,19740,13420,15020,2,1,15,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7K11-Super Low Sound Fan,2,94,125.5,21250,19800,13480,15080,2,1,20,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K11-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,14.25,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3H12,2,94,143.75,14600,12970,7770,9540,2,1,7.5,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3I12,2,94,143.75,14620,12990,7790,9560,2,1,10,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3J12,2,94,143.75,14740,13110,7910,9680,2,1,15,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3K12,2,94,143.75,14800,13170,7970,9740,2,1,20,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4H12,2,94,143.75,16590,14960,9240,11010,2,1,7.5,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4I12,2,94,143.75,16610,14980,9260,11030,2,1,10,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4J12,2,94,143.75,16730,15100,9380,11150,2,1,15,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4K12,2,94,143.75,16790,15160,9440,11210,2,1,20,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4L12,2,94,143.75,16820,15190,9470,11240,2,1,25,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5H12,2,94,143.75,18580,16950,10710,12480,2,1,7.5,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5I12,2,94,143.75,18600,16970,10730,12500,2,1,10,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5J12,2,94,143.75,18720,17090,10850,12620,2,1,15,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5K12,2,94,143.75,18780,17150,10910,12680,2,1,20,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5L12,2,94,143.75,18810,17180,10940,12710,2,1,25,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6H12,2,94,143.75,20650,19020,12260,14030,2,1,7.5,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6I12,2,94,143.75,20670,19040,12280,14050,2,1,10,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6J12,2,94,143.75,20790,19160,12400,14170,2,1,15,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6K12,2,94,143.75,20850,19220,12460,14230,2,1,20,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6L12,2,94,143.75,20880,19250,12490,14260,2,1,25,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7H12,2,94,143.75,22770,21140,13870,15640,2,1,7.5,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7I12,2,94,143.75,22790,21160,13890,15660,2,1,10,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7J12,2,94,143.75,22910,21280,14010,15780,2,1,15,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7K12,2,94,143.75,22970,21340,14070,15840,2,1,20,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7L12,2,94,143.75,23000,21370,14100,15870,2,1,25,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L12,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3H12-Low Sound Fan,2,94,143.75,14600,12970,7770,9540,2,1,7.5,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3I12-Low Sound Fan,2,94,143.75,14620,12990,7790,9560,2,1,10,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3J12-Low Sound Fan,2,94,143.75,14740,13110,7910,9680,2,1,15,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3K12-Low Sound Fan,2,94,143.75,14800,13170,7970,9740,2,1,20,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4H12-Low Sound Fan,2,94,143.75,16590,14960,9240,11010,2,1,7.5,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4I12-Low Sound Fan,2,94,143.75,16610,14980,9260,11030,2,1,10,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4J12-Low Sound Fan,2,94,143.75,16730,15100,9380,11150,2,1,15,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4K12-Low Sound Fan,2,94,143.75,16790,15160,9440,11210,2,1,20,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4L12-Low Sound Fan,2,94,143.75,16820,15190,9470,11240,2,1,25,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5H12-Low Sound Fan,2,94,143.75,18580,16950,10710,12480,2,1,7.5,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5I12-Low Sound Fan,2,94,143.75,18600,16970,10730,12500,2,1,10,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5J12-Low Sound Fan,2,94,143.75,18720,17090,10850,12620,2,1,15,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5K12-Low Sound Fan,2,94,143.75,18780,17150,10910,12680,2,1,20,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5L12-Low Sound Fan,2,94,143.75,18810,17180,10940,12710,2,1,25,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6H12-Low Sound Fan,2,94,143.75,20650,19020,12260,14030,2,1,7.5,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6I12-Low Sound Fan,2,94,143.75,20670,19040,12280,14050,2,1,10,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6J12-Low Sound Fan,2,94,143.75,20790,19160,12400,14170,2,1,15,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6K12-Low Sound Fan,2,94,143.75,20850,19220,12460,14230,2,1,20,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6L12-Low Sound Fan,2,94,143.75,20880,19250,12490,14260,2,1,25,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7H12-Low Sound Fan,2,94,143.75,22770,21140,13870,15640,2,1,7.5,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7I12-Low Sound Fan,2,94,143.75,22790,21160,13890,15660,2,1,10,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7J12-Low Sound Fan,2,94,143.75,22910,21280,14010,15780,2,1,15,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7K12-Low Sound Fan,2,94,143.75,22970,21340,14070,15840,2,1,20,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7L12-Low Sound Fan,2,94,143.75,23000,21370,14100,15870,2,1,25,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L12-Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3H12-Super Low Sound Fan,2,94,143.75,15320,13690,8490,10260,2,1,7.5,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3I12-Super Low Sound Fan,2,94,143.75,15340,13710,8510,10280,2,1,10,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3J12-Super Low Sound Fan,2,94,143.75,15460,13830,8630,10400,2,1,15,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3K12-Super Low Sound Fan,2,94,143.75,15520,13890,8690,10460,2,1,20,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4H12-Super Low Sound Fan,2,94,143.75,17310,15680,9960,11730,2,1,7.5,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4I12-Super Low Sound Fan,2,94,143.75,17330,15700,9980,11750,2,1,10,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4J12-Super Low Sound Fan,2,94,143.75,17450,15820,10100,11870,2,1,15,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4K12-Super Low Sound Fan,2,94,143.75,17510,15880,10160,11930,2,1,20,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4L12-Super Low Sound Fan,2,94,143.75,17540,15910,10190,11960,2,1,25,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5H12-Super Low Sound Fan,2,94,143.75,19300,17670,11430,13200,2,1,7.5,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5I12-Super Low Sound Fan,2,94,143.75,19320,17690,11450,13220,2,1,10,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5J12-Super Low Sound Fan,2,94,143.75,19440,17810,11570,13340,2,1,15,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5K12-Super Low Sound Fan,2,94,143.75,19500,17870,11630,13400,2,1,20,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5L12-Super Low Sound Fan,2,94,143.75,19530,17900,11660,13430,2,1,25,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6H12-Super Low Sound Fan,2,94,143.75,21370,19740,12980,14750,2,1,7.5,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6I12-Super Low Sound Fan,2,94,143.75,21390,19760,13000,14770,2,1,10,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6J12-Super Low Sound Fan,2,94,143.75,21510,19880,13120,14890,2,1,15,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6K12-Super Low Sound Fan,2,94,143.75,21570,19940,13180,14950,2,1,20,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6L12-Super Low Sound Fan,2,94,143.75,21600,19970,13210,14980,2,1,25,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7H12-Super Low Sound Fan,2,94,143.75,23490,21860,14590,16360,2,1,7.5,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7I12-Super Low Sound Fan,2,94,143.75,23510,21880,14610,16380,2,1,10,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7J12-Super Low Sound Fan,2,94,143.75,23630,22000,14730,16500,2,1,15,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7K12-Super Low Sound Fan,2,94,143.75,23690,22060,14790,16560,2,1,20,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7L12-Super Low Sound Fan,2,94,143.75,23720,22090,14820,16590,2,1,25,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L12-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,23.375,52,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3I14,2,94,167.75,16660,14790,8810,10780,2,1,10,139.75,30.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3J14,2,94,167.75,16780,14910,8930,10900,2,1,15,139.75,30.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3K14,2,94,167.75,16840,14970,8990,10960,2,1,20,139.75,30.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3L14,2,94,167.75,16870,15000,9020,10990,2,1,25,139.75,30.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3L14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4I14,2,94,167.75,18970,17100,10510,12480,2,1,10,147.25,38.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4J14,2,94,167.75,19090,17220,10630,12600,2,1,15,147.25,38.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4K14,2,94,167.75,19150,17280,10690,12660,2,1,20,147.25,38.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4L14,2,94,167.75,19180,17310,10720,12690,2,1,25,147.25,38.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4M14,2,94,167.75,19230,17360,10770,12740,2,1,30,147.25,38.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4M14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5I14,2,94,167.75,21280,19410,12210,14180,2,1,10,154.75,45.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5J14,2,94,167.75,21400,19530,12330,14300,2,1,15,154.75,45.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5K14,2,94,167.75,21460,19590,12390,14360,2,1,20,154.75,45.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5L14,2,94,167.75,21490,19620,12420,14390,2,1,25,154.75,45.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5M14,2,94,167.75,21540,19670,12470,14440,2,1,30,154.75,45.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5M14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6I14,2,94,167.75,23670,21800,14000,15970,2,1,10,162.25,53.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6J14,2,94,167.75,23790,21920,14120,16090,2,1,15,162.25,53.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6K14,2,94,167.75,23850,21980,14180,16150,2,1,20,162.25,53.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6L14,2,94,167.75,23880,22010,14210,16180,2,1,25,162.25,53.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6M14,2,94,167.75,23930,22060,14260,16230,2,1,30,162.25,53.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6M14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7I14,2,94,167.75,26150,24280,15870,17840,2,1,10,168,58.875,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7J14,2,94,167.75,26270,24400,15990,17960,2,1,15,168,58.875,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7K14,2,94,167.75,26330,24460,16050,18020,2,1,20,168,58.875,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7L14,2,94,167.75,26360,24490,16080,18050,2,1,25,168,58.875,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7M14,2,94,167.75,26410,24540,16130,18100,2,1,30,168,58.875,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7M14,0,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3I14-Low Sound Fan,2,94,167.75,16660,14790,8810,10780,2,1,10,143.75,30.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3J14-Low Sound Fan,2,94,167.75,16780,14910,8930,10900,2,1,15,143.75,30.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3K14-Low Sound Fan,2,94,167.75,16840,14970,8990,10960,2,1,20,143.75,30.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3L14-Low Sound Fan,2,94,167.75,16870,15000,9020,10990,2,1,25,143.75,30.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3L14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4I14-Low Sound Fan,2,94,167.75,18970,17100,10510,12480,2,1,10,151.25,38.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4J14-Low Sound Fan,2,94,167.75,19090,17220,10630,12600,2,1,15,151.25,38.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4K14-Low Sound Fan,2,94,167.75,19150,17280,10690,12660,2,1,20,151.25,38.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4L14-Low Sound Fan,2,94,167.75,19180,17310,10720,12690,2,1,25,151.25,38.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4M14-Low Sound Fan,2,94,167.75,19230,17360,10770,12740,2,1,30,151.25,38.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4M14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5I14-Low Sound Fan,2,94,167.75,21280,19410,12210,14180,2,1,10,158.75,45.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5J14-Low Sound Fan,2,94,167.75,21400,19530,12330,14300,2,1,15,158.75,45.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5K14-Low Sound Fan,2,94,167.75,21460,19590,12390,14360,2,1,20,158.75,45.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5L14-Low Sound Fan,2,94,167.75,21490,19620,12420,14390,2,1,25,158.75,45.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5M14-Low Sound Fan,2,94,167.75,21540,19670,12470,14440,2,1,30,158.75,45.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5M14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6I14-Low Sound Fan,2,94,167.75,23670,21800,14000,15970,2,1,10,166.25,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6J14-Low Sound Fan,2,94,167.75,23790,21920,14120,16090,2,1,15,166.25,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6K14-Low Sound Fan,2,94,167.75,23850,21980,14180,16150,2,1,20,166.25,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6L14-Low Sound Fan,2,94,167.75,23880,22010,14210,16180,2,1,25,166.25,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6M14-Low Sound Fan,2,94,167.75,23930,22060,14260,16230,2,1,30,166.25,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6M14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7I14-Low Sound Fan,2,94,167.75,26150,24280,15870,17840,2,1,10,172,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7J14-Low Sound Fan,2,94,167.75,26270,24400,15990,17960,2,1,15,172,58.875,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7K14-Low Sound Fan,2,94,167.75,26330,24460,16050,18020,2,1,20,172,58.875,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7L14-Low Sound Fan,2,94,167.75,26360,24490,16080,18050,2,1,25,172,58.875,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7M14-Low Sound Fan,2,94,167.75,26410,24540,16130,18100,2,1,30,172,58.875,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7M14-Low Sound Fan,0,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3I14-Super Low Sound Fan,2,94,167.75,17390,15520,9540,11510,2,1,10,156.75,30.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3J14-Super Low Sound Fan,2,94,167.75,17510,15640,9660,11630,2,1,15,156.75,30.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3K14-Super Low Sound Fan,2,94,167.75,17570,15700,9720,11690,2,1,20,156.75,30.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3L14-Super Low Sound Fan,2,94,167.75,17600,15730,9750,11720,2,1,25,156.75,30.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3L14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4I14-Super Low Sound Fan,2,94,167.75,19700,17830,11240,13210,2,1,10,164.25,38.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4J14-Super Low Sound Fan,2,94,167.75,19820,17950,11360,13330,2,1,15,164.25,38.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4K14-Super Low Sound Fan,2,94,167.75,19880,18010,11420,13390,2,1,20,164.25,38.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4L14-Super Low Sound Fan,2,94,167.75,19910,18040,11450,13420,2,1,25,164.25,38.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4M14-Super Low Sound Fan,2,94,167.75,19960,18090,11500,13470,2,1,30,164.25,38.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4M14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5I14-Super Low Sound Fan,2,94,167.75,22010,20140,12940,14910,2,1,10,171.75,45.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5J14-Super Low Sound Fan,2,94,167.75,22130,20260,13060,15030,2,1,15,171.75,45.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5K14-Super Low Sound Fan,2,94,167.75,22190,20320,13120,15090,2,1,20,171.75,45.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5L14-Super Low Sound Fan,2,94,167.75,22220,20350,13150,15120,2,1,25,171.75,45.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5M14-Super Low Sound Fan,2,94,167.75,22270,20400,13200,15170,2,1,30,171.75,45.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5M14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6I14-Super Low Sound Fan,2,94,167.75,24400,22530,14730,16700,2,1,10,179.25,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6J14-Super Low Sound Fan,2,94,167.75,24520,22650,14850,16820,2,1,15,179.25,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6K14-Super Low Sound Fan,2,94,167.75,24580,22710,14910,16880,2,1,20,179.25,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6L14-Super Low Sound Fan,2,94,167.75,24610,22740,14940,16910,2,1,25,179.25,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6M14-Super Low Sound Fan,2,94,167.75,24660,22790,14990,16960,2,1,30,179.25,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6M14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7I14-Super Low Sound Fan,2,94,167.75,26880,25010,16600,18570,2,1,10,185,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7J14-Super Low Sound Fan,2,94,167.75,27000,25130,16720,18690,2,1,15,185,58.875,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7K14-Super Low Sound Fan,2,94,167.75,27060,25190,16780,18750,2,1,20,185,58.875,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7L14-Super Low Sound Fan,2,94,167.75,27090,25220,16810,18780,2,1,25,185,58.875,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7M14-Super Low Sound Fan,2,94,167.75,27140,25270,16860,18830,2,1,30,185,58.875,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"6"" [150] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7M14-Super Low Sound Fan,0,36,1150,1700,104,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 9-3G8,2,89.875,101.5,10150,9050,5490,6790,2,1,5,127.25,30.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3G8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3H8,2,89.875,101.5,10200,9100,5540,6840,2,1,7.5,127.25,30.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3I8,2,89.875,101.5,10210,9110,5550,6850,2,1,10,127.25,30.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3J8,2,89.875,101.5,10340,9240,5680,6980,2,1,15,127.25,30.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4G8,2,89.875,101.5,11450,10350,6450,7750,2,1,5,134.75,38.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4G8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4H8,2,89.875,101.5,11500,10400,6500,7800,2,1,7.5,134.75,38.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4I8,2,89.875,101.5,11510,10410,6510,7810,2,1,10,134.75,38.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4J8,2,89.875,101.5,11640,10540,6640,7940,2,1,15,134.75,38.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5H8,2,89.875,101.5,12890,11790,7550,8850,2,1,7.5,142.25,45.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5I8,2,89.875,101.5,12900,11800,7560,8860,2,1,10,142.25,45.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5J8,2,89.875,101.5,13030,11930,7690,8990,2,1,15,142.25,45.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6H8,2,89.875,101.5,14270,13170,8580,9880,2,1,7.5,149.75,53.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6H8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6I8,2,89.875,101.5,14280,13180,8590,9890,2,1,10,149.75,53.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6J8,2,89.875,101.5,14410,13310,8720,10020,2,1,15,149.75,53.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7H8,2,89.875,101.5,15740,14640,9710,11010,2,1,7.5,155.5,58.875,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7H8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7I8,2,89.875,101.5,15750,14650,9720,11020,2,1,10,155.5,58.875,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7J8,2,89.875,101.5,15880,14780,9850,11150,2,1,15,155.5,58.875,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J8,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3G8-Low Sound Fan,2,89.875,101.5,10150,9050,5490,6790,2,1,5,131.25,30.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3G8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3H8-Low Sound Fan,2,89.875,101.5,10200,9100,5540,6840,2,1,7.5,131.25,30.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3I8-Low Sound Fan,2,89.875,101.5,10210,9110,5550,6850,2,1,10,131.25,30.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3J8-Low Sound Fan,2,89.875,101.5,10340,9240,5680,6980,2,1,15,131.25,30.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4G8-Low Sound Fan,2,89.875,101.5,11450,10350,6450,7750,2,1,5,138.75,38.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4G8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4H8-Low Sound Fan,2,89.875,101.5,11500,10400,6500,7800,2,1,7.5,138.75,38.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4I8-Low Sound Fan,2,89.875,101.5,11510,10410,6510,7810,2,1,10,138.75,38.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4J8-Low Sound Fan,2,89.875,101.5,11640,10540,6640,7940,2,1,15,138.75,38.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5H8-Low Sound Fan,2,89.875,101.5,12890,11790,7550,8850,2,1,7.5,146.25,45.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5I8-Low Sound Fan,2,89.875,101.5,12900,11800,7560,8860,2,1,10,146.25,45.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5J8-Low Sound Fan,2,89.875,101.5,13030,11930,7690,8990,2,1,15,146.25,45.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6H8-Low Sound Fan,2,89.875,101.5,14270,13170,8580,9880,2,1,7.5,153.75,53.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6H8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6I8-Low Sound Fan,2,89.875,101.5,14280,13180,8590,9890,2,1,10,153.75,53.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6J8-Low Sound Fan,2,89.875,101.5,14410,13310,8720,10020,2,1,15,153.75,53.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7H8-Low Sound Fan,2,89.875,101.5,15740,14640,9710,11010,2,1,7.5,159.5,58.875,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7H8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7I8-Low Sound Fan,2,89.875,101.5,15750,14650,9720,11020,2,1,10,159.5,58.875,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7J8-Low Sound Fan,2,89.875,101.5,15880,14780,9850,11150,2,1,15,159.5,58.875,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J8-Low Sound Fan,0,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3G8-Super Low Sound Fan,2,89.875,101.5,10600,9500,5940,7240,2,1,5,144.25,30.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3G8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3H8-Super Low Sound Fan,2,89.875,101.5,10650,9550,5990,7290,2,1,7.5,144.25,30.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3I8-Super Low Sound Fan,2,89.875,101.5,10660,9560,6000,7300,2,1,10,144.25,30.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3J8-Super Low Sound Fan,2,89.875,101.5,10790,9690,6130,7430,2,1,15,144.25,30.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4G8-Super Low Sound Fan,2,89.875,101.5,11900,10800,6900,8200,2,1,5,151.75,38.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4G8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4H8-Super Low Sound Fan,2,89.875,101.5,11950,10850,6950,8250,2,1,7.5,151.75,38.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4I8-Super Low Sound Fan,2,89.875,101.5,11960,10860,6960,8260,2,1,10,151.75,38.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4J8-Super Low Sound Fan,2,89.875,101.5,12090,10990,7090,8390,2,1,15,151.75,38.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5H8-Super Low Sound Fan,2,89.875,101.5,13340,12240,8000,9300,2,1,7.5,159.25,45.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5I8-Super Low Sound Fan,2,89.875,101.5,13350,12250,8010,9310,2,1,10,159.25,45.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5J8-Super Low Sound Fan,2,89.875,101.5,13480,12380,8140,9440,2,1,15,159.25,45.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6H8-Super Low Sound Fan,2,89.875,101.5,14720,13620,9030,10330,2,1,7.5,166.75,53.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6H8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6I8-Super Low Sound Fan,2,89.875,101.5,14730,13630,9040,10340,2,1,10,166.75,53.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6J8-Super Low Sound Fan,2,89.875,101.5,14860,13760,9170,10470,2,1,15,166.75,53.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7H8-Super Low Sound Fan,2,89.875,101.5,16190,15090,10160,11460,2,1,7.5,172.5,58.875,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7H8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7I8-Super Low Sound Fan,2,89.875,101.5,16200,15100,10170,11470,2,1,10,172.5,58.875,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7J8-Super Low Sound Fan,2,89.875,101.5,16330,15230,10300,11600,2,1,15,172.5,58.875,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J8-Super Low Sound Fan,0,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3H9,2,101.5,107.5,12020,10740,6600,8040,2,1,7.5,135.375,30.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H9,0,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,22.5,45.25,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3I9,2,101.5,107.5,12030,10750,6610,8050,2,1,10,135.375,30.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I9,0,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3J9,2,101.5,107.5,12160,10880,6740,8180,2,1,15,135.375,30.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J9,0,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3K9,2,101.5,107.5,12220,10940,6800,8240,2,1,20,135.375,30.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K9,0,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4H9,2,101.5,107.5,13590,12310,7750,9190,2,1,7.5,146.875,38.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H9,0,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4I9,2,101.5,107.5,13600,12320,7760,9200,2,1,10,146.875,38.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I9,0,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4J9,2,101.5,107.5,13730,12450,7890,9330,2,1,15,146.875,38.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J9,0,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4K9,2,101.5,107.5,13790,12510,7950,9390,2,1,20,146.875,38.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K9,0,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5H9,2,101.5,107.5,15270,13990,9010,10450,2,1,7.5,150.375,45.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H9,0,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5I9,2,101.5,107.5,15280,14000,9020,10460,2,1,10,150.375,45.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I9,0,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5J9,2,101.5,107.5,15410,14130,9150,10590,2,1,15,150.375,45.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J9,0,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5K9,2,101.5,107.5,15470,14190,9210,10650,2,1,20,150.375,45.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K9,0,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6I9,2,101.5,107.5,16940,15660,10260,11700,2,1,10,157.875,53.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I9,0,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6J9,2,101.5,107.5,17070,15790,10390,11830,2,1,15,157.875,53.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J9,0,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6K9,2,101.5,107.5,17130,15850,10450,11890,2,1,20,157.875,53.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K9,0,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7I9,2,101.5,107.5,18850,17570,11760,13200,2,1,10,163.625,58.875,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I9,0,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7J9,2,101.5,107.5,18980,17700,11890,13330,2,1,15,163.625,58.875,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J9,0,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7K9,2,101.5,107.5,19040,17760,11950,13390,2,1,20,163.625,58.875,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K9,0,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3H9-Low Sound Fan,2,101.5,107.5,12020,10740,6600,8040,2,1,7.5,139.375,30.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3I9-Low Sound Fan,2,101.5,107.5,12030,10750,6610,8050,2,1,10,139.375,30.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3J9-Low Sound Fan,2,101.5,107.5,12160,10880,6740,8180,2,1,15,139.375,30.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3K9-Low Sound Fan,2,101.5,107.5,12220,10940,6800,8240,2,1,20,139.375,30.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4H9-Low Sound Fan,2,101.5,107.5,13590,12310,7750,9190,2,1,7.5,150.875,38.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4I9-Low Sound Fan,2,101.5,107.5,13600,12320,7760,9200,2,1,10,150.875,38.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4J9-Low Sound Fan,2,101.5,107.5,13730,12450,7890,9330,2,1,15,150.875,38.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4K9-Low Sound Fan,2,101.5,107.5,13790,12510,7950,9390,2,1,20,154.375,38.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5H9-Low Sound Fan,2,101.5,107.5,15270,13990,9010,10450,2,1,7.5,154.375,45.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5I9-Low Sound Fan,2,101.5,107.5,15280,14000,9020,10460,2,1,10,154.375,45.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5J9-Low Sound Fan,2,101.5,107.5,15410,14130,9150,10590,2,1,15,154.375,45.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5K9-Low Sound Fan,2,101.5,107.5,15470,14190,9210,10650,2,1,20,154.375,45.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6I9-Low Sound Fan,2,101.5,107.5,16940,15660,10260,11700,2,1,10,161.875,53.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6J9-Low Sound Fan,2,101.5,107.5,17070,15790,10390,11830,2,1,15,161.875,53.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6K9-Low Sound Fan,2,101.5,107.5,17130,15850,10450,11890,2,1,20,161.875,53.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7I9-Low Sound Fan,2,101.5,107.5,18850,17570,11760,13200,2,1,10,167.625,58.875,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7J9-Low Sound Fan,2,101.5,107.5,18980,17700,11890,13330,2,1,15,167.625,58.875,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7K9-Low Sound Fan,2,101.5,107.5,19040,17760,11950,13390,2,1,20,167.625,58.875,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K9-Low Sound Fan,0,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3H9-Super Low Sound Fan,2,101.5,107.5,12740,11460,7320,8760,2,1,7.5,156.375,30.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3I9-Super Low Sound Fan,2,101.5,107.5,12750,11470,7330,8770,2,1,10,156.375,30.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3J9-Super Low Sound Fan,2,101.5,107.5,12880,11600,7460,8900,2,1,15,156.375,30.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3K9-Super Low Sound Fan,2,101.5,107.5,12940,11660,7520,8960,2,1,20,156.375,30.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4H9-Super Low Sound Fan,2,101.5,107.5,14310,13030,8470,9910,2,1,7.5,167.875,38.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4I9-Super Low Sound Fan,2,101.5,107.5,14320,13040,8480,9920,2,1,10,167.875,38.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4J9-Super Low Sound Fan,2,101.5,107.5,14450,13170,8610,10050,2,1,15,167.875,38.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4K9-Super Low Sound Fan,2,101.5,107.5,14510,13230,8670,10110,2,1,20,167.875,38.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5H9-Super Low Sound Fan,2,101.5,107.5,15990,14710,9730,11170,2,1,7.5,171.375,45.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5I9-Super Low Sound Fan,2,101.5,107.5,16000,14720,9740,11180,2,1,10,171.375,45.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5J9-Super Low Sound Fan,2,101.5,107.5,16130,14850,9870,11310,2,1,15,171.375,45.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5K9-Super Low Sound Fan,2,101.5,107.5,16190,14910,9930,11370,2,1,20,171.375,45.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6I9-Super Low Sound Fan,2,101.5,107.5,17660,16380,10980,12420,2,1,10,178.875,53.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6J9-Super Low Sound Fan,2,101.5,107.5,17790,16510,11110,12550,2,1,15,178.875,53.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6K9-Super Low Sound Fan,2,101.5,107.5,17850,16570,11170,12610,2,1,20,178.875,53.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7I9-Super Low Sound Fan,2,101.5,107.5,19570,18290,12480,13920,2,1,10,184.625,58.875,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7J9-Super Low Sound Fan,2,101.5,107.5,19700,18420,12610,14050,2,1,15,184.625,58.875,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7K9-Super Low Sound Fan,2,101.5,107.5,19760,18480,12670,14110,2,1,20,184.625,58.875,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K9-Super Low Sound Fan,0,36,1055,1800,104,55.625,75,9,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3H11,2,101.5,125.5,13920,12410,7600,9240,2,1,7.5,135.375,30.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3I11,2,101.5,125.5,13940,12430,7620,9260,2,1,10,135.375,30.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3J11,2,101.5,125.5,14060,12550,7740,9380,2,1,15,135.375,30.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3K11,2,101.5,125.5,14120,12610,7800,9440,2,1,20,135.375,30.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4H11,2,101.5,125.5,15750,14240,8940,10580,2,1,7.5,142.875,38.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4I11,2,101.5,125.5,15770,14260,8960,10600,2,1,10,142.875,38.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4J11,2,101.5,125.5,15890,14380,9080,10720,2,1,15,142.875,38.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4K11,2,101.5,125.5,15950,14440,9140,10780,2,1,20,142.875,38.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5I11,2,101.5,125.5,17760,16250,10460,12100,2,1,10,150.375,45.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5J11,2,101.5,125.5,17880,16370,10580,12220,2,1,15,150.375,45.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5K11,2,101.5,125.5,17940,16430,10640,12280,2,1,20,150.375,45.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5L11,2,101.5,125.5,17970,16460,10670,12310,2,1,25,150.375,45.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6J11,2,101.5,125.5,19790,18280,12000,13640,2,1,15,157.875,53.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6K11,2,101.5,125.5,19850,18340,12060,13700,2,1,20,157.875,53.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6L11,2,101.5,125.5,19880,18370,12090,13730,2,1,25,157.875,53.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7J11,2,101.5,125.5,22030,20520,13760,15400,2,1,15,163.625,58.875,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7K11,2,101.5,125.5,22090,20580,13820,15460,2,1,20,163.625,58.875,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7L11,2,101.5,125.5,22120,20610,13850,15490,2,1,25,163.625,58.875,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L11,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3H11-Low Sound Fan,2,101.5,125.5,13920,12410,7600,9240,2,1,7.5,139.375,30.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3I11-Low Sound Fan,2,101.5,125.5,13940,12430,7620,9260,2,1,10,139.375,30.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3J11-Low Sound Fan,2,101.5,125.5,14060,12550,7740,9380,2,1,15,139.375,30.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3K11-Low Sound Fan,2,101.5,125.5,14120,12610,7800,9440,2,1,20,139.375,30.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4H11-Low Sound Fan,2,101.5,125.5,15750,14240,8940,10580,2,1,7.5,146.875,38.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4I11-Low Sound Fan,2,101.5,125.5,15770,14260,8960,10600,2,1,10,146.875,38.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4J11-Low Sound Fan,2,101.5,125.5,15890,14380,9080,10720,2,1,15,146.875,38.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4K11-Low Sound Fan,2,101.5,125.5,15950,14440,9140,10780,2,1,20,146.875,38.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5I11-Low Sound Fan,2,101.5,125.5,17760,16250,10460,12100,2,1,10,154.375,45.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5J11-Low Sound Fan,2,101.5,125.5,17880,16370,10580,12220,2,1,15,154.375,45.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5K11-Low Sound Fan,2,101.5,125.5,17940,16430,10640,12280,2,1,20,154.375,45.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5L11-Low Sound Fan,2,101.5,125.5,17970,16460,10670,12310,2,1,25,154.375,45.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6J11-Low Sound Fan,2,101.5,125.5,19790,18280,12000,13640,2,1,15,161.875,53.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6K11-Low Sound Fan,2,101.5,125.5,19850,18340,12060,13700,2,1,20,161.875,53.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6L11-Low Sound Fan,2,101.5,125.5,19880,18370,12090,13730,2,1,25,161.875,53.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7J11-Low Sound Fan,2,101.5,125.5,22030,20520,13760,15400,2,1,15,167.625,58.875,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7K11-Low Sound Fan,2,101.5,125.5,22090,20580,13820,15460,2,1,20,167.625,58.875,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7L11-Low Sound Fan,2,101.5,125.5,22120,20610,13850,15490,2,1,25,167.625,58.875,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L11-Low Sound Fan,0,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3H11-Super Low Sound Fan,2,101.5,125.5,14650,13140,8330,9970,2,1,7.5,156.375,30.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3I11-Super Low Sound Fan,2,101.5,125.5,14670,13160,8350,9990,2,1,10,156.375,30.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3J11-Super Low Sound Fan,2,101.5,125.5,14790,13280,8470,10110,2,1,15,156.375,30.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3K11-Super Low Sound Fan,2,101.5,125.5,14850,13340,8530,10170,2,1,20,156.375,30.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4H11-Super Low Sound Fan,2,101.5,125.5,16480,14970,9670,11310,2,1,7.5,163.875,38.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4I11-Super Low Sound Fan,2,101.5,125.5,16500,14990,9690,11330,2,1,10,163.875,38.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4J11-Super Low Sound Fan,2,101.5,125.5,16620,15110,9810,11450,2,1,15,163.875,38.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4K11-Super Low Sound Fan,2,101.5,125.5,16680,15170,9870,11510,2,1,20,171.375,38.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5I11-Super Low Sound Fan,2,101.5,125.5,18490,16980,11190,12830,2,1,10,171.375,45.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5J11-Super Low Sound Fan,2,101.5,125.5,18610,17100,11310,12950,2,1,15,171.375,45.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5K11-Super Low Sound Fan,2,101.5,125.5,18670,17160,11370,13010,2,1,20,171.375,45.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5L11-Super Low Sound Fan,2,101.5,125.5,18700,17190,11400,13040,2,1,25,171.375,45.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6J11-Super Low Sound Fan,2,101.5,125.5,20520,19010,12730,14370,2,1,15,178.875,53.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6K11-Super Low Sound Fan,2,101.5,125.5,20580,19070,12790,14430,2,1,20,178.875,53.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6L11-Super Low Sound Fan,2,101.5,125.5,20610,19100,12820,14460,2,1,25,178.875,53.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7J11-Super Low Sound Fan,2,101.5,125.5,22760,21250,14490,16130,2,1,15,184.625,58.875,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7K11-Super Low Sound Fan,2,101.5,125.5,22820,21310,14550,16190,2,1,20,184.625,58.875,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7L11-Super Low Sound Fan,2,101.5,125.5,22850,21340,14580,16220,2,1,25,184.625,58.875,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L11-Super Low Sound Fan,0,36,1240,1800,104,55.625,83,14.625,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3I12,2,101.5,143.75,15380,13670,8150,9950,2,1,10,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3J12,2,101.5,143.75,15510,13800,8280,10080,2,1,15,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3K12,2,101.5,143.75,15570,13860,8340,10140,2,1,20,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3L12,2,101.5,143.75,15600,13890,8370,10170,2,1,25,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4I12,2,101.5,143.75,17510,15800,9720,11520,2,1,10,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4J12,2,101.5,143.75,17640,15930,9850,11650,2,1,15,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4K12,2,101.5,143.75,17700,15990,9910,11710,2,1,20,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4L12,2,101.5,143.75,17730,16020,9940,11740,2,1,25,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5J12,2,101.5,143.75,19790,18080,11440,13240,2,1,15,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5K12,2,101.5,143.75,19850,18140,11500,13300,2,1,20,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5L12,2,101.5,143.75,19880,18170,11530,13330,2,1,25,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5M12,2,101.5,143.75,19930,18220,11580,13380,2,1,30,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6J12,2,101.5,143.75,21980,20270,13070,14870,2,1,15,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6K12,2,101.5,143.75,22040,20330,13130,14930,2,1,20,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6L12,2,101.5,143.75,22070,20360,13160,14960,2,1,25,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6M12,2,101.5,143.75,22120,20410,13210,15010,2,1,30,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7J12,2,101.5,143.75,24480,22770,15000,16800,2,1,15,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7K12,2,101.5,143.75,24540,22830,15060,16860,2,1,20,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7L12,2,101.5,143.75,24570,22860,15090,16890,2,1,25,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7M12,2,101.5,143.75,24620,22910,15140,16940,2,1,30,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M12,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3I12-Low Sound Fan,2,101.5,143.75,15380,13670,8150,9950,2,1,10,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3J12-Low Sound Fan,2,101.5,143.75,15510,13800,8280,10080,2,1,15,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3K12-Low Sound Fan,2,101.5,143.75,15570,13860,8340,10140,2,1,20,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3L12-Low Sound Fan,2,101.5,143.75,15600,13890,8370,10170,2,1,25,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4I12-Low Sound Fan,2,101.5,143.75,17510,15800,9720,11520,2,1,10,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4J12-Low Sound Fan,2,101.5,143.75,17640,15930,9850,11650,2,1,15,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4K12-Low Sound Fan,2,101.5,143.75,17700,15990,9910,11710,2,1,20,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4L12-Low Sound Fan,2,101.5,143.75,17730,16020,9940,11740,2,1,25,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5J12-Low Sound Fan,2,101.5,143.75,19790,18080,11440,13240,2,1,15,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5K12-Low Sound Fan,2,101.5,143.75,19850,18140,11500,13300,2,1,20,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5L12-Low Sound Fan,2,101.5,143.75,19880,18170,11530,13330,2,1,25,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5M12-Low Sound Fan,2,101.5,143.75,19930,18220,11580,13380,2,1,30,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6J12-Low Sound Fan,2,101.5,143.75,21980,20270,13070,14870,2,1,15,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6K12-Low Sound Fan,2,101.5,143.75,22040,20330,13130,14930,2,1,20,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6L12-Low Sound Fan,2,101.5,143.75,22070,20360,13160,14960,2,1,25,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6M12-Low Sound Fan,2,101.5,143.75,22120,20410,13210,15010,2,1,30,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7J12-Low Sound Fan,2,101.5,143.75,24480,22770,15000,16800,2,1,15,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7K12-Low Sound Fan,2,101.5,143.75,24540,22830,15060,16860,2,1,20,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7L12-Low Sound Fan,2,101.5,143.75,24570,22860,15090,16890,2,1,25,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7M12-Low Sound Fan,2,101.5,143.75,24620,22910,15140,16940,2,1,30,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M12-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3I12-Super Low Sound Fan,2,101.5,143.75,16200,14490,8970,10770,2,1,10,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3J12-Super Low Sound Fan,2,101.5,143.75,16330,14620,9100,10900,2,1,15,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3K12-Super Low Sound Fan,2,101.5,143.75,16390,14680,9160,10960,2,1,20,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3L12-Super Low Sound Fan,2,101.5,143.75,16420,14710,9190,10990,2,1,25,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4I12-Super Low Sound Fan,2,101.5,143.75,18330,16620,10540,12340,2,1,10,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4J12-Super Low Sound Fan,2,101.5,143.75,18460,16750,10670,12470,2,1,15,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4K12-Super Low Sound Fan,2,101.5,143.75,18520,16810,10730,12530,2,1,20,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4L12-Super Low Sound Fan,2,101.5,143.75,18550,16840,10760,12560,2,1,25,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5J12-Super Low Sound Fan,2,101.5,143.75,20610,18900,12260,14060,2,1,15,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5K12-Super Low Sound Fan,2,101.5,143.75,20670,18960,12320,14120,2,1,20,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5L12-Super Low Sound Fan,2,101.5,143.75,20700,18990,12350,14150,2,1,25,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5M12-Super Low Sound Fan,2,101.5,143.75,20750,19040,12400,14200,2,1,30,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6J12-Super Low Sound Fan,2,101.5,143.75,22800,21090,13890,15690,2,1,15,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6K12-Super Low Sound Fan,2,101.5,143.75,22860,21150,13950,15750,2,1,20,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6L12-Super Low Sound Fan,2,101.5,143.75,22890,21180,13980,15780,2,1,25,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6M12-Super Low Sound Fan,2,101.5,143.75,22940,21230,14030,15830,2,1,30,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7J12-Super Low Sound Fan,2,101.5,143.75,25300,23590,15820,17620,2,1,15,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7K12-Super Low Sound Fan,2,101.5,143.75,25360,23650,15880,17680,2,1,20,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7L12-Super Low Sound Fan,2,101.5,143.75,25390,23680,15910,17710,2,1,25,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7M12-Super Low Sound Fan,2,101.5,143.75,25440,23730,15960,17760,2,1,30,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M12-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,21.625,52,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3I14,2,101.5,167.75,17550,15590,9230,11240,2,1,10,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3J14,2,101.5,167.75,17680,15720,9360,11370,2,1,15,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3K14,2,101.5,167.75,17740,15780,9420,11430,2,1,20,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3L14,2,101.5,167.75,17770,15810,9450,11460,2,1,25,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4J14,2,101.5,167.75,20160,18200,11180,13190,2,1,15,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4K14,2,101.5,167.75,20220,18260,11240,13250,2,1,20,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4L14,2,101.5,167.75,20250,18290,11270,13280,2,1,25,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4M14,2,101.5,167.75,20300,18340,11320,13330,2,1,30,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4M14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5J14,2,101.5,167.75,22650,20690,13020,15030,2,1,15,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5K14,2,101.5,167.75,22710,20750,13080,15090,2,1,20,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5L14,2,101.5,167.75,22740,20780,13110,15120,2,1,25,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5M14,2,101.5,167.75,22790,20830,13160,15170,2,1,30,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6K14,2,101.5,167.75,25280,23320,14990,17000,2,1,20,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6L14,2,101.5,167.75,25310,23350,15020,17030,2,1,25,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6M14,2,101.5,167.75,25360,23400,15070,17080,2,1,30,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7K14,2,101.5,167.75,28180,26220,17240,19250,2,1,20,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7L14,2,101.5,167.75,28210,26250,17270,19280,2,1,25,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7M14,2,101.5,167.75,28260,26300,17320,19330,2,1,30,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M14,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3I14-Low Sound Fan,2,101.5,167.75,17550,15590,9230,11240,2,1,10,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3J14-Low Sound Fan,2,101.5,167.75,17680,15720,9360,11370,2,1,15,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3K14-Low Sound Fan,2,101.5,167.75,17740,15780,9420,11430,2,1,20,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3L14-Low Sound Fan,2,101.5,167.75,17770,15810,9450,11460,2,1,25,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4J14-Low Sound Fan,2,101.5,167.75,20160,18200,11180,13190,2,1,15,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4K14-Low Sound Fan,2,101.5,167.75,20220,18260,11240,13250,2,1,20,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4L14-Low Sound Fan,2,101.5,167.75,20250,18290,11270,13280,2,1,25,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4M14-Low Sound Fan,2,101.5,167.75,20300,18340,11320,13330,2,1,30,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4M14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5J14-Low Sound Fan,2,101.5,167.75,22650,20690,13020,15030,2,1,15,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5K14-Low Sound Fan,2,101.5,167.75,22710,20750,13080,15090,2,1,20,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5L14-Low Sound Fan,2,101.5,167.75,22740,20780,13110,15120,2,1,25,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5M14-Low Sound Fan,2,101.5,167.75,22790,20830,13160,15170,2,1,30,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6K14-Low Sound Fan,2,101.5,167.75,25280,23320,14990,17000,2,1,20,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6L14-Low Sound Fan,2,101.5,167.75,25310,23350,15020,17030,2,1,25,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6M14-Low Sound Fan,2,101.5,167.75,25360,23400,15070,17080,2,1,30,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7K14-Low Sound Fan,2,101.5,167.75,28180,26220,17240,19250,2,1,20,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7L14-Low Sound Fan,2,101.5,167.75,28210,26250,17270,19280,2,1,25,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7M14-Low Sound Fan,2,101.5,167.75,28260,26300,17320,19330,2,1,30,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M14-Low Sound Fan,0,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3I14-Super Low Sound Fan,2,101.5,167.75,18420,16460,10100,12110,2,1,10,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3J14-Super Low Sound Fan,2,101.5,167.75,18550,16590,10230,12240,2,1,15,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3K14-Super Low Sound Fan,2,101.5,167.75,18610,16650,10290,12300,2,1,20,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3L14-Super Low Sound Fan,2,101.5,167.75,18640,16680,10320,12330,2,1,25,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4J14-Super Low Sound Fan,2,101.5,167.75,21030,19070,12050,14060,2,1,15,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4K14-Super Low Sound Fan,2,101.5,167.75,21090,19130,12110,14120,2,1,20,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4L14-Super Low Sound Fan,2,101.5,167.75,21120,19160,12140,14150,2,1,25,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4M14-Super Low Sound Fan,2,101.5,167.75,21170,19210,12190,14200,2,1,30,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4M14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5J14-Super Low Sound Fan,2,101.5,167.75,23520,21560,13890,15900,2,1,15,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5K14-Super Low Sound Fan,2,101.5,167.75,23580,21620,13950,15960,2,1,20,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5L14-Super Low Sound Fan,2,101.5,167.75,23610,21650,13980,15990,2,1,25,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5M14-Super Low Sound Fan,2,101.5,167.75,23660,21700,14030,16040,2,1,30,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6K14-Super Low Sound Fan,2,101.5,167.75,26150,24190,15860,17870,2,1,20,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6L14-Super Low Sound Fan,2,101.5,167.75,26180,24220,15890,17900,2,1,25,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6M14-Super Low Sound Fan,2,101.5,167.75,26230,24270,15940,17950,2,1,30,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7K14-Super Low Sound Fan,2,101.5,167.75,29050,27090,18110,20120,2,1,20,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7L14-Super Low Sound Fan,2,101.5,167.75,29080,27120,18140,20150,2,1,25,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7M14-Super Low Sound Fan,2,101.5,167.75,29130,27170,18190,20200,2,1,30,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,3,4.25,"3"" [80] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M14-Super Low Sound Fan,0,36,1240,2020,124.75,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 10-3I12,2,117.75,143.75,19890,16320,9840,12390,2,1,10,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3I12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3J12,2,117.75,143.75,20020,16450,9970,12520,2,1,15,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3J12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3K12,2,117.75,143.75,20080,16510,10030,12580,2,1,20,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3L12,2,117.75,143.75,20110,16540,10060,12610,2,1,25,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3M12,2,117.75,143.75,20160,16590,10110,12660,2,1,30,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4I12,2,117.75,143.75,22430,18860,11720,14270,2,1,10,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4J12,2,117.75,143.75,22560,18990,11850,14400,2,1,15,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4K12,2,117.75,143.75,22620,19050,11910,14460,2,1,20,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4L12,2,117.75,143.75,22650,19080,11940,14490,2,1,25,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4M12,2,117.75,143.75,22700,19130,11990,14540,2,1,30,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5I12,2,117.75,143.75,24870,21300,13500,16050,2,1,10,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5J12,2,117.75,143.75,25000,21430,13630,16180,2,1,15,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5K12,2,117.75,143.75,25060,21490,13690,16240,2,1,20,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5L12,2,117.75,143.75,25090,21520,13720,16270,2,1,25,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5M12,2,117.75,143.75,25140,21570,13770,16320,2,1,30,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6I12,2,117.75,143.75,27450,23880,15420,17970,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6J12,2,117.75,143.75,27580,24010,15550,18100,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6K12,2,117.75,143.75,27640,24070,15610,18160,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6L12,2,117.75,143.75,27670,24100,15640,18190,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6M12,2,117.75,143.75,27720,24150,15690,18240,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7I12,2,117.75,143.75,30350,26780,17660,20210,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7J12,2,117.75,143.75,30480,26910,17790,20340,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7K12,2,117.75,143.75,30540,26970,17850,20400,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7L12,2,117.75,143.75,30570,27000,17880,20430,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7M12,2,117.75,143.75,30620,27050,17930,20480,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M12,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3I12-Low Sound Fan,2,117.75,143.75,19890,16320,9840,12390,2,1,10,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3I12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3J12-Low Sound Fan,2,117.75,143.75,20020,16450,9970,12520,2,1,15,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3J12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3K12-Low Sound Fan,2,117.75,143.75,20080,16510,10030,12580,2,1,20,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3L12-Low Sound Fan,2,117.75,143.75,20110,16540,10060,12610,2,1,25,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3M12-Low Sound Fan,2,117.75,143.75,20160,16590,10110,12660,2,1,30,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4I12-Low Sound Fan,2,117.75,143.75,22430,18860,11720,14270,2,1,10,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4J12-Low Sound Fan,2,117.75,143.75,22560,18990,11850,14400,2,1,15,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4K12-Low Sound Fan,2,117.75,143.75,22620,19050,11910,14460,2,1,20,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4L12-Low Sound Fan,2,117.75,143.75,22650,19080,11940,14490,2,1,25,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4M12-Low Sound Fan,2,117.75,143.75,22700,19130,11990,14540,2,1,30,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5I12-Low Sound Fan,2,117.75,143.75,24870,21300,13500,16050,2,1,10,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5J12-Low Sound Fan,2,117.75,143.75,25000,21430,13630,16180,2,1,15,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5K12-Low Sound Fan,2,117.75,143.75,25060,21490,13690,16240,2,1,20,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5L12-Low Sound Fan,2,117.75,143.75,25090,21520,13720,16270,2,1,25,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5M12-Low Sound Fan,2,117.75,143.75,25140,21570,13770,16320,2,1,30,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6I12-Low Sound Fan,2,117.75,143.75,27450,23880,15420,17970,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6J12-Low Sound Fan,2,117.75,143.75,27580,24010,15550,18100,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6K12-Low Sound Fan,2,117.75,143.75,27640,24070,15610,18160,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6L12-Low Sound Fan,2,117.75,143.75,27670,24100,15640,18190,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6M12-Low Sound Fan,2,117.75,143.75,27720,24150,15690,18240,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7I12-Low Sound Fan,2,117.75,143.75,30350,26780,17660,20210,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7J12-Low Sound Fan,2,117.75,143.75,30480,26910,17790,20340,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7K12-Low Sound Fan,2,117.75,143.75,30540,26970,17850,20400,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7L12-Low Sound Fan,2,117.75,143.75,30570,27000,17880,20430,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7M12-Low Sound Fan,2,117.75,143.75,30620,27050,17930,20480,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M12-Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3I12-Super Low Sound Fan,2,117.75,143.75,20920,17350,10870,13420,2,1,10,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3I12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3J12-Super Low Sound Fan,2,117.75,143.75,21050,17480,11000,13550,2,1,15,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3J12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3K12-Super Low Sound Fan,2,117.75,143.75,21110,17540,11060,13610,2,1,20,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3L12-Super Low Sound Fan,2,117.75,143.75,21140,17570,11090,13640,2,1,25,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3M12-Super Low Sound Fan,2,117.75,143.75,21190,17620,11140,13690,2,1,30,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4I12-Super Low Sound Fan,2,117.75,143.75,23460,19890,12750,15300,2,1,10,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4J12-Super Low Sound Fan,2,117.75,143.75,23590,20020,12880,15430,2,1,15,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4K12-Super Low Sound Fan,2,117.75,143.75,23650,20080,12940,15490,2,1,20,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4L12-Super Low Sound Fan,2,117.75,143.75,23680,20110,12970,15520,2,1,25,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4M12-Super Low Sound Fan,2,117.75,143.75,23730,20160,13020,15570,2,1,30,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5I12-Super Low Sound Fan,2,117.75,143.75,25900,22330,14530,17080,2,1,10,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5J12-Super Low Sound Fan,2,117.75,143.75,26030,22460,14660,17210,2,1,15,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5K12-Super Low Sound Fan,2,117.75,143.75,26090,22520,14720,17270,2,1,20,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5L12-Super Low Sound Fan,2,117.75,143.75,26120,22550,14750,17300,2,1,25,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5M12-Super Low Sound Fan,2,117.75,143.75,26170,22600,14800,17350,2,1,30,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6I12-Super Low Sound Fan,2,117.75,143.75,28480,24910,16450,19000,2,1,10,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6J12-Super Low Sound Fan,2,117.75,143.75,28610,25040,16580,19130,2,1,15,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6K12-Super Low Sound Fan,2,117.75,143.75,28670,25100,16640,19190,2,1,20,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6L12-Super Low Sound Fan,2,117.75,143.75,28700,25130,16670,19220,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6M12-Super Low Sound Fan,2,117.75,143.75,28750,25180,16720,19270,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7I12-Super Low Sound Fan,2,117.75,143.75,31380,27810,18690,21240,2,1,10,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7J12-Super Low Sound Fan,2,117.75,143.75,31510,27940,18820,21370,2,1,15,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7K12-Super Low Sound Fan,2,117.75,143.75,31570,28000,18880,21430,2,1,20,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7L12-Super Low Sound Fan,2,117.75,143.75,31600,28030,18910,21460,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7M12-Super Low Sound Fan,2,117.75,143.75,31650,28080,18960,21510,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M12-Super Low Sound Fan,0,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3I18,2,117.75,216,28910,23660,13990,17640,2,1,10,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3I18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3J18,2,117.75,216,29040,23790,14120,17770,2,1,15,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3J18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3K18,2,117.75,216,29100,23850,14180,17830,2,1,20,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3L18,2,117.75,216,29130,23880,14210,17860,2,1,25,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3M18,2,117.75,216,29180,23930,14260,17910,2,1,30,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3N18,2,117.75,216,29340,24090,14420,18070,2,1,40,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3N18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4I18,2,117.75,216,32700,27450,16780,20430,2,1,10,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4J18,2,117.75,216,32830,27580,16910,20560,2,1,15,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4K18,2,117.75,216,32890,27640,16970,20620,2,1,20,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4L18,2,117.75,216,32920,27670,17000,20650,2,1,25,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4M18,2,117.75,216,32970,27720,17050,20700,2,1,30,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4N18,2,117.75,216,33130,27880,17210,20860,2,1,40,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4N18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5I18,2,117.75,216,36390,31140,19480,23130,2,1,10,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5J18,2,117.75,216,36520,31270,19610,23260,2,1,15,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5K18,2,117.75,216,36580,31330,19670,23320,2,1,20,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5L18,2,117.75,216,36610,31360,19700,23350,2,1,25,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5M18,2,117.75,216,36660,31410,19750,23400,2,1,30,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5N18,2,117.75,216,36820,31570,19910,23560,2,1,40,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5N18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6I18,2,117.75,216,40260,35010,22350,26000,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6J18,2,117.75,216,40390,35140,22480,26130,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6K18,2,117.75,216,40450,35200,22540,26190,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6L18,2,117.75,216,40480,35230,22570,26220,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6M18,2,117.75,216,40530,35280,22620,26270,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6N18,2,117.75,216,40690,35440,22780,26430,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6N18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7I18,2,117.75,216,44610,39360,25710,29360,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7J18,2,117.75,216,44740,39490,25840,29490,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7K18,2,117.75,216,44800,39550,25900,29550,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7L18,2,117.75,216,44830,39580,25930,29580,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7M18,2,117.75,216,44880,39630,25980,29630,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7N18,2,117.75,216,45040,39790,26140,29790,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7N18,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3I18-Low Sound Fan,2,117.75,216,28910,23660,13990,17640,2,1,10,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3I18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3J18-Low Sound Fan,2,117.75,216,29040,23790,14120,17770,2,1,15,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3J18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3K18-Low Sound Fan,2,117.75,216,29100,23850,14180,17830,2,1,20,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3L18-Low Sound Fan,2,117.75,216,29130,23880,14210,17860,2,1,25,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3M18-Low Sound Fan,2,117.75,216,29180,23930,14260,17910,2,1,30,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3N18-Low Sound Fan,2,117.75,216,29340,24090,14420,18070,2,1,40,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3N18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4I18-Low Sound Fan,2,117.75,216,32700,27450,16780,20430,2,1,10,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4J18-Low Sound Fan,2,117.75,216,32830,27580,16910,20560,2,1,15,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4K18-Low Sound Fan,2,117.75,216,32890,27640,16970,20620,2,1,20,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4L18-Low Sound Fan,2,117.75,216,32920,27670,17000,20650,2,1,25,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4M18-Low Sound Fan,2,117.75,216,32970,27720,17050,20700,2,1,30,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4N18-Low Sound Fan,2,117.75,216,33130,27880,17210,20860,2,1,40,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4N18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5I18-Low Sound Fan,2,117.75,216,36390,31140,19480,23130,2,1,10,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5J18-Low Sound Fan,2,117.75,216,36520,31270,19610,23260,2,1,15,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5K18-Low Sound Fan,2,117.75,216,36580,31330,19670,23320,2,1,20,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5L18-Low Sound Fan,2,117.75,216,36610,31360,19700,23350,2,1,25,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5M18-Low Sound Fan,2,117.75,216,36660,31410,19750,23400,2,1,30,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5N18-Low Sound Fan,2,117.75,216,36820,31570,19910,23560,2,1,40,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5N18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6I18-Low Sound Fan,2,117.75,216,40260,35010,22350,26000,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6J18-Low Sound Fan,2,117.75,216,40390,35140,22480,26130,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6K18-Low Sound Fan,2,117.75,216,40450,35200,22540,26190,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6L18-Low Sound Fan,2,117.75,216,40480,35230,22570,26220,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6M18-Low Sound Fan,2,117.75,216,40530,35280,22620,26270,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6N18-Low Sound Fan,2,117.75,216,40690,35440,22780,26430,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6N18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7I18-Low Sound Fan,2,117.75,216,44610,39360,25710,29360,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7J18-Low Sound Fan,2,117.75,216,44740,39490,25840,29490,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7K18-Low Sound Fan,2,117.75,216,44800,39550,25900,29550,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7L18-Low Sound Fan,2,117.75,216,44830,39580,25930,29580,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7M18-Low Sound Fan,2,117.75,216,44880,39630,25980,29630,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7N18-Low Sound Fan,2,117.75,216,45040,39790,26140,29790,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7N18-Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3I18-Super Low Sound Fan,2,117.75,216,30070,24820,15150,18800,2,1,10,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3I18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3J18-Super Low Sound Fan,2,117.75,216,30200,24950,15280,18930,2,1,15,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3J18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3K18-Super Low Sound Fan,2,117.75,216,30260,25010,15340,18990,2,1,20,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3L18-Super Low Sound Fan,2,117.75,216,30290,25040,15370,19020,2,1,25,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3M18-Super Low Sound Fan,2,117.75,216,30340,25090,15420,19070,2,1,30,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3N18-Super Low Sound Fan,2,117.75,216,30500,25250,15580,19230,2,1,40,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3N18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4I18-Super Low Sound Fan,2,117.75,216,33860,28610,17940,21590,2,1,10,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4J18-Super Low Sound Fan,2,117.75,216,33990,28740,18070,21720,2,1,15,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4K18-Super Low Sound Fan,2,117.75,216,34050,28800,18130,21780,2,1,20,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4L18-Super Low Sound Fan,2,117.75,216,34080,28830,18160,21810,2,1,25,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4M18-Super Low Sound Fan,2,117.75,216,34130,28880,18210,21860,2,1,30,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4N18-Super Low Sound Fan,2,117.75,216,34290,29040,18370,22020,2,1,40,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4N18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5I18-Super Low Sound Fan,2,117.75,216,37550,32300,20640,24290,2,1,10,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5J18-Super Low Sound Fan,2,117.75,216,37680,32430,20770,24420,2,1,15,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5K18-Super Low Sound Fan,2,117.75,216,37740,32490,20830,24480,2,1,20,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5L18-Super Low Sound Fan,2,117.75,216,37770,32520,20860,24510,2,1,25,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5M18-Super Low Sound Fan,2,117.75,216,37820,32570,20910,24560,2,1,30,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5N18-Super Low Sound Fan,2,117.75,216,37980,32730,21070,24720,2,1,40,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5N18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6I18-Super Low Sound Fan,2,117.75,216,41420,36170,23510,27160,2,1,10,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6J18-Super Low Sound Fan,2,117.75,216,41550,36300,23640,27290,2,1,15,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6K18-Super Low Sound Fan,2,117.75,216,41610,36360,23700,27350,2,1,20,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6L18-Super Low Sound Fan,2,117.75,216,41640,36390,23730,27380,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6M18-Super Low Sound Fan,2,117.75,216,41690,36440,23780,27430,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6N18-Super Low Sound Fan,2,117.75,216,41850,36600,23940,27590,2,1,40,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6N18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7I18-Super Low Sound Fan,2,117.75,216,45770,40520,26870,30520,2,1,10,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7J18-Super Low Sound Fan,2,117.75,216,45900,40650,27000,30650,2,1,15,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7K18-Super Low Sound Fan,2,117.75,216,45960,40710,27060,30710,2,1,20,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7L18-Super Low Sound Fan,2,117.75,216,45990,40740,27090,30740,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7M18-Super Low Sound Fan,2,117.75,216,46040,40790,27140,30790,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7N18-Super Low Sound Fan,2,117.75,216,46200,40950,27300,30950,2,1,40,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7N18-Super Low Sound Fan,0,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 12-3J12,2,142,143.75,22870,18920,11540,14250,2,1,15,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3J12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3K12,2,142,143.75,22930,18980,11600,14310,2,1,20,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3L12,2,142,143.75,22960,19010,11630,14340,2,1,25,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3M12,2,142,143.75,23010,19060,11680,14390,2,1,30,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4J12,2,142,143.75,26000,22050,13850,16560,2,1,15,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4J12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4K12,2,142,143.75,26060,22110,13910,16620,2,1,20,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4L12,2,142,143.75,26090,22140,13940,16650,2,1,25,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4M12,2,142,143.75,26140,22190,13990,16700,2,1,30,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4N12,2,142,143.75,26300,22350,14150,16860,2,1,40,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5K12,2,142,143.75,29050,25100,16090,18800,2,1,20,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5K12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5L12,2,142,143.75,29080,25130,16120,18830,2,1,25,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5M12,2,142,143.75,29130,25180,16170,18880,2,1,30,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5N12,2,142,143.75,29290,25340,16330,19040,2,1,40,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6L12,2,142,143.75,32250,28300,18480,21190,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6M12,2,142,143.75,32300,28350,18530,21240,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6N12,2,142,143.75,32460,28510,18690,21400,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7L12,2,142,143.75,35680,31730,21100,23810,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7M12,2,142,143.75,35730,31780,21150,23860,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7N12,2,142,143.75,35890,31940,21310,24020,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N12,0,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3J12-Low Sound Fan,2,142,143.75,22870,18920,11540,14250,2,1,15,161.90625,43.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3J12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3K12-Low Sound Fan,2,142,143.75,22930,18980,11600,14310,2,1,20,161.90625,43.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3L12-Low Sound Fan,2,142,143.75,22960,19010,11630,14340,2,1,25,161.90625,43.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3M12-Low Sound Fan,2,142,143.75,23010,19060,11680,14390,2,1,30,161.90625,43.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4J12-Low Sound Fan,2,142,143.75,26000,22050,13850,16560,2,1,15,170.65625,51.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4J12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4K12-Low Sound Fan,2,142,143.75,26060,22110,13910,16620,2,1,20,170.65625,51.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4L12-Low Sound Fan,2,142,143.75,26090,22140,13940,16650,2,1,25,170.65625,51.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4M12-Low Sound Fan,2,142,143.75,26140,22190,13990,16700,2,1,30,170.65625,51.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4N12-Low Sound Fan,2,142,143.75,26300,22350,14150,16860,2,1,40,170.65625,51.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5K12-Low Sound Fan,2,142,143.75,29050,25100,16090,18800,2,1,20,178.90625,60.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5K12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5L12-Low Sound Fan,2,142,143.75,29080,25130,16120,18830,2,1,25,178.90625,60.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5M12-Low Sound Fan,2,142,143.75,29130,25180,16170,18880,2,1,30,178.90625,60.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5N12-Low Sound Fan,2,142,143.75,29290,25340,16330,19040,2,1,40,178.90625,60.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6L12-Low Sound Fan,2,142,143.75,32250,28300,18480,21190,2,1,25,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6M12-Low Sound Fan,2,142,143.75,32300,28350,18530,21240,2,1,30,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6N12-Low Sound Fan,2,142,143.75,32460,28510,18690,21400,2,1,40,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7L12-Low Sound Fan,2,142,143.75,35680,31730,21100,23810,2,1,25,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7M12-Low Sound Fan,2,142,143.75,35730,31780,21150,23860,2,1,30,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7N12-Low Sound Fan,2,142,143.75,35890,31940,21310,24020,2,1,40,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N12-Low Sound Fan,0,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3J12-Super Low Sound Fan,2,142,143.75,23660,19710,12330,15040,2,1,15,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3J12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3K12-Super Low Sound Fan,2,142,143.75,23720,19770,12390,15100,2,1,20,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3L12-Super Low Sound Fan,2,142,143.75,23750,19800,12420,15130,2,1,25,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3M12-Super Low Sound Fan,2,142,143.75,23800,19850,12470,15180,2,1,30,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4J12-Super Low Sound Fan,2,142,143.75,26790,22840,14640,17350,2,1,15,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4J12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4K12-Super Low Sound Fan,2,142,143.75,26850,22900,14700,17410,2,1,20,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4L12-Super Low Sound Fan,2,142,143.75,26880,22930,14730,17440,2,1,25,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4M12-Super Low Sound Fan,2,142,143.75,26930,22980,14780,17490,2,1,30,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4N12-Super Low Sound Fan,2,142,143.75,27090,23140,14940,17650,2,1,40,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5K12-Super Low Sound Fan,2,142,143.75,29840,25890,16880,19590,2,1,20,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5K12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5L12-Super Low Sound Fan,2,142,143.75,29870,25920,16910,19620,2,1,25,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5M12-Super Low Sound Fan,2,142,143.75,29920,25970,16960,19670,2,1,30,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5N12-Super Low Sound Fan,2,142,143.75,30080,26130,17120,19830,2,1,40,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6L12-Super Low Sound Fan,2,142,143.75,33040,29090,19270,21980,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6M12-Super Low Sound Fan,2,142,143.75,33090,29140,19320,22030,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6N12-Super Low Sound Fan,2,142,143.75,33250,29300,19480,22190,2,1,40,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7L12-Super Low Sound Fan,2,142,143.75,36470,32520,21890,24600,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7M12-Super Low Sound Fan,2,142,143.75,36520,32570,21940,24650,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7N12-Super Low Sound Fan,2,142,143.75,36680,32730,22100,24810,2,1,40,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N12-Super Low Sound Fan,0,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3K14,2,142,167.75,26340,21770,13160,16220,2,1,20,167.875,43.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3L14,2,142,167.75,26370,21800,13190,16250,2,1,25,167.875,43.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3M14,2,142,167.75,26420,21850,13240,16300,2,1,30,167.875,43.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3N14,2,142,167.75,26580,22010,13400,16460,2,1,40,167.875,43.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4K14,2,142,167.75,29970,25400,15840,18900,2,1,20,176.375,51.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4L14,2,142,167.75,30000,25430,15870,18930,2,1,25,176.375,51.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4M14,2,142,167.75,30050,25480,15920,18980,2,1,30,176.375,51.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4N14,2,142,167.75,30210,25640,16080,19140,2,1,40,176.375,51.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5L14,2,142,167.75,33460,28890,18380,21440,2,1,25,184.875,60.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5M14,2,142,167.75,33510,28940,18430,21490,2,1,30,184.875,60.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5N14,2,142,167.75,33670,29100,18590,21650,2,1,40,184.875,60.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6L14,2,142,167.75,37400,32830,21370,24430,2,1,25,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6M14,2,142,167.75,37450,32880,21420,24480,2,1,30,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6N14,2,142,167.75,37610,33040,21580,24640,2,1,40,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7L14,2,142,167.75,41450,36880,24470,27530,2,1,25,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7M14,2,142,167.75,41500,36930,24520,27580,2,1,30,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7N14,2,142,167.75,41660,37090,24680,27740,2,1,40,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N14,0,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3K14-Low Sound Fan,2,142,167.75,26565,21995,13385,16445,2,1,20,174.875,43.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3L14-Low Sound Fan,2,142,167.75,26595,22025,13415,16475,2,1,25,174.875,43.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3M14-Low Sound Fan,2,142,167.75,26645,22075,13465,16525,2,1,30,174.875,43.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3N14-Low Sound Fan,2,142,167.75,26805,22235,13625,16685,2,1,40,174.875,43.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4K14-Low Sound Fan,2,142,167.75,30195,25625,16065,19125,2,1,20,183.375,51.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4L14-Low Sound Fan,2,142,167.75,30225,25655,16095,19155,2,1,25,183.375,51.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4M14-Low Sound Fan,2,142,167.75,30275,25705,16145,19205,2,1,30,183.375,51.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4N14-Low Sound Fan,2,142,167.75,30435,25865,16305,19365,2,1,40,183.375,51.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5L14-Low Sound Fan,2,142,167.75,33685,29115,18605,21665,2,1,25,191.875,60.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5M14-Low Sound Fan,2,142,167.75,33735,29165,18655,21715,2,1,30,191.875,60.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5N14-Low Sound Fan,2,142,167.75,33895,29325,18815,21875,2,1,40,191.875,60.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6L14-Low Sound Fan,2,142,167.75,37625,33055,21595,24655,2,1,25,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6M14-Low Sound Fan,2,142,167.75,37675,33105,21645,24705,2,1,30,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6N14-Low Sound Fan,2,142,167.75,37835,33265,21805,24865,2,1,40,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7L14-Low Sound Fan,2,142,167.75,41675,37105,24695,27755,2,1,25,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7M14-Low Sound Fan,2,142,167.75,41725,37155,24745,27805,2,1,30,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7N14-Low Sound Fan,2,142,167.75,41885,37315,24905,27965,2,1,40,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N14-Low Sound Fan,0,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3K14-Super Low Sound Fan,2,142,167.75,27480,22910,14300,17360,2,1,20,189.375,43.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3L14-Super Low Sound Fan,2,142,167.75,27510,22940,14330,17390,2,1,25,189.375,43.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3M14-Super Low Sound Fan,2,142,167.75,27560,22990,14380,17440,2,1,30,189.375,43.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3N14-Super Low Sound Fan,2,142,167.75,27720,23150,14540,17600,2,1,40,189.375,43.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4K14-Super Low Sound Fan,2,142,167.75,31110,26540,16980,20040,2,1,20,197.875,51.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4L14-Super Low Sound Fan,2,142,167.75,31140,26570,17010,20070,2,1,25,197.875,51.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4M14-Super Low Sound Fan,2,142,167.75,31190,26620,17060,20120,2,1,30,197.875,51.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4N14-Super Low Sound Fan,2,142,167.75,31350,26780,17220,20280,2,1,40,197.875,51.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5L14-Super Low Sound Fan,2,142,167.75,34600,30030,19520,22580,2,1,25,206.375,60.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5M14-Super Low Sound Fan,2,142,167.75,34650,30080,19570,22630,2,1,30,206.375,60.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5N14-Super Low Sound Fan,2,142,167.75,34810,30240,19730,22790,2,1,40,206.375,60.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6L14-Super Low Sound Fan,2,142,167.75,38540,33970,22510,25570,2,1,25,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6M14-Super Low Sound Fan,2,142,167.75,38590,34020,22560,25620,2,1,30,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6N14-Super Low Sound Fan,2,142,167.75,38750,34180,22720,25780,2,1,40,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7L14-Super Low Sound Fan,2,142,167.75,42590,38020,25610,28670,2,1,25,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7M14-Super Low Sound Fan,2,142,167.75,42640,38070,25660,28720,2,1,30,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7N14-Super Low Sound Fan,2,142,167.75,42800,38230,25820,28880,2,1,40,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N14-Super Low Sound Fan,0,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3K18,2,142,216,33210,27340,16350,20270,2,1,20,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3L18,2,142,216,33240,27370,16380,20300,2,1,25,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3M18,2,142,216,33290,27420,16430,20350,2,1,30,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3N18,2,142,216,33450,27580,16590,20510,2,1,40,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4K18,2,142,216,37870,32000,19780,23700,2,1,20,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4L18,2,142,216,37900,32030,19810,23730,2,1,25,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4M18,2,142,216,37950,32080,19860,23780,2,1,30,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4N18,2,142,216,38110,32240,20020,23940,2,1,40,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4O18,2,142,216,38120,32250,20030,23950,2,1,50,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5L18,2,142,216,42410,36540,23100,27020,2,1,25,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5M18,2,142,216,42460,36590,23150,27070,2,1,30,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5N18,2,142,216,42620,36750,23310,27230,2,1,40,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5O18,2,142,216,42630,36760,23320,27240,2,1,50,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6M18,2,142,216,47090,41220,26550,30470,2,1,30,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6N18,2,142,216,47250,41380,26710,30630,2,1,40,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6O18,2,142,216,47260,41390,26720,30640,2,1,50,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6P18,2,142,216,47460,41590,26920,30840,2,1,60,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7M18,2,142,216,52240,46370,30470,34390,2,1,30,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7N18,2,142,216,52400,46530,30630,34550,2,1,40,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7O18,2,142,216,52410,46540,30640,34560,2,1,50,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7P18,2,142,216,52610,46740,30840,34760,2,1,60,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P18,0,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3K18-Low Sound Fan,2,142,216,33435,27565,16575,20495,2,1,20,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3L18-Low Sound Fan,2,142,216,33465,27595,16605,20525,2,1,25,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3M18-Low Sound Fan,2,142,216,33515,27645,16655,20575,2,1,30,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3N18-Low Sound Fan,2,142,216,33675,27805,16815,20735,2,1,40,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4K18-Low Sound Fan,2,142,216,38095,32225,20005,23925,2,1,20,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4L18-Low Sound Fan,2,142,216,38125,32255,20035,23955,2,1,25,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4M18-Low Sound Fan,2,142,216,38175,32305,20085,24005,2,1,30,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4N18-Low Sound Fan,2,142,216,38335,32465,20245,24165,2,1,40,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4O18-Low Sound Fan,2,142,216,38345,32475,20255,24175,2,1,50,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5L18-Low Sound Fan,2,142,216,42635,36765,23325,27245,2,1,25,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5M18-Low Sound Fan,2,142,216,42685,36815,23375,27295,2,1,30,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5N18-Low Sound Fan,2,142,216,42845,36975,23535,27455,2,1,40,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5O18-Low Sound Fan,2,142,216,42855,36985,23545,27465,2,1,50,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6M18-Low Sound Fan,2,142,216,47315,41445,26775,30695,2,1,30,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6N18-Low Sound Fan,2,142,216,47475,41605,26935,30855,2,1,40,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6O18-Low Sound Fan,2,142,216,47485,41615,26945,30865,2,1,50,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6P18-Low Sound Fan,2,142,216,47685,41815,27145,31065,2,1,60,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7M18-Low Sound Fan,2,142,216,52465,46595,30695,34615,2,1,30,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7N18-Low Sound Fan,2,142,216,52625,46755,30855,34775,2,1,40,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7O18-Low Sound Fan,2,142,216,52635,46765,30865,34785,2,1,50,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7P18-Low Sound Fan,2,142,216,52835,46965,31065,34985,2,1,60,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P18-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3K18-Super Low Sound Fan,2,142,216,34450,28580,17590,21510,2,1,20,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3L18-Super Low Sound Fan,2,142,216,34480,28610,17620,21540,2,1,25,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3M18-Super Low Sound Fan,2,142,216,34530,28660,17670,21590,2,1,30,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3N18-Super Low Sound Fan,2,142,216,34690,28820,17830,21750,2,1,40,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4K18-Super Low Sound Fan,2,142,216,39110,33240,21020,24940,2,1,20,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4L18-Super Low Sound Fan,2,142,216,39140,33270,21050,24970,2,1,25,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4M18-Super Low Sound Fan,2,142,216,39190,33320,21100,25020,2,1,30,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4N18-Super Low Sound Fan,2,142,216,39350,33480,21260,25180,2,1,40,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4O18-Super Low Sound Fan,2,142,216,39360,33490,21270,25190,2,1,50,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5L18-Super Low Sound Fan,2,142,216,43650,37780,24340,28260,2,1,25,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5M18-Super Low Sound Fan,2,142,216,43700,37830,24390,28310,2,1,30,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5N18-Super Low Sound Fan,2,142,216,43860,37990,24550,28470,2,1,40,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5O18-Super Low Sound Fan,2,142,216,43870,38000,24560,28480,2,1,50,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6M18-Super Low Sound Fan,2,142,216,48330,42460,27790,31710,2,1,30,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6N18-Super Low Sound Fan,2,142,216,48490,42620,27950,31870,2,1,40,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6O18-Super Low Sound Fan,2,142,216,48500,42630,27960,31880,2,1,50,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6P18-Super Low Sound Fan,2,142,216,48700,42830,28160,32080,2,1,60,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7M18-Super Low Sound Fan,2,142,216,53480,47610,31710,35630,2,1,30,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7N18-Super Low Sound Fan,2,142,216,53640,47770,31870,35790,2,1,40,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7O18-Super Low Sound Fan,2,142,216,53650,47780,31880,35800,2,1,50,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7P18-Super Low Sound Fan,2,142,216,53850,47980,32080,36000,2,1,60,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P18-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3L20,2,142,240,36840,30140,17860,22370,2,1,25,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3M20,2,142,240,36890,30190,17910,22420,2,1,30,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3N20,2,142,240,37050,30350,18070,22580,2,1,40,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3O20,2,142,240,37060,30360,18080,22590,2,1,50,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3O20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4L20,2,142,240,41990,35290,21640,26150,2,1,25,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4M20,2,142,240,42040,35340,21690,26200,2,1,30,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4N20,2,142,240,42200,35500,21850,26360,2,1,40,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4O20,2,142,240,42210,35510,21860,26370,2,1,50,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5M20,2,142,240,47090,40390,25370,29880,2,1,30,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5N20,2,142,240,47250,40550,25530,30040,2,1,40,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5O20,2,142,240,47260,40560,25540,30050,2,1,50,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5P20,2,142,240,47460,40760,25740,30250,2,1,60,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5P20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6N20,2,142,240,52750,46050,29670,34180,2,1,40,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6O20,2,142,240,52760,46060,29680,34190,2,1,50,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6P20,2,142,240,52960,46260,29880,34390,2,1,60,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7N20,2,142,240,58560,51860,34110,38620,2,1,40,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7O20,2,142,240,58570,51870,34120,38630,2,1,50,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7P20,2,142,240,58770,52070,34320,38830,2,1,60,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P20,0,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3L20-Low Sound Fan,2,142,240,37065,30365,18085,22595,2,1,25,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3M20-Low Sound Fan,2,142,240,37115,30415,18135,22645,2,1,30,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3N20-Low Sound Fan,2,142,240,37275,30575,18295,22805,2,1,40,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3O20-Low Sound Fan,2,142,240,37285,30585,18305,22815,2,1,50,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3O20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4L20-Low Sound Fan,2,142,240,42215,35515,21865,26375,2,1,25,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4M20-Low Sound Fan,2,142,240,42265,35565,21915,26425,2,1,30,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4N20-Low Sound Fan,2,142,240,42425,35725,22075,26585,2,1,40,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4O20-Low Sound Fan,2,142,240,42435,35735,22085,26595,2,1,50,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5M20-Low Sound Fan,2,142,240,47315,40615,25595,30105,2,1,30,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5N20-Low Sound Fan,2,142,240,47475,40775,25755,30265,2,1,40,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5O20-Low Sound Fan,2,142,240,47485,40785,25765,30275,2,1,50,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5P20-Low Sound Fan,2,142,240,47685,40985,25965,30475,2,1,60,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5P20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6N20-Low Sound Fan,2,142,240,52975,46275,29895,34405,2,1,40,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6O20-Low Sound Fan,2,142,240,52985,46285,29905,34415,2,1,50,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6P20-Low Sound Fan,2,142,240,53185,46485,30105,34615,2,1,60,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7N20-Low Sound Fan,2,142,240,58785,52085,34335,38845,2,1,40,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7O20-Low Sound Fan,2,142,240,58795,52095,34345,38855,2,1,50,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7P20-Low Sound Fan,2,142,240,58995,52295,34545,39055,2,1,60,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P20-Low Sound Fan,0,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3L20-Super Low Sound Fan,2,142,240,38080,31380,19100,23610,2,1,25,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3M20-Super Low Sound Fan,2,142,240,38130,31430,19150,23660,2,1,30,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3N20-Super Low Sound Fan,2,142,240,38290,31590,19310,23820,2,1,40,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3O20-Super Low Sound Fan,2,142,240,38300,31600,19320,23830,2,1,50,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3O20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4L20-Super Low Sound Fan,2,142,240,43230,36530,22880,27390,2,1,25,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4M20-Super Low Sound Fan,2,142,240,43280,36580,22930,27440,2,1,30,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4N20-Super Low Sound Fan,2,142,240,43440,36740,23090,27600,2,1,40,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4O20-Super Low Sound Fan,2,142,240,43450,36750,23100,27610,2,1,50,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5M20-Super Low Sound Fan,2,142,240,48330,41630,26610,31120,2,1,30,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5N20-Super Low Sound Fan,2,142,240,48490,41790,26770,31280,2,1,40,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5O20-Super Low Sound Fan,2,142,240,48500,41800,26780,31290,2,1,50,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5P20-Super Low Sound Fan,2,142,240,48700,42000,26980,31490,2,1,60,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5P20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6N20-Super Low Sound Fan,2,142,240,53990,47290,30910,35420,2,1,40,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6O20-Super Low Sound Fan,2,142,240,54000,47300,30920,35430,2,1,50,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6P20-Super Low Sound Fan,2,142,240,54200,47500,31120,35630,2,1,60,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7N20-Super Low Sound Fan,2,142,240,59800,53100,35350,39860,2,1,40,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7O20-Super Low Sound Fan,2,142,240,59810,53110,35360,39870,2,1,50,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7P20-Super Low Sound Fan,2,142,240,60010,53310,35560,40070,2,1,60,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P20-Super Low Sound Fan,0,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 7-3H9-Z,2,88,107.5,10080,8910,5960,7550,2,1,7.5,136.125,48.875,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3H9-Z,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3I9-Z,2,88,107.5,10100,8930,5980,7570,2,1,10,136.125,48.875,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3I9-Z,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4I9-Z,2,88,107.5,11490,10320,7010,8600,2,1,10,143.625,56.375,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4I9-Z,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4J9-Z,2,88,107.5,11610,10440,7130,8720,2,1,15,143.625,56.375,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J9-Z,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5I9-Z,2,88,107.5,12960,11790,8110,9700,2,1,10,151.125,63.875,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5I9-Z,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5J9-Z,2,88,107.5,13080,11910,8230,9820,2,1,15,151.125,63.875,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J9-Z,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-6J9-Z,2,88,107.5,14500,13330,9290,10880,2,1,15,158.625,71.375,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6J9-Z,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,98,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-7J9-Z,2,88,107.5,16000,14830,10420,12010,2,1,15,164.375,77.125,14,84,17,6.5,28.375,4,"4"" [100] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7J9-Z,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,103.75,39.5,2.625,570,32.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3H9-Z-Low Sound Fan,2,88,107.5,10080,8910,5960,7550,2,1,7.5,140.125,48.875,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3H9-Z-Low Sound Fan,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3I9-Z-Low Sound Fan,2,88,107.5,10100,8930,5980,7570,2,1,10,140.125,48.875,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3I9-Z-Low Sound Fan,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4I9-Z-Low Sound Fan,2,88,107.5,11490,10320,7010,8600,2,1,10,147.625,56.375,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4I9-Z-Low Sound Fan,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4J9-Z-Low Sound Fan,2,88,107.5,11610,10440,7130,8720,2,1,15,147.625,56.375,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J9-Z-Low Sound Fan,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5I9-Z-Low Sound Fan,2,88,107.5,12960,11790,8110,9700,2,1,10,155.125,63.875,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5I9-Z-Low Sound Fan,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5J9-Z-Low Sound Fan,2,88,107.5,13080,11910,8230,9820,2,1,15,155.125,63.875,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J9-Z-Low Sound Fan,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-6J9-Z-Low Sound Fan,2,88,107.5,14500,13330,9290,10880,2,1,15,162.625,71.375,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6J9-Z-Low Sound Fan,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,98,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-7J9-Z-Low Sound Fan,2,88,107.5,16000,14830,10420,12010,2,1,15,168.375,77.125,18,84,17,6.5,28.375,4,"4"" [100] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7J9-Z-Low Sound Fan,1,36,910,1640,104,55.625,75,7.25,41.875,88.875,103.75,39.5,2.625,570,32.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3H9-Z-Super Low Sound Fan,2,88,107.5,10560,9390,6440,8030,2,1,7.5,154.125,48.875,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3H9-Z-Super Low Sound Fan,1,36,975,1640,104,55.625,75,7.25,55.75,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3I9-Z-Super Low Sound Fan,2,88,107.5,10580,9410,6460,8050,2,1,10,154.125,48.875,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3I9-Z-Super Low Sound Fan,1,36,975,1640,104,55.625,75,7.25,55.75,88.875,75.5,39.5,2.625,570,22.875,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4I9-Z-Super Low Sound Fan,2,88,107.5,11970,10800,7490,9080,2,1,10,161.625,56.375,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4I9-Z-Super Low Sound Fan,1,36,975,1640,104,55.625,75,7.25,55.75,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-4J9-Z-Super Low Sound Fan,2,88,107.5,12090,10920,7610,9200,2,1,15,161.625,56.375,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J9-Z-Super Low Sound Fan,1,36,975,1640,104,55.625,75,7.25,55.75,88.875,83,39.5,2.625,570,26,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5I9-Z-Super Low Sound Fan,2,88,107.5,13440,12270,8590,10180,2,1,10,169.125,63.875,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5I9-Z-Super Low Sound Fan,1,36,975,1640,104,55.625,75,7.25,55.75,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-5J9-Z-Super Low Sound Fan,2,88,107.5,13560,12390,8710,10300,2,1,15,169.125,63.875,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J9-Z-Super Low Sound Fan,1,36,975,1640,104,55.625,75,7.25,55.75,88.875,90.5,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-6J9-Z-Super Low Sound Fan,2,88,107.5,14980,13810,9770,11360,2,1,15,176.625,71.375,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6J9-Z-Super Low Sound Fan,1,36,975,1640,104,55.625,75,7.25,55.75,88.875,98,39.5,2.625,570,29,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-7J9-Z-Super Low Sound Fan,2,88,107.5,16480,15310,10900,12490,2,1,15,182.375,77.125,32,84,17,6.5,28.375,4,"4"" [100] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7J9-Z-Super Low Sound Fan,1,36,975,1640,104,55.625,75,7.25,55.75,88.875,103.75,39.5,2.625,570,32.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,15.75,1,12,20.68,9.72
ATWB 7-3J12-Z,2,88,143.75,12760,11150,7370,9270,2,1,15,136.125,48.875,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J12-Z,1,36,1055,1640,104,55.625,83,21,41.875,88.875,75.5,39.5,15.625,570,40.625,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-4J12-Z,2,88,143.75,14650,13040,8770,10670,2,1,15,143.625,56.375,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J12-Z,1,36,1055,1640,104,55.625,83,21,41.875,88.875,83,39.5,15.625,570,43.75,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5J12-Z,2,88,143.75,16520,14910,10150,12050,2,1,15,151.125,63.875,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J12-Z,1,36,1055,1640,104,55.625,83,21,41.875,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5K12-Z,2,88,143.75,16580,14970,10210,12110,2,1,20,151.125,63.875,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K12-Z,1,36,1055,1640,104,55.625,83,21,41.875,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-6K12-Z,2,88,143.75,18490,16880,11630,13530,2,1,20,158.625,71.375,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K12-Z,1,36,1055,1640,104,55.625,83,21,41.875,88.875,98,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-7K12-Z,2,88,143.75,20400,18790,13050,14950,2,1,20,164.375,77.125,14,84,17,6.5,28.375,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7K12-Z,1,36,1055,1640,104,55.625,83,21,41.875,88.875,103.75,39.5,15.625,570,49.875,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-3J12-Z-Low Sound Fan,2,88,143.75,12760,11150,7370,9270,2,1,15,140.125,48.875,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J12-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,21,41.875,88.875,75.5,39.5,15.625,570,40.625,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-4J12-Z-Low Sound Fan,2,88,143.75,14650,13040,8770,10670,2,1,15,147.625,56.375,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J12-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,21,41.875,88.875,83,39.5,15.625,570,43.75,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5J12-Z-Low Sound Fan,2,88,143.75,16520,14910,10150,12050,2,1,15,155.125,63.875,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J12-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,21,41.875,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5K12-Z-Low Sound Fan,2,88,143.75,16580,14970,10210,12110,2,1,20,155.125,63.875,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K12-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,21,41.875,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-6K12-Z-Low Sound Fan,2,88,143.75,18490,16880,11630,13530,2,1,20,162.625,71.375,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K12-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,21,41.875,88.875,98,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-7K12-Z-Low Sound Fan,2,88,143.75,20400,18790,13050,14950,2,1,20,168.375,77.125,18,84,17,6.5,28.375,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7K12-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,21,41.875,88.875,103.75,39.5,15.625,570,49.875,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-3J12-Z-Super Low Sound Fan,2,88,143.75,13300,11690,7910,9810,2,1,15,154.125,48.875,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J12-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,21,55.75,88.875,75.5,39.5,15.625,570,40.625,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-4J12-Z-Super Low Sound Fan,2,88,143.75,15190,13580,9310,11210,2,1,15,161.625,56.375,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J12-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,21,55.75,88.875,83,39.5,15.625,570,43.75,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5J12-Z-Super Low Sound Fan,2,88,143.75,17060,15450,10690,12590,2,1,15,169.125,63.875,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J12-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,21,55.75,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-5K12-Z-Super Low Sound Fan,2,88,143.75,17120,15510,10750,12650,2,1,20,169.125,63.875,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K12-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,21,55.75,88.875,90.5,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-6K12-Z-Super Low Sound Fan,2,88,143.75,19030,17420,12170,14070,2,1,20,176.625,71.375,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K12-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,21,55.75,88.875,98,39.5,15.625,570,46.75,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-7K12-Z-Super Low Sound Fan,2,88,143.75,20940,19330,13590,15490,2,1,20,182.375,77.125,32,84,17,6.5,28.375,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7K12-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,21,55.75,88.875,103.75,39.5,15.625,570,49.875,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,12,21.52,9.72
ATWB 7-3J14-Z,2,88,167.75,14570,12760,8380,10570,2,1,15,140.5,48.875,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J14-Z,1,36,1055,1640,104,55.625,83,33,41.875,88.875,79.875,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-4J14-Z,2,88,167.75,16760,14950,9990,12180,2,1,15,148,56.375,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J14-Z,1,36,1055,1640,104,55.625,83,33,41.875,88.875,87.375,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5J14-Z,2,88,167.75,18990,17180,11650,13840,2,1,15,155.5,63.875,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J14-Z,1,36,1055,1640,104,55.625,83,33,41.875,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5K14-Z,2,88,167.75,19050,17240,11710,13900,2,1,20,155.5,63.875,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K14-Z,1,36,1055,1640,104,55.625,83,33,41.875,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6K14-Z,2,88,167.75,21270,19460,13360,15550,2,1,20,163,71.375,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K14-Z,1,36,1055,1640,104,55.625,83,33,41.875,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6L14-Z,2,88,167.75,21300,19490,13390,15580,2,1,25,163,71.375,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6L14-Z,1,36,1055,1640,104,55.625,83,33,41.875,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-7L14-Z,2,88,167.75,21910,20100,13420,15610,2,1,25,168.75,77.125,14,84,17,6.5,32.75,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7L14-Z,1,36,1055,1640,104,55.625,83,33,41.875,88.875,108.125,39.5,27.625,570,65.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-3J14-Z-Low Sound Fan,2,88,167.75,14570,12760,8380,10570,2,1,15,144.5,48.875,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J14-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,33,41.875,88.875,79.875,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-4J14-Z-Low Sound Fan,2,88,167.75,16760,14950,9990,12180,2,1,15,152,56.375,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J14-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,33,41.875,88.875,87.375,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5J14-Z-Low Sound Fan,2,88,167.75,18990,17180,11650,13840,2,1,15,159.5,63.875,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J14-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,33,41.875,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5K14-Z-Low Sound Fan,2,88,167.75,19050,17240,11710,13900,2,1,20,159.5,63.875,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K14-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,33,41.875,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6K14-Z-Low Sound Fan,2,88,167.75,21270,19460,13360,15550,2,1,20,167,71.375,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K14-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,33,41.875,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6L14-Z-Low Sound Fan,2,88,167.75,21300,19490,13390,15580,2,1,25,167,71.375,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6L14-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,33,41.875,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-7L14-Z-Low Sound Fan,2,88,167.75,21910,20100,13420,15610,2,1,25,172.625,77.125,18,84,17,6.5,32.75,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7L14-Z-Low Sound Fan,1,36,1055,1640,104,55.625,83,33,41.875,88.875,108.125,39.5,27.625,570,65.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-3J14-Z-Super Low Sound Fan,2,88,167.75,15120,13310,8930,11120,2,1,15,158.5,48.875,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",36.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-3J14-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,33,55.75,88.875,79.875,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,19.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-4J14-Z-Super Low Sound Fan,2,88,167.75,17310,15500,10540,12730,2,1,15,166,56.375,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",44.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-4J14-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,33,55.75,88.875,87.375,39.5,27.625,570,59.25,0.5,0,22.875,42.25,12.5,20.75,27,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5J14-Z-Super Low Sound Fan,2,88,167.75,19540,17730,12200,14390,2,1,15,173.5,63.875,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5J14-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,33,55.75,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-5K14-Z-Super Low Sound Fan,2,88,167.75,19600,17790,12260,14450,2,1,20,173.5,63.875,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",51.625,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-5K14-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,33,55.75,88.875,94.875,39.5,27.625,570,61.875,0.5,0,22.875,42.25,12.5,20.75,34.5,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6K14-Z-Super Low Sound Fan,2,88,167.75,21820,20010,13910,16100,2,1,20,181,71.375,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6K14-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,33,55.75,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-6L14-Z-Super Low Sound Fan,2,88,167.75,21850,20040,13940,16130,2,1,25,181,71.375,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",59.125,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-6L14-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,33,55.75,88.875,102.375,39.5,27.625,570,64.875,0.5,0,22.875,42.25,12.5,20.75,42,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 7-7L14-Z-Super Low Sound Fan,2,88,167.75,22460,20650,13970,16160,2,1,25,186.625,77.125,32,84,17,6.5,32.75,6,"6"" [150] FPT INLET",64.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.625,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,14.5,3.625,1,17.125,ATWB 7-7L14-Z-Super Low Sound Fan,1,36,1150,1640,104,55.625,83,33,55.75,88.875,108.125,39.5,27.625,570,65.125,0.5,0,22.875,42.25,12.5,20.75,47.75,5.25,7,4,8.375,8.5,17.125,1,36,23.84,9.72
ATWB 8-3G9-Z,2,94,107.5,11340,10110,6230,7630,2,1,5,135.375,30.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3G9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3H9-Z,2,94,107.5,11390,10160,6280,7680,2,1,7.5,135.375,30.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3I9-Z,2,94,107.5,11400,10170,6290,7690,2,1,10,135.375,30.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3J9-Z,2,94,107.5,11530,10300,6420,7820,2,1,15,135.375,30.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4G9-Z,2,94,107.5,12820,11590,7320,8720,2,1,5,142.875,38.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4G9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4H9-Z,2,94,107.5,12870,11640,7370,8770,2,1,7.5,142.875,38.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4I9-Z,2,94,107.5,12880,11650,7380,8780,2,1,10,142.875,38.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4J9-Z,2,94,107.5,13010,11780,7510,8910,2,1,15,142.875,38.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4K9-Z,2,94,107.5,13070,11840,7570,8970,2,1,20,142.875,38.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5G9-Z,2,94,107.5,14370,13140,8480,9880,2,1,5,150.375,45.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5G9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5H9-Z,2,94,107.5,14420,13190,8530,9930,2,1,7.5,150.375,45.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5I9-Z,2,94,107.5,14430,13200,8540,9940,2,1,10,150.375,45.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5J9-Z,2,94,107.5,14560,13330,8670,10070,2,1,15,150.375,45.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5K9-Z,2,94,107.5,14620,13390,8730,10130,2,1,20,150.375,45.625,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6G9-Z,2,94,107.5,15910,14680,9640,11040,2,1,5,157.875,53.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6G9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6H9-Z,2,94,107.5,15960,14730,9690,11090,2,1,7.5,157.875,53.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6I9-Z,2,94,107.5,15970,14740,9700,11100,2,1,10,157.875,53.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6J9-Z,2,94,107.5,16100,14870,9830,11230,2,1,15,157.875,53.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6K9-Z,2,94,107.5,16160,14930,9890,11290,2,1,20,157.875,53.125,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7G9-Z,2,94,107.5,17540,16310,10880,12280,2,1,5,163.625,58.875,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7G9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7H9-Z,2,94,107.5,17590,16360,10930,12330,2,1,7.5,163.625,58.875,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7I9-Z,2,94,107.5,17600,16370,10940,12340,2,1,10,163.625,58.875,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7J9-Z,2,94,107.5,17730,16500,11070,12470,2,1,15,163.625,58.875,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7K9-Z,2,94,107.5,17790,16560,11130,12530,2,1,20,163.625,58.875,12.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K9-Z,1,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3G9-Z-Low Sound Fan,2,94,107.5,11340,10110,6230,7630,2,1,5,139.375,30.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3G9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3H9-Z-Low Sound Fan,2,94,107.5,11390,10160,6280,7680,2,1,7.5,139.375,30.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3I9-Z-Low Sound Fan,2,94,107.5,11400,10170,6290,7690,2,1,10,139.375,30.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3J9-Z-Low Sound Fan,2,94,107.5,11530,10300,6420,7820,2,1,15,139.375,30.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4G9-Z-Low Sound Fan,2,94,107.5,12820,11590,7320,8720,2,1,5,146.875,38.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4G9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4H9-Z-Low Sound Fan,2,94,107.5,12870,11640,7370,8770,2,1,7.5,146.875,38.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4I9-Z-Low Sound Fan,2,94,107.5,12880,11650,7380,8780,2,1,10,146.875,38.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4J9-Z-Low Sound Fan,2,94,107.5,13010,11780,7510,8910,2,1,15,146.875,38.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4K9-Z-Low Sound Fan,2,94,107.5,13070,11840,7570,8970,2,1,20,146.875,38.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5G9-Z-Low Sound Fan,2,94,107.5,14370,13140,8480,9880,2,1,5,154.375,45.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5G9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5H9-Z-Low Sound Fan,2,94,107.5,14420,13190,8530,9930,2,1,7.5,154.375,45.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5I9-Z-Low Sound Fan,2,94,107.5,14430,13200,8540,9940,2,1,10,154.375,45.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5J9-Z-Low Sound Fan,2,94,107.5,14560,13330,8670,10070,2,1,15,154.375,45.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5K9-Z-Low Sound Fan,2,94,107.5,14620,13390,8730,10130,2,1,20,154.375,45.625,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6G9-Z-Low Sound Fan,2,94,107.5,15910,14680,9640,11040,2,1,5,161.875,53.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6G9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6H9-Z-Low Sound Fan,2,94,107.5,15960,14730,9690,11090,2,1,7.5,161.875,53.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6I9-Z-Low Sound Fan,2,94,107.5,15970,14740,9700,11100,2,1,10,161.875,53.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6J9-Z-Low Sound Fan,2,94,107.5,16100,14870,9830,11230,2,1,15,161.875,53.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6K9-Z-Low Sound Fan,2,94,107.5,16160,14930,9890,11290,2,1,20,161.875,53.125,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7G9-Z-Low Sound Fan,2,94,107.5,17540,16310,10880,12280,2,1,5,167.625,58.875,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7G9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7H9-Z-Low Sound Fan,2,94,107.5,17590,16360,10930,12330,2,1,7.5,167.625,58.875,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7I9-Z-Low Sound Fan,2,94,107.5,17600,16370,10940,12340,2,1,10,167.625,58.875,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7J9-Z-Low Sound Fan,2,94,107.5,17730,16500,11070,12470,2,1,15,167.625,58.875,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7K9-Z-Low Sound Fan,2,94,107.5,17790,16560,11130,12530,2,1,20,167.625,58.875,16.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K9-Z-Low Sound Fan,1,36,910,1700,104,55.625,75,14.25,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3G9-Z-Super Low Sound Fan,2,94,107.5,11940,10710,6830,8230,2,1,5,152.375,30.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3G9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3H9-Z-Super Low Sound Fan,2,94,107.5,11990,10760,6880,8280,2,1,7.5,152.375,30.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3I9-Z-Super Low Sound Fan,2,94,107.5,12000,10770,6890,8290,2,1,10,152.375,30.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3J9-Z-Super Low Sound Fan,2,94,107.5,12130,10900,7020,8420,2,1,15,152.375,30.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4G9-Z-Super Low Sound Fan,2,94,107.5,13420,12190,7920,9320,2,1,5,159.875,38.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4G9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4H9-Z-Super Low Sound Fan,2,94,107.5,13470,12240,7970,9370,2,1,7.5,159.875,38.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4I9-Z-Super Low Sound Fan,2,94,107.5,13480,12250,7980,9380,2,1,10,159.875,38.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4J9-Z-Super Low Sound Fan,2,94,107.5,13610,12380,8110,9510,2,1,15,159.875,38.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-4K9-Z-Super Low Sound Fan,2,94,107.5,13670,12440,8170,9570,2,1,20,159.875,38.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5G9-Z-Super Low Sound Fan,2,94,107.5,14970,13740,9080,10480,2,1,5,167.375,45.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5G9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5H9-Z-Super Low Sound Fan,2,94,107.5,15020,13790,9130,10530,2,1,7.5,167.375,45.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5I9-Z-Super Low Sound Fan,2,94,107.5,15030,13800,9140,10540,2,1,10,167.375,45.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5J9-Z-Super Low Sound Fan,2,94,107.5,15160,13930,9270,10670,2,1,15,167.375,45.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-5K9-Z-Super Low Sound Fan,2,94,107.5,15220,13990,9330,10730,2,1,20,174.875,45.625,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,90.5,39.5,2.625,580,29.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6G9-Z-Super Low Sound Fan,2,94,107.5,16510,15280,10240,11640,2,1,5,174.875,53.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6G9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6H9-Z-Super Low Sound Fan,2,94,107.5,16560,15330,10290,11690,2,1,7.5,174.875,53.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6I9-Z-Super Low Sound Fan,2,94,107.5,16570,15340,10300,11700,2,1,10,174.875,53.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6J9-Z-Super Low Sound Fan,2,94,107.5,16700,15470,10430,11830,2,1,15,174.875,53.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-6K9-Z-Super Low Sound Fan,2,94,107.5,16760,15530,10490,11890,2,1,20,180.625,53.125,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7G9-Z-Super Low Sound Fan,2,94,107.5,18140,16910,11480,12880,2,1,5,180.625,58.875,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7G9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7H9-Z-Super Low Sound Fan,2,94,107.5,18190,16960,11530,12930,2,1,7.5,180.625,58.875,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7I9-Z-Super Low Sound Fan,2,94,107.5,18200,16970,11540,12940,2,1,10,180.625,58.875,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7J9-Z-Super Low Sound Fan,2,94,107.5,18330,17100,11670,13070,2,1,15,180.625,58.875,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-7K9-Z-Super Low Sound Fan,2,94,107.5,18390,17160,11730,13130,2,1,20,180.625,58.875,29.875,88.5,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K9-Z-Super Low Sound Fan,1,36,975,1700,104,55.625,75,14.25,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15.625,0,12,19.82,8.54
ATWB 8-3H11-Z,2,94,125.5,13200,11750,7240,8840,2,1,7.5,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3I11-Z,2,94,125.5,13220,11770,7260,8860,2,1,10,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3J11-Z,2,94,125.5,13340,11890,7380,8980,2,1,15,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3K11-Z,2,94,125.5,13400,11950,7440,9040,2,1,20,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4H11-Z,2,94,125.5,14910,13460,8500,10100,2,1,7.5,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4I11-Z,2,94,125.5,14930,13480,8520,10120,2,1,10,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4J11-Z,2,94,125.5,15050,13600,8640,10240,2,1,15,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4K11-Z,2,94,125.5,15110,13660,8700,10300,2,1,20,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5H11-Z,2,94,125.5,16730,15280,9860,11460,2,1,7.5,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5I11-Z,2,94,125.5,16750,15300,9880,11480,2,1,10,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5J11-Z,2,94,125.5,16870,15420,10000,11600,2,1,15,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5K11-Z,2,94,125.5,16930,15480,10060,11660,2,1,20,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6H11-Z,2,94,125.5,18520,17070,11200,12800,2,1,7.5,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6I11-Z,2,94,125.5,18540,17090,11220,12820,2,1,10,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6J11-Z,2,94,125.5,18660,17210,11340,12940,2,1,15,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6K11-Z,2,94,125.5,18720,17270,11400,13000,2,1,20,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7H11-Z,2,94,125.5,20430,18980,12660,14260,2,1,7.5,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7I11-Z,2,94,125.5,20450,19000,12680,14280,2,1,10,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7J11-Z,2,94,125.5,20570,19120,12800,14400,2,1,15,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7K11-Z,2,94,125.5,20630,19180,12860,14460,2,1,20,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K11-Z,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3H11-Z-Low Sound Fan,2,94,125.5,13200,11750,7240,8840,2,1,7.5,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3I11-Z-Low Sound Fan,2,94,125.5,13220,11770,7260,8860,2,1,10,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3J11-Z-Low Sound Fan,2,94,125.5,13340,11890,7380,8980,2,1,15,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3K11-Z-Low Sound Fan,2,94,125.5,13400,11950,7440,9040,2,1,20,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4H11-Z-Low Sound Fan,2,94,125.5,14910,13460,8500,10100,2,1,7.5,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4I11-Z-Low Sound Fan,2,94,125.5,14930,13480,8520,10120,2,1,10,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4J11-Z-Low Sound Fan,2,94,125.5,15050,13600,8640,10240,2,1,15,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4K11-Z-Low Sound Fan,2,94,125.5,15110,13660,8700,10300,2,1,20,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5H11-Z-Low Sound Fan,2,94,125.5,16730,15280,9860,11460,2,1,7.5,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5I11-Z-Low Sound Fan,2,94,125.5,16750,15300,9880,11480,2,1,10,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5J11-Z-Low Sound Fan,2,94,125.5,16870,15420,10000,11600,2,1,15,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5K11-Z-Low Sound Fan,2,94,125.5,16930,15480,10060,11660,2,1,20,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6H11-Z-Low Sound Fan,2,94,125.5,18520,17070,11200,12800,2,1,7.5,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6I11-Z-Low Sound Fan,2,94,125.5,18540,17090,11220,12820,2,1,10,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6J11-Z-Low Sound Fan,2,94,125.5,18660,17210,11340,12940,2,1,15,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6K11-Z-Low Sound Fan,2,94,125.5,18720,17270,11400,13000,2,1,20,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7H11-Z-Low Sound Fan,2,94,125.5,20430,18980,12660,14260,2,1,7.5,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7I11-Z-Low Sound Fan,2,94,125.5,20450,19000,12680,14280,2,1,10,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7J11-Z-Low Sound Fan,2,94,125.5,20570,19120,12800,14400,2,1,15,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7K11-Z-Low Sound Fan,2,94,125.5,20630,19180,12860,14460,2,1,20,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K11-Z-Low Sound Fan,1,36,1055,1700,104,55.625,83,14.25,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3H11-Z-Super Low Sound Fan,2,94,125.5,13820,12370,7860,9460,2,1,7.5,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3I11-Z-Super Low Sound Fan,2,94,125.5,13840,12390,7880,9480,2,1,10,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3J11-Z-Super Low Sound Fan,2,94,125.5,13960,12510,8000,9600,2,1,15,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3K11-Z-Super Low Sound Fan,2,94,125.5,14020,12570,8060,9660,2,1,20,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,75.5,39.5,9.875,580,34,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4H11-Z-Super Low Sound Fan,2,94,125.5,15530,14080,9120,10720,2,1,7.5,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4I11-Z-Super Low Sound Fan,2,94,125.5,15550,14100,9140,10740,2,1,10,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4J11-Z-Super Low Sound Fan,2,94,125.5,15670,14220,9260,10860,2,1,15,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-4K11-Z-Super Low Sound Fan,2,94,125.5,15730,14280,9320,10920,2,1,20,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,83,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5H11-Z-Super Low Sound Fan,2,94,125.5,17350,15900,10480,12080,2,1,7.5,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5I11-Z-Super Low Sound Fan,2,94,125.5,17370,15920,10500,12100,2,1,10,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5J11-Z-Super Low Sound Fan,2,94,125.5,17490,16040,10620,12220,2,1,15,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-5K11-Z-Super Low Sound Fan,2,94,125.5,17550,16100,10680,12280,2,1,20,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6H11-Z-Super Low Sound Fan,2,94,125.5,19140,17690,11820,13420,2,1,7.5,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6I11-Z-Super Low Sound Fan,2,94,125.5,19160,17710,11840,13440,2,1,10,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6J11-Z-Super Low Sound Fan,2,94,125.5,19280,17830,11960,13560,2,1,15,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-6K11-Z-Super Low Sound Fan,2,94,125.5,19340,17890,12020,13620,2,1,20,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,98,39.5,9.875,580,40.375,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7H11-Z-Super Low Sound Fan,2,94,125.5,21050,19600,13280,14880,2,1,7.5,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7I11-Z-Super Low Sound Fan,2,94,125.5,21070,19620,13300,14900,2,1,10,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7J11-Z-Super Low Sound Fan,2,94,125.5,21190,19740,13420,15020,2,1,15,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-7K11-Z-Super Low Sound Fan,2,94,125.5,21250,19800,13480,15080,2,1,20,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K11-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,14.25,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,20.5,8.54
ATWB 8-3H12-Z,2,94,143.75,14600,12970,7770,9540,2,1,7.5,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3I12-Z,2,94,143.75,14620,12990,7790,9560,2,1,10,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3J12-Z,2,94,143.75,14740,13110,7910,9680,2,1,15,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3K12-Z,2,94,143.75,14800,13170,7970,9740,2,1,20,135.375,30.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4H12-Z,2,94,143.75,16590,14960,9240,11010,2,1,7.5,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4I12-Z,2,94,143.75,16610,14980,9260,11030,2,1,10,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4J12-Z,2,94,143.75,16730,15100,9380,11150,2,1,15,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4K12-Z,2,94,143.75,16790,15160,9440,11210,2,1,20,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4L12-Z,2,94,143.75,16820,15190,9470,11240,2,1,25,142.875,38.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5H12-Z,2,94,143.75,18580,16950,10710,12480,2,1,7.5,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5I12-Z,2,94,143.75,18600,16970,10730,12500,2,1,10,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5J12-Z,2,94,143.75,18720,17090,10850,12620,2,1,15,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5K12-Z,2,94,143.75,18780,17150,10910,12680,2,1,20,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5L12-Z,2,94,143.75,18810,17180,10940,12710,2,1,25,150.375,45.625,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6H12-Z,2,94,143.75,20650,19020,12260,14030,2,1,7.5,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6I12-Z,2,94,143.75,20670,19040,12280,14050,2,1,10,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6J12-Z,2,94,143.75,20790,19160,12400,14170,2,1,15,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6K12-Z,2,94,143.75,20850,19220,12460,14230,2,1,20,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6L12-Z,2,94,143.75,20880,19250,12490,14260,2,1,25,157.875,53.125,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7H12-Z,2,94,143.75,22770,21140,13870,15640,2,1,7.5,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7I12-Z,2,94,143.75,22790,21160,13890,15660,2,1,10,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7J12-Z,2,94,143.75,22910,21280,14010,15780,2,1,15,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7K12-Z,2,94,143.75,22970,21340,14070,15840,2,1,20,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7L12-Z,2,94,143.75,23000,21370,14100,15870,2,1,25,163.625,58.875,12.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L12-Z,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3H12-Z-Low Sound Fan,2,94,143.75,14600,12970,7770,9540,2,1,7.5,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3I12-Z-Low Sound Fan,2,94,143.75,14620,12990,7790,9560,2,1,10,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3J12-Z-Low Sound Fan,2,94,143.75,14740,13110,7910,9680,2,1,15,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3K12-Z-Low Sound Fan,2,94,143.75,14800,13170,7970,9740,2,1,20,139.375,30.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4H12-Z-Low Sound Fan,2,94,143.75,16590,14960,9240,11010,2,1,7.5,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4I12-Z-Low Sound Fan,2,94,143.75,16610,14980,9260,11030,2,1,10,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4J12-Z-Low Sound Fan,2,94,143.75,16730,15100,9380,11150,2,1,15,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4K12-Z-Low Sound Fan,2,94,143.75,16790,15160,9440,11210,2,1,20,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4L12-Z-Low Sound Fan,2,94,143.75,16820,15190,9470,11240,2,1,25,146.875,38.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5H12-Z-Low Sound Fan,2,94,143.75,18580,16950,10710,12480,2,1,7.5,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5I12-Z-Low Sound Fan,2,94,143.75,18600,16970,10730,12500,2,1,10,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5J12-Z-Low Sound Fan,2,94,143.75,18720,17090,10850,12620,2,1,15,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5K12-Z-Low Sound Fan,2,94,143.75,18780,17150,10910,12680,2,1,20,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5L12-Z-Low Sound Fan,2,94,143.75,18810,17180,10940,12710,2,1,25,154.375,45.625,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6H12-Z-Low Sound Fan,2,94,143.75,20650,19020,12260,14030,2,1,7.5,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6I12-Z-Low Sound Fan,2,94,143.75,20670,19040,12280,14050,2,1,10,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6J12-Z-Low Sound Fan,2,94,143.75,20790,19160,12400,14170,2,1,15,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6K12-Z-Low Sound Fan,2,94,143.75,20850,19220,12460,14230,2,1,20,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6L12-Z-Low Sound Fan,2,94,143.75,20880,19250,12490,14260,2,1,25,161.875,53.125,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7H12-Z-Low Sound Fan,2,94,143.75,22770,21140,13870,15640,2,1,7.5,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7I12-Z-Low Sound Fan,2,94,143.75,22790,21160,13890,15660,2,1,10,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7J12-Z-Low Sound Fan,2,94,143.75,22910,21280,14010,15780,2,1,15,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7K12-Z-Low Sound Fan,2,94,143.75,22970,21340,14070,15840,2,1,20,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7L12-Z-Low Sound Fan,2,94,143.75,23000,21370,14100,15870,2,1,25,167.625,58.875,16.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L12-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,41.75,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3H12-Z-Super Low Sound Fan,2,94,143.75,15320,13690,8490,10260,2,1,7.5,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3H12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3I12-Z-Super Low Sound Fan,2,94,143.75,15340,13710,8510,10280,2,1,10,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3J12-Z-Super Low Sound Fan,2,94,143.75,15460,13830,8630,10400,2,1,15,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3K12-Z-Super Low Sound Fan,2,94,143.75,15520,13890,8690,10460,2,1,20,152.375,30.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,75.5,39.5,15.625,580,40.5,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4H12-Z-Super Low Sound Fan,2,94,143.75,17310,15680,9960,11730,2,1,7.5,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4H12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4I12-Z-Super Low Sound Fan,2,94,143.75,17330,15700,9980,11750,2,1,10,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4J12-Z-Super Low Sound Fan,2,94,143.75,17450,15820,10100,11870,2,1,15,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4K12-Z-Super Low Sound Fan,2,94,143.75,17510,15880,10160,11930,2,1,20,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-4L12-Z-Super Low Sound Fan,2,94,143.75,17540,15910,10190,11960,2,1,25,159.875,38.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,83,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5H12-Z-Super Low Sound Fan,2,94,143.75,19300,17670,11430,13200,2,1,7.5,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5H12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5I12-Z-Super Low Sound Fan,2,94,143.75,19320,17690,11450,13220,2,1,10,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5J12-Z-Super Low Sound Fan,2,94,143.75,19440,17810,11570,13340,2,1,15,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5K12-Z-Super Low Sound Fan,2,94,143.75,19500,17870,11630,13400,2,1,20,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-5L12-Z-Super Low Sound Fan,2,94,143.75,19530,17900,11660,13430,2,1,25,167.375,45.625,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,90.5,39.5,15.625,580,43.5,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6H12-Z-Super Low Sound Fan,2,94,143.75,21370,19740,12980,14750,2,1,7.5,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6H12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6I12-Z-Super Low Sound Fan,2,94,143.75,21390,19760,13000,14770,2,1,10,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6J12-Z-Super Low Sound Fan,2,94,143.75,21510,19880,13120,14890,2,1,15,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6K12-Z-Super Low Sound Fan,2,94,143.75,21570,19940,13180,14950,2,1,20,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-6L12-Z-Super Low Sound Fan,2,94,143.75,21600,19970,13210,14980,2,1,25,174.875,53.125,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,98,39.5,15.625,580,46.75,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7H12-Z-Super Low Sound Fan,2,94,143.75,23490,21860,14590,16360,2,1,7.5,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7H12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7I12-Z-Super Low Sound Fan,2,94,143.75,23510,21880,14610,16380,2,1,10,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7J12-Z-Super Low Sound Fan,2,94,143.75,23630,22000,14730,16500,2,1,15,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7K12-Z-Super Low Sound Fan,2,94,143.75,23690,22060,14790,16560,2,1,20,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-7L12-Z-Super Low Sound Fan,2,94,143.75,23720,22090,14820,16590,2,1,25,180.625,58.875,29.875,88.5,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L12-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,23.375,52,88.875,103.75,39.5,15.625,580,49.875,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,15,0,12,22.375,8.54
ATWB 8-3I14-Z,2,94,167.75,16660,14790,8810,10780,2,1,10,139.75,30.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3J14-Z,2,94,167.75,16780,14910,8930,10900,2,1,15,139.75,30.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3K14-Z,2,94,167.75,16840,14970,8990,10960,2,1,20,139.75,30.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3L14-Z,2,94,167.75,16870,15000,9020,10990,2,1,25,139.75,30.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3L14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4I14-Z,2,94,167.75,18970,17100,10510,12480,2,1,10,147.25,38.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4J14-Z,2,94,167.75,19090,17220,10630,12600,2,1,15,147.25,38.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4K14-Z,2,94,167.75,19150,17280,10690,12660,2,1,20,147.25,38.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4L14-Z,2,94,167.75,19180,17310,10720,12690,2,1,25,147.25,38.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4M14-Z,2,94,167.75,19230,17360,10770,12740,2,1,30,147.25,38.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4M14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5I14-Z,2,94,167.75,21280,19410,12210,14180,2,1,10,154.75,45.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5J14-Z,2,94,167.75,21400,19530,12330,14300,2,1,15,154.75,45.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5K14-Z,2,94,167.75,21460,19590,12390,14360,2,1,20,154.75,45.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5L14-Z,2,94,167.75,21490,19620,12420,14390,2,1,25,154.75,45.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5M14-Z,2,94,167.75,21540,19670,12470,14440,2,1,30,154.75,45.625,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5M14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6I14-Z,2,94,167.75,23670,21800,14000,15970,2,1,10,162.25,53.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6J14-Z,2,94,167.75,23790,21920,14120,16090,2,1,15,162.25,53.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6K14-Z,2,94,167.75,23850,21980,14180,16150,2,1,20,162.25,53.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6L14-Z,2,94,167.75,23880,22010,14210,16180,2,1,25,162.25,53.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6M14-Z,2,94,167.75,23930,22060,14260,16230,2,1,30,162.25,53.125,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6M14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7I14-Z,2,94,167.75,26150,24280,15870,17840,2,1,10,168,58.875,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7J14-Z,2,94,167.75,26270,24400,15990,17960,2,1,15,168,58.875,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7K14-Z,2,94,167.75,26330,24460,16050,18020,2,1,20,168,58.875,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7L14-Z,2,94,167.75,26360,24490,16080,18050,2,1,25,168,58.875,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7M14-Z,2,94,167.75,26410,24540,16130,18100,2,1,30,168,58.875,12.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7M14-Z,1,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3I14-Z-Low Sound Fan,2,94,167.75,16660,14790,8810,10780,2,1,10,143.75,30.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3J14-Z-Low Sound Fan,2,94,167.75,16780,14910,8930,10900,2,1,15,143.75,30.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3K14-Z-Low Sound Fan,2,94,167.75,16840,14970,8990,10960,2,1,20,143.75,30.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3L14-Z-Low Sound Fan,2,94,167.75,16870,15000,9020,10990,2,1,25,143.75,30.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3L14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4I14-Z-Low Sound Fan,2,94,167.75,18970,17100,10510,12480,2,1,10,151.25,38.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4J14-Z-Low Sound Fan,2,94,167.75,19090,17220,10630,12600,2,1,15,151.25,38.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4K14-Z-Low Sound Fan,2,94,167.75,19150,17280,10690,12660,2,1,20,151.25,38.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4L14-Z-Low Sound Fan,2,94,167.75,19180,17310,10720,12690,2,1,25,151.25,38.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4M14-Z-Low Sound Fan,2,94,167.75,19230,17360,10770,12740,2,1,30,151.25,38.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4M14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5I14-Z-Low Sound Fan,2,94,167.75,21280,19410,12210,14180,2,1,10,158.75,45.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5J14-Z-Low Sound Fan,2,94,167.75,21400,19530,12330,14300,2,1,15,158.75,45.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5K14-Z-Low Sound Fan,2,94,167.75,21460,19590,12390,14360,2,1,20,158.75,45.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5L14-Z-Low Sound Fan,2,94,167.75,21490,19620,12420,14390,2,1,25,158.75,45.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5M14-Z-Low Sound Fan,2,94,167.75,21540,19670,12470,14440,2,1,30,158.75,45.625,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5M14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6I14-Z-Low Sound Fan,2,94,167.75,23670,21800,14000,15970,2,1,10,166.25,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6J14-Z-Low Sound Fan,2,94,167.75,23790,21920,14120,16090,2,1,15,166.25,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6K14-Z-Low Sound Fan,2,94,167.75,23850,21980,14180,16150,2,1,20,166.25,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6L14-Z-Low Sound Fan,2,94,167.75,23880,22010,14210,16180,2,1,25,166.25,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6M14-Z-Low Sound Fan,2,94,167.75,23930,22060,14260,16230,2,1,30,166.25,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6M14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7I14-Z-Low Sound Fan,2,94,167.75,26150,24280,15870,17840,2,1,10,172,53.125,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7J14-Z-Low Sound Fan,2,94,167.75,26270,24400,15990,17960,2,1,15,172,58.875,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7K14-Z-Low Sound Fan,2,94,167.75,26330,24460,16050,18020,2,1,20,172,58.875,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7L14-Z-Low Sound Fan,2,94,167.75,26360,24490,16080,18050,2,1,25,172,58.875,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7M14-Z-Low Sound Fan,2,94,167.75,26410,24540,16130,18100,2,1,30,172,58.875,16.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7M14-Z-Low Sound Fan,1,36,1150,1700,104,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3I14-Z-Super Low Sound Fan,2,94,167.75,17390,15520,9540,11510,2,1,10,156.75,30.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3I14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3J14-Z-Super Low Sound Fan,2,94,167.75,17510,15640,9660,11630,2,1,15,156.75,30.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3J14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3K14-Z-Super Low Sound Fan,2,94,167.75,17570,15700,9720,11690,2,1,20,156.75,30.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3K14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-3L14-Z-Super Low Sound Fan,2,94,167.75,17600,15730,9750,11720,2,1,25,156.75,30.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-3L14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,24.375,45.25,13.5,22,19.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4I14-Z-Super Low Sound Fan,2,94,167.75,19700,17830,11240,13210,2,1,10,164.25,38.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4I14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4J14-Z-Super Low Sound Fan,2,94,167.75,19820,17950,11360,13330,2,1,15,164.25,38.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4J14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4K14-Z-Super Low Sound Fan,2,94,167.75,19880,18010,11420,13390,2,1,20,164.25,38.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4K14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4L14-Z-Super Low Sound Fan,2,94,167.75,19910,18040,11450,13420,2,1,25,164.25,38.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4L14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-4M14-Z-Super Low Sound Fan,2,94,167.75,19960,18090,11500,13470,2,1,30,164.25,38.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-4M14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,24.375,45.25,13.5,22,27,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5I14-Z-Super Low Sound Fan,2,94,167.75,22010,20140,12940,14910,2,1,10,171.75,45.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5I14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5J14-Z-Super Low Sound Fan,2,94,167.75,22130,20260,13060,15030,2,1,15,171.75,45.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5J14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5K14-Z-Super Low Sound Fan,2,94,167.75,22190,20320,13120,15090,2,1,20,171.75,45.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5K14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5L14-Z-Super Low Sound Fan,2,94,167.75,22220,20350,13150,15120,2,1,25,171.75,45.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5L14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-5M14-Z-Super Low Sound Fan,2,94,167.75,22270,20400,13200,15170,2,1,30,171.75,45.625,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-5M14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,34.5,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6I14-Z-Super Low Sound Fan,2,94,167.75,24400,22530,14730,16700,2,1,10,179.25,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6I14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6J14-Z-Super Low Sound Fan,2,94,167.75,24520,22650,14850,16820,2,1,15,179.25,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6J14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6K14-Z-Super Low Sound Fan,2,94,167.75,24580,22710,14910,16880,2,1,20,179.25,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6K14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6L14-Z-Super Low Sound Fan,2,94,167.75,24610,22740,14940,16910,2,1,25,179.25,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6L14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-6M14-Z-Super Low Sound Fan,2,94,167.75,24660,22790,14990,16960,2,1,30,179.25,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-6M14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,24.375,45.25,13.5,22,42,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7I14-Z-Super Low Sound Fan,2,94,167.75,26880,25010,16600,18570,2,1,10,185,53.125,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7I14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7J14-Z-Super Low Sound Fan,2,94,167.75,27000,25130,16720,18690,2,1,15,185,58.875,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7J14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7K14-Z-Super Low Sound Fan,2,94,167.75,27060,25190,16780,18750,2,1,20,185,58.875,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7K14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7L14-Z-Super Low Sound Fan,2,94,167.75,27090,25220,16810,18780,2,1,25,185,58.875,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7L14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 8-7M14-Z-Super Low Sound Fan,2,94,167.75,27140,25270,16860,18830,2,1,30,185,58.875,29.875,88.5,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",63.5,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"6"" [150] BFW/GVD BOTTOM OUTLET",32.375,13.75,3.75,1,17.125,ATWB 8-7M14-Z-Super Low Sound Fan,1,36,1150,1700,104,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,24.375,45.25,13.5,22,47.75,6,7,4,8.375,8.5,18.25,0,36,22.375,8.54
ATWB 9-3G8-Z,2,89.875,101.5,10150,9050,5490,6790,2,1,5,127.25,30.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3G8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3H8-Z,2,89.875,101.5,10200,9100,5540,6840,2,1,7.5,127.25,30.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3I8-Z,2,89.875,101.5,10210,9110,5550,6850,2,1,10,127.25,30.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3J8-Z,2,89.875,101.5,10340,9240,5680,6980,2,1,15,127.25,30.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4G8-Z,2,89.875,101.5,11450,10350,6450,7750,2,1,5,134.75,38.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4G8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4H8-Z,2,89.875,101.5,11500,10400,6500,7800,2,1,7.5,134.75,38.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4I8-Z,2,89.875,101.5,11510,10410,6510,7810,2,1,10,134.75,38.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4J8-Z,2,89.875,101.5,11640,10540,6640,7940,2,1,15,134.75,38.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5H8-Z,2,89.875,101.5,12890,11790,7550,8850,2,1,7.5,142.25,45.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5I8-Z,2,89.875,101.5,12900,11800,7560,8860,2,1,10,142.25,45.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5J8-Z,2,89.875,101.5,13030,11930,7690,8990,2,1,15,142.25,45.75,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6H8-Z,2,89.875,101.5,14270,13170,8580,9880,2,1,7.5,149.75,53.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6H8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6I8-Z,2,89.875,101.5,14280,13180,8590,9890,2,1,10,149.75,53.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6J8-Z,2,89.875,101.5,14410,13310,8720,10020,2,1,15,149.75,53.25,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7H8-Z,2,89.875,101.5,15740,14640,9710,11010,2,1,7.5,155.5,58.875,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7H8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7I8-Z,2,89.875,101.5,15750,14650,9720,11020,2,1,10,155.5,58.875,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7J8-Z,2,89.875,101.5,15880,14780,9850,11150,2,1,15,155.5,58.875,12.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J8-Z,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3G8-Z-Low Sound Fan,2,89.875,101.5,10150,9050,5490,6790,2,1,5,131.25,30.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3G8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3H8-Z-Low Sound Fan,2,89.875,101.5,10200,9100,5540,6840,2,1,7.5,131.25,30.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3I8-Z-Low Sound Fan,2,89.875,101.5,10210,9110,5550,6850,2,1,10,131.25,30.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3J8-Z-Low Sound Fan,2,89.875,101.5,10340,9240,5680,6980,2,1,15,131.25,30.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4G8-Z-Low Sound Fan,2,89.875,101.5,11450,10350,6450,7750,2,1,5,138.75,38.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4G8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4H8-Z-Low Sound Fan,2,89.875,101.5,11500,10400,6500,7800,2,1,7.5,138.75,38.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4I8-Z-Low Sound Fan,2,89.875,101.5,11510,10410,6510,7810,2,1,10,138.75,38.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4J8-Z-Low Sound Fan,2,89.875,101.5,11640,10540,6640,7940,2,1,15,138.75,38.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5H8-Z-Low Sound Fan,2,89.875,101.5,12890,11790,7550,8850,2,1,7.5,146.25,45.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5I8-Z-Low Sound Fan,2,89.875,101.5,12900,11800,7560,8860,2,1,10,146.25,45.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5J8-Z-Low Sound Fan,2,89.875,101.5,13030,11930,7690,8990,2,1,15,146.25,45.75,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6H8-Z-Low Sound Fan,2,89.875,101.5,14270,13170,8580,9880,2,1,7.5,153.75,53.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6H8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6I8-Z-Low Sound Fan,2,89.875,101.5,14280,13180,8590,9890,2,1,10,153.75,53.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6J8-Z-Low Sound Fan,2,89.875,101.5,14410,13310,8720,10020,2,1,15,153.75,53.25,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7H8-Z-Low Sound Fan,2,89.875,101.5,15740,14640,9710,11010,2,1,7.5,159.5,58.875,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7H8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7I8-Z-Low Sound Fan,2,89.875,101.5,15750,14650,9720,11020,2,1,10,159.5,58.875,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7J8-Z-Low Sound Fan,2,89.875,101.5,15880,14780,9850,11150,2,1,15,159.5,58.875,16.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J8-Z-Low Sound Fan,1,36,850,1500,97.5,55.625,65,15.125,41.5,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3G8-Z-Super Low Sound Fan,2,89.875,101.5,10600,9500,5940,7240,2,1,5,144.25,30.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3G8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3H8-Z-Super Low Sound Fan,2,89.875,101.5,10650,9550,5990,7290,2,1,7.5,144.25,30.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3I8-Z-Super Low Sound Fan,2,89.875,101.5,10660,9560,6000,7300,2,1,10,144.25,30.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3J8-Z-Super Low Sound Fan,2,89.875,101.5,10790,9690,6130,7430,2,1,15,144.25,30.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",37.375,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,70.875,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,19.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4G8-Z-Super Low Sound Fan,2,89.875,101.5,11900,10800,6900,8200,2,1,5,151.75,38.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4G8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4H8-Z-Super Low Sound Fan,2,89.875,101.5,11950,10850,6950,8250,2,1,7.5,151.75,38.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4I8-Z-Super Low Sound Fan,2,89.875,101.5,11960,10860,6960,8260,2,1,10,151.75,38.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-4J8-Z-Super Low Sound Fan,2,89.875,101.5,12090,10990,7090,8390,2,1,15,151.75,38.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",44,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,79.375,41,4.125,580,25.8125,0.5,0,22.5,45.25,11.375,22,27,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5H8-Z-Super Low Sound Fan,2,89.875,101.5,13340,12240,8000,9300,2,1,7.5,159.25,45.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5I8-Z-Super Low Sound Fan,2,89.875,101.5,13350,12250,8010,9310,2,1,10,159.25,45.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-5J8-Z-Super Low Sound Fan,2,89.875,101.5,13480,12380,8140,9440,2,1,15,159.25,45.75,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",51.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,86.875,41,4.125,580,28.75,0.5,0,22.5,45.25,11.375,22,34.5,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6H8-Z-Super Low Sound Fan,2,89.875,101.5,14720,13620,9030,10330,2,1,7.5,166.75,53.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6H8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6I8-Z-Super Low Sound Fan,2,89.875,101.5,14730,13630,9040,10340,2,1,10,166.75,53.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-6J8-Z-Super Low Sound Fan,2,89.875,101.5,14860,13760,9170,10470,2,1,15,166.75,53.25,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",59.875,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,94.375,41,4.125,580,32.1875,0.5,0,22.5,45.25,11.375,22,42,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7H8-Z-Super Low Sound Fan,2,89.875,101.5,16190,15090,10160,11460,2,1,7.5,172.5,58.875,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7H8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7I8-Z-Super Low Sound Fan,2,89.875,101.5,16200,15100,10170,11470,2,1,10,172.5,58.875,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-7J8-Z-Super Low Sound Fan,2,89.875,101.5,16330,15230,10300,11600,2,1,15,172.5,58.875,29.875,82,17,7.125,24.125,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",61.5,1.375,3,15,5.25,0.375,23.125,2,50.75,18.125,6,"6"" [150] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J8-Z-Super Low Sound Fan,1,36,900,1500,97.5,55.625,65,15.125,51.625,88.875,100.125,41,4.125,580,32,0.5,0,22.5,45.25,11.375,22,47.75,5.875,7,4,13.90625,8.5,13.75,0,12,16.63,5.2
ATWB 9-3H9-Z,2,101.5,107.5,12020,10740,6600,8040,2,1,7.5,135.375,30.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,22.5,45.25,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3I9-Z,2,101.5,107.5,12030,10750,6610,8050,2,1,10,135.375,30.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3J9-Z,2,101.5,107.5,12160,10880,6740,8180,2,1,15,135.375,30.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3K9-Z,2,101.5,107.5,12220,10940,6800,8240,2,1,20,135.375,30.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4H9-Z,2,101.5,107.5,13590,12310,7750,9190,2,1,7.5,146.875,38.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4I9-Z,2,101.5,107.5,13600,12320,7760,9200,2,1,10,146.875,38.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4J9-Z,2,101.5,107.5,13730,12450,7890,9330,2,1,15,146.875,38.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4K9-Z,2,101.5,107.5,13790,12510,7950,9390,2,1,20,146.875,38.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5H9-Z,2,101.5,107.5,15270,13990,9010,10450,2,1,7.5,150.375,45.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5I9-Z,2,101.5,107.5,15280,14000,9020,10460,2,1,10,150.375,45.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5J9-Z,2,101.5,107.5,15410,14130,9150,10590,2,1,15,150.375,45.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5K9-Z,2,101.5,107.5,15470,14190,9210,10650,2,1,20,150.375,45.75,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6I9-Z,2,101.5,107.5,16940,15660,10260,11700,2,1,10,157.875,53.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6J9-Z,2,101.5,107.5,17070,15790,10390,11830,2,1,15,157.875,53.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6K9-Z,2,101.5,107.5,17130,15850,10450,11890,2,1,20,157.875,53.25,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7I9-Z,2,101.5,107.5,18850,17570,11760,13200,2,1,10,163.625,58.875,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7J9-Z,2,101.5,107.5,18980,17700,11890,13330,2,1,15,163.625,58.875,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7K9-Z,2,101.5,107.5,19040,17760,11950,13390,2,1,20,163.625,58.875,12.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K9-Z,1,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3H9-Z-Low Sound Fan,2,101.5,107.5,12020,10740,6600,8040,2,1,7.5,139.375,30.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3I9-Z-Low Sound Fan,2,101.5,107.5,12030,10750,6610,8050,2,1,10,139.375,30.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3J9-Z-Low Sound Fan,2,101.5,107.5,12160,10880,6740,8180,2,1,15,139.375,30.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3K9-Z-Low Sound Fan,2,101.5,107.5,12220,10940,6800,8240,2,1,20,139.375,30.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4H9-Z-Low Sound Fan,2,101.5,107.5,13590,12310,7750,9190,2,1,7.5,146.875,38.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4I9-Z-Low Sound Fan,2,101.5,107.5,13600,12320,7760,9200,2,1,10,146.875,38.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4J9-Z-Low Sound Fan,2,101.5,107.5,13730,12450,7890,9330,2,1,15,146.875,38.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4K9-Z-Low Sound Fan,2,101.5,107.5,13790,12510,7950,9390,2,1,20,146.875,38.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5H9-Z-Low Sound Fan,2,101.5,107.5,15270,13990,9010,10450,2,1,7.5,154.375,45.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5I9-Z-Low Sound Fan,2,101.5,107.5,15280,14000,9020,10460,2,1,10,154.375,45.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5J9-Z-Low Sound Fan,2,101.5,107.5,15410,14130,9150,10590,2,1,15,154.375,45.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5K9-Z-Low Sound Fan,2,101.5,107.5,15470,14190,9210,10650,2,1,20,154.375,45.75,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6I9-Z-Low Sound Fan,2,101.5,107.5,16940,15660,10260,11700,2,1,10,161.875,53.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6J9-Z-Low Sound Fan,2,101.5,107.5,17070,15790,10390,11830,2,1,15,161.875,53.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6K9-Z-Low Sound Fan,2,101.5,107.5,17130,15850,10450,11890,2,1,20,161.875,53.25,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7I9-Z-Low Sound Fan,2,101.5,107.5,18850,17570,11760,13200,2,1,10,167.625,58.875,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7J9-Z-Low Sound Fan,2,101.5,107.5,18980,17700,11890,13330,2,1,15,167.625,58.875,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7K9-Z-Low Sound Fan,2,101.5,107.5,19040,17760,11950,13390,2,1,20,167.625,58.875,16.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K9-Z-Low Sound Fan,1,36,980,1800,104,55.625,75,9,41,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3H9-Z-Super Low Sound Fan,2,101.5,107.5,12740,11460,7320,8760,2,1,7.5,156.375,30.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3I9-Z-Super Low Sound Fan,2,101.5,107.5,12750,11470,7330,8770,2,1,10,156.375,30.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3J9-Z-Super Low Sound Fan,2,101.5,107.5,12880,11600,7460,8900,2,1,15,156.375,30.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3K9-Z-Super Low Sound Fan,2,101.5,107.5,12940,11660,7520,8960,2,1,20,156.375,30.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,75.5,39.5,2.625,580,26,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4H9-Z-Super Low Sound Fan,2,101.5,107.5,14310,13030,8470,9910,2,1,7.5,163.875,38.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4I9-Z-Super Low Sound Fan,2,101.5,107.5,14320,13040,8480,9920,2,1,10,163.875,38.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4J9-Z-Super Low Sound Fan,2,101.5,107.5,14450,13170,8610,10050,2,1,15,163.875,38.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-4K9-Z-Super Low Sound Fan,2,101.5,107.5,14510,13230,8670,10110,2,1,20,163.875,38.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,83,39.5,2.625,580,29.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5H9-Z-Super Low Sound Fan,2,101.5,107.5,15990,14710,9730,11170,2,1,7.5,171.375,45.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5H9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5I9-Z-Super Low Sound Fan,2,101.5,107.5,16000,14720,9740,11180,2,1,10,171.375,45.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5J9-Z-Super Low Sound Fan,2,101.5,107.5,16130,14850,9870,11310,2,1,15,171.375,45.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-5K9-Z-Super Low Sound Fan,2,101.5,107.5,16190,14910,9930,11370,2,1,20,171.375,45.75,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,90.5,39.5,2.625,580,29.0625,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6I9-Z-Super Low Sound Fan,2,101.5,107.5,17660,16380,10980,12420,2,1,10,178.875,53.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6I9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6J9-Z-Super Low Sound Fan,2,101.5,107.5,17790,16510,11110,12550,2,1,15,178.875,53.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-6K9-Z-Super Low Sound Fan,2,101.5,107.5,17850,16570,11170,12610,2,1,20,178.875,53.25,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,98,39.5,2.625,580,32.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7I9-Z-Super Low Sound Fan,2,101.5,107.5,19570,18290,12480,13920,2,1,10,184.625,58.875,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7I9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7J9-Z-Super Low Sound Fan,2,101.5,107.5,19700,18420,12610,14050,2,1,15,184.625,58.875,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-7K9-Z-Super Low Sound Fan,2,101.5,107.5,19760,18480,12670,14110,2,1,20,184.625,58.875,33.875,88,17,7.125,27.75,4,"4"" [100] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,53.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K9-Z-Super Low Sound Fan,1,36,1055,1800,104,55.625,75,9,51.25,88.875,103.75,39.5,2.625,580,35.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,19.82,8.54
ATWB 9-3H11-Z,2,101.5,125.5,13920,12410,7600,9240,2,1,7.5,135.375,30.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3I11-Z,2,101.5,125.5,13940,12430,7620,9260,2,1,10,135.375,30.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3J11-Z,2,101.5,125.5,14060,12550,7740,9380,2,1,15,135.375,30.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3K11-Z,2,101.5,125.5,14120,12610,7800,9440,2,1,20,135.375,30.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4H11-Z,2,101.5,125.5,15750,14240,8940,10580,2,1,7.5,142.875,38.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4I11-Z,2,101.5,125.5,15770,14260,8960,10600,2,1,10,142.875,38.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4J11-Z,2,101.5,125.5,15890,14380,9080,10720,2,1,15,142.875,38.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4K11-Z,2,101.5,125.5,15950,14440,9140,10780,2,1,20,142.875,38.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5I11-Z,2,101.5,125.5,17760,16250,10460,12100,2,1,10,150.375,45.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5J11-Z,2,101.5,125.5,17880,16370,10580,12220,2,1,15,150.375,45.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5K11-Z,2,101.5,125.5,17940,16430,10640,12280,2,1,20,150.375,45.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5L11-Z,2,101.5,125.5,17970,16460,10670,12310,2,1,25,150.375,45.75,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6J11-Z,2,101.5,125.5,19790,18280,12000,13640,2,1,15,157.875,53.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6K11-Z,2,101.5,125.5,19850,18340,12060,13700,2,1,20,157.875,53.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6L11-Z,2,101.5,125.5,19880,18370,12090,13730,2,1,25,157.875,53.25,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7J11-Z,2,101.5,125.5,22030,20520,13760,15400,2,1,15,163.625,58.875,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7K11-Z,2,101.5,125.5,22090,20580,13820,15460,2,1,20,163.625,58.875,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7L11-Z,2,101.5,125.5,22120,20610,13850,15490,2,1,25,163.625,58.875,12.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L11-Z,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3H11-Z-Low Sound Fan,2,101.5,125.5,13920,12410,7600,9240,2,1,7.5,139.375,30.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3I11-Z-Low Sound Fan,2,101.5,125.5,13940,12430,7620,9260,2,1,10,139.375,30.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3J11-Z-Low Sound Fan,2,101.5,125.5,14060,12550,7740,9380,2,1,15,139.375,30.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3K11-Z-Low Sound Fan,2,101.5,125.5,14120,12610,7800,9440,2,1,20,139.375,30.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4H11-Z-Low Sound Fan,2,101.5,125.5,15750,14240,8940,10580,2,1,7.5,146.875,38.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4I11-Z-Low Sound Fan,2,101.5,125.5,15770,14260,8960,10600,2,1,10,146.875,38.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4J11-Z-Low Sound Fan,2,101.5,125.5,15890,14380,9080,10720,2,1,15,146.875,38.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4K11-Z-Low Sound Fan,2,101.5,125.5,15950,14440,9140,10780,2,1,20,146.875,38.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5I11-Z-Low Sound Fan,2,101.5,125.5,17760,16250,10460,12100,2,1,10,154.375,45.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5J11-Z-Low Sound Fan,2,101.5,125.5,17880,16370,10580,12220,2,1,15,154.375,45.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5K11-Z-Low Sound Fan,2,101.5,125.5,17940,16430,10640,12280,2,1,20,154.375,45.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5L11-Z-Low Sound Fan,2,101.5,125.5,17970,16460,10670,12310,2,1,25,154.375,45.75,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6J11-Z-Low Sound Fan,2,101.5,125.5,19790,18280,12000,13640,2,1,15,161.875,53.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6K11-Z-Low Sound Fan,2,101.5,125.5,19850,18340,12060,13700,2,1,20,161.875,53.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6L11-Z-Low Sound Fan,2,101.5,125.5,19880,18370,12090,13730,2,1,25,161.875,53.25,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7J11-Z-Low Sound Fan,2,101.5,125.5,22030,20520,13760,15400,2,1,15,167.625,58.875,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7K11-Z-Low Sound Fan,2,101.5,125.5,22090,20580,13820,15460,2,1,20,167.625,58.875,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7L11-Z-Low Sound Fan,2,101.5,125.5,22120,20610,13850,15490,2,1,25,167.625,58.875,16.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L11-Z-Low Sound Fan,1,36,1140,1800,104,55.625,83,14.625,41.75,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3H11-Z-Super Low Sound Fan,2,101.5,125.5,14650,13140,8330,9970,2,1,7.5,156.375,30.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3H11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3I11-Z-Super Low Sound Fan,2,101.5,125.5,14670,13160,8350,9990,2,1,10,156.375,30.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3J11-Z-Super Low Sound Fan,2,101.5,125.5,14790,13280,8470,10110,2,1,15,156.375,30.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3K11-Z-Super Low Sound Fan,2,101.5,125.5,14850,13340,8530,10170,2,1,20,156.375,30.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,75.5,39.5,9.875,580,34,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4H11-Z-Super Low Sound Fan,2,101.5,125.5,16480,14970,9670,11310,2,1,7.5,163.875,38.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4H11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4I11-Z-Super Low Sound Fan,2,101.5,125.5,16500,14990,9690,11330,2,1,10,163.875,38.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4J11-Z-Super Low Sound Fan,2,101.5,125.5,16620,15110,9810,11450,2,1,15,163.875,38.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-4K11-Z-Super Low Sound Fan,2,101.5,125.5,16680,15170,9870,11510,2,1,20,163.875,38.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,83,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5I11-Z-Super Low Sound Fan,2,101.5,125.5,18490,16980,11190,12830,2,1,10,171.375,45.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5I11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5J11-Z-Super Low Sound Fan,2,101.5,125.5,18610,17100,11310,12950,2,1,15,171.375,45.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5K11-Z-Super Low Sound Fan,2,101.5,125.5,18670,17160,11370,13010,2,1,20,171.375,45.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-5L11-Z-Super Low Sound Fan,2,101.5,125.5,18700,17190,11400,13040,2,1,25,171.375,45.75,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,90.5,39.5,9.875,580,37.125,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6J11-Z-Super Low Sound Fan,2,101.5,125.5,20520,19010,12730,14370,2,1,15,178.875,53.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6K11-Z-Super Low Sound Fan,2,101.5,125.5,20580,19070,12790,14430,2,1,20,178.875,53.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-6L11-Z-Super Low Sound Fan,2,101.5,125.5,20610,19100,12820,14460,2,1,25,178.875,53.25,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,98,39.5,9.875,580,40.375,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7J11-Z-Super Low Sound Fan,2,101.5,125.5,22760,21250,14490,16130,2,1,15,184.625,58.875,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7K11-Z-Super Low Sound Fan,2,101.5,125.5,22820,21310,14550,16190,2,1,20,184.625,58.875,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-7L11-Z-Super Low Sound Fan,2,101.5,125.5,22850,21340,14580,16220,2,1,25,184.625,58.875,33.875,92,17,7.125,27.75,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,62.75,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L11-Z-Super Low Sound Fan,1,36,1240,1800,104,55.625,83,14.625,52,88.875,103.75,39.5,9.875,580,43.5,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,20.5,8.54
ATWB 9-3I12-Z,2,101.5,143.75,15380,13670,8150,9950,2,1,10,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3J12-Z,2,101.5,143.75,15510,13800,8280,10080,2,1,15,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3K12-Z,2,101.5,143.75,15570,13860,8340,10140,2,1,20,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3L12-Z,2,101.5,143.75,15600,13890,8370,10170,2,1,25,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4I12-Z,2,101.5,143.75,17510,15800,9720,11520,2,1,10,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4J12-Z,2,101.5,143.75,17640,15930,9850,11650,2,1,15,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4K12-Z,2,101.5,143.75,17700,15990,9910,11710,2,1,20,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4L12-Z,2,101.5,143.75,17730,16020,9940,11740,2,1,25,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5J12-Z,2,101.5,143.75,19790,18080,11440,13240,2,1,15,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5K12-Z,2,101.5,143.75,19850,18140,11500,13300,2,1,20,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5L12-Z,2,101.5,143.75,19880,18170,11530,13330,2,1,25,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5M12-Z,2,101.5,143.75,19930,18220,11580,13380,2,1,30,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6J12-Z,2,101.5,143.75,21980,20270,13070,14870,2,1,15,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6K12-Z,2,101.5,143.75,22040,20330,13130,14930,2,1,20,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6L12-Z,2,101.5,143.75,22070,20360,13160,14960,2,1,25,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6M12-Z,2,101.5,143.75,22120,20410,13210,15010,2,1,30,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7J12-Z,2,101.5,143.75,24480,22770,15000,16800,2,1,15,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7K12-Z,2,101.5,143.75,24540,22830,15060,16860,2,1,20,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7L12-Z,2,101.5,143.75,24570,22860,15090,16890,2,1,25,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7M12-Z,2,101.5,143.75,24620,22910,15140,16940,2,1,30,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M12-Z,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3I12-Z-Low Sound Fan,2,101.5,143.75,15380,13670,8150,9950,2,1,10,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3J12-Z-Low Sound Fan,2,101.5,143.75,15510,13800,8280,10080,2,1,15,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3K12-Z-Low Sound Fan,2,101.5,143.75,15570,13860,8340,10140,2,1,20,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3L12-Z-Low Sound Fan,2,101.5,143.75,15600,13890,8370,10170,2,1,25,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4I12-Z-Low Sound Fan,2,101.5,143.75,17510,15800,9720,11520,2,1,10,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4J12-Z-Low Sound Fan,2,101.5,143.75,17640,15930,9850,11650,2,1,15,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4K12-Z-Low Sound Fan,2,101.5,143.75,17700,15990,9910,11710,2,1,20,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4L12-Z-Low Sound Fan,2,101.5,143.75,17730,16020,9940,11740,2,1,25,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5J12-Z-Low Sound Fan,2,101.5,143.75,19790,18080,11440,13240,2,1,15,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5K12-Z-Low Sound Fan,2,101.5,143.75,19850,18140,11500,13300,2,1,20,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5L12-Z-Low Sound Fan,2,101.5,143.75,19880,18170,11530,13330,2,1,25,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5M12-Z-Low Sound Fan,2,101.5,143.75,19930,18220,11580,13380,2,1,30,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6J12-Z-Low Sound Fan,2,101.5,143.75,21980,20270,13070,14870,2,1,15,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6K12-Z-Low Sound Fan,2,101.5,143.75,22040,20330,13130,14930,2,1,20,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6L12-Z-Low Sound Fan,2,101.5,143.75,22070,20360,13160,14960,2,1,25,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6M12-Z-Low Sound Fan,2,101.5,143.75,22120,20410,13210,15010,2,1,30,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7J12-Z-Low Sound Fan,2,101.5,143.75,24480,22770,15000,16800,2,1,15,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7K12-Z-Low Sound Fan,2,101.5,143.75,24540,22830,15060,16860,2,1,20,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7L12-Z-Low Sound Fan,2,101.5,143.75,24570,22860,15090,16890,2,1,25,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7M12-Z-Low Sound Fan,2,101.5,143.75,24620,22910,15140,16940,2,1,30,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M12-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,21.625,41.75,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3I12-Z-Super Low Sound Fan,2,101.5,143.75,16200,14490,8970,10770,2,1,10,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3J12-Z-Super Low Sound Fan,2,101.5,143.75,16330,14620,9100,10900,2,1,15,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3K12-Z-Super Low Sound Fan,2,101.5,143.75,16390,14680,9160,10960,2,1,20,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3L12-Z-Super Low Sound Fan,2,101.5,143.75,16420,14710,9190,10990,2,1,25,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,79.875,39.5,15.625,590,40.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4I12-Z-Super Low Sound Fan,2,101.5,143.75,18330,16620,10540,12340,2,1,10,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4I12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4J12-Z-Super Low Sound Fan,2,101.5,143.75,18460,16750,10670,12470,2,1,15,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4K12-Z-Super Low Sound Fan,2,101.5,143.75,18520,16810,10730,12530,2,1,20,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-4L12-Z-Super Low Sound Fan,2,101.5,143.75,18550,16840,10760,12560,2,1,25,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,87.375,39.5,15.625,590,43.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5J12-Z-Super Low Sound Fan,2,101.5,143.75,20610,18900,12260,14060,2,1,15,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5K12-Z-Super Low Sound Fan,2,101.5,143.75,20670,18960,12320,14120,2,1,20,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5L12-Z-Super Low Sound Fan,2,101.5,143.75,20700,18990,12350,14150,2,1,25,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-5M12-Z-Super Low Sound Fan,2,101.5,143.75,20750,19040,12400,14200,2,1,30,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,94.875,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6J12-Z-Super Low Sound Fan,2,101.5,143.75,22800,21090,13890,15690,2,1,15,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6J12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6K12-Z-Super Low Sound Fan,2,101.5,143.75,22860,21150,13950,15750,2,1,20,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6L12-Z-Super Low Sound Fan,2,101.5,143.75,22890,21180,13980,15780,2,1,25,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-6M12-Z-Super Low Sound Fan,2,101.5,143.75,22940,21230,14030,15830,2,1,30,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,102.375,39.5,15.625,590,46.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7J12-Z-Super Low Sound Fan,2,101.5,143.75,25300,23590,15820,17620,2,1,15,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7J12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7K12-Z-Super Low Sound Fan,2,101.5,143.75,25360,23650,15880,17680,2,1,20,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7L12-Z-Super Low Sound Fan,2,101.5,143.75,25390,23680,15910,17710,2,1,25,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-7M12-Z-Super Low Sound Fan,2,101.5,143.75,25440,23730,15960,17760,2,1,30,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,71.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M12-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,21.625,52,88.875,108.125,39.5,15.625,590,50,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,15.625,0,12,22.375,8.54
ATWB 9-3I14-Z,2,101.5,167.75,17550,15590,9230,11240,2,1,10,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3J14-Z,2,101.5,167.75,17680,15720,9360,11370,2,1,15,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3K14-Z,2,101.5,167.75,17740,15780,9420,11430,2,1,20,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3L14-Z,2,101.5,167.75,17770,15810,9450,11460,2,1,25,139.75,30.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4J14-Z,2,101.5,167.75,20160,18200,11180,13190,2,1,15,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4K14-Z,2,101.5,167.75,20220,18260,11240,13250,2,1,20,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4L14-Z,2,101.5,167.75,20250,18290,11270,13280,2,1,25,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4M14-Z,2,101.5,167.75,20300,18340,11320,13330,2,1,30,147.25,38.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4M14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5J14-Z,2,101.5,167.75,22650,20690,13020,15030,2,1,15,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5K14-Z,2,101.5,167.75,22710,20750,13080,15090,2,1,20,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5L14-Z,2,101.5,167.75,22740,20780,13110,15120,2,1,25,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5M14-Z,2,101.5,167.75,22790,20830,13160,15170,2,1,30,154.75,45.75,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6K14-Z,2,101.5,167.75,25280,23320,14990,17000,2,1,20,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6L14-Z,2,101.5,167.75,25310,23350,15020,17030,2,1,25,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6M14-Z,2,101.5,167.75,25360,23400,15070,17080,2,1,30,162.25,53.25,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7K14-Z,2,101.5,167.75,28180,26220,17240,19250,2,1,20,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7L14-Z,2,101.5,167.75,28210,26250,17270,19280,2,1,25,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7M14-Z,2,101.5,167.75,28260,26300,17320,19330,2,1,30,168,58.875,12.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M14-Z,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3I14-Z-Low Sound Fan,2,101.5,167.75,17550,15590,9230,11240,2,1,10,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3I14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3J14-Z-Low Sound Fan,2,101.5,167.75,17680,15720,9360,11370,2,1,15,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3J14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3K14-Z-Low Sound Fan,2,101.5,167.75,17740,15780,9420,11430,2,1,20,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3L14-Z-Low Sound Fan,2,101.5,167.75,17770,15810,9450,11460,2,1,25,143.75,30.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4J14-Z-Low Sound Fan,2,101.5,167.75,20160,18200,11180,13190,2,1,15,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4K14-Z-Low Sound Fan,2,101.5,167.75,20220,18260,11240,13250,2,1,20,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4L14-Z-Low Sound Fan,2,101.5,167.75,20250,18290,11270,13280,2,1,25,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4M14-Z-Low Sound Fan,2,101.5,167.75,20300,18340,11320,13330,2,1,30,151.25,38.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4M14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5J14-Z-Low Sound Fan,2,101.5,167.75,22650,20690,13020,15030,2,1,15,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5K14-Z-Low Sound Fan,2,101.5,167.75,22710,20750,13080,15090,2,1,20,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5L14-Z-Low Sound Fan,2,101.5,167.75,22740,20780,13110,15120,2,1,25,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5M14-Z-Low Sound Fan,2,101.5,167.75,22790,20830,13160,15170,2,1,30,158.75,45.75,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6K14-Z-Low Sound Fan,2,101.5,167.75,25280,23320,14990,17000,2,1,20,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6L14--Z-Low Sound Fan,2,101.5,167.75,25310,23350,15020,17030,2,1,25,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L14--Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6M14-Z-Low Sound Fan,2,101.5,167.75,25360,23400,15070,17080,2,1,30,166.25,53.25,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7K14-Z-Low Sound Fan,2,101.5,167.75,28180,26220,17240,19250,2,1,20,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7L14-Z-Low Sound Fan,2,101.5,167.75,28210,26250,17270,19280,2,1,25,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7M14-Z-Low Sound Fan,2,101.5,167.75,28260,26300,17320,19330,2,1,30,172,58.875,16.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M14-Z-Low Sound Fan,1,36,1140,2020,124.75,55.625,83,33,41.75,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3K14-Z-Super Low Sound Fan,2,101.5,167.75,18420,16460,10100,12110,2,1,10,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3K14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-3L14-Z-Super Low Sound Fan,2,101.5,167.75,18550,16590,10230,12240,2,1,15,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-3L14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4J14-Z-Super Low Sound Fan,2,101.5,167.75,18610,16650,10290,12300,2,1,20,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4J14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4K14-Z-Super Low Sound Fan,2,101.5,167.75,18640,16680,10320,12330,2,1,25,160.75,30.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",37.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4K14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,79.875,39.5,27.625,620,53.5625,0.5,0,26.375,48.75,14.125,23.75,19.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4L14-Z-Super Low Sound Fan,2,101.5,167.75,21030,19070,12050,14060,2,1,15,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4L14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-4M14-Z-Super Low Sound Fan,2,101.5,167.75,21090,19130,12110,14120,2,1,20,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-4M14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5J14-Z-Super Low Sound Fan,2,101.5,167.75,21120,19160,12140,14150,2,1,25,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5J14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5K14-Z-Super Low Sound Fan,2,101.5,167.75,21170,19210,12190,14200,2,1,30,168.25,38.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",44.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5K14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,87.375,39.5,27.625,620,56.625,0.5,0,26.375,48.75,14.125,23.75,27,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5L14-Z-Super Low Sound Fan,2,101.5,167.75,23520,21560,13890,15900,2,1,15,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5L14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-5M14-Z-Super Low Sound Fan,2,101.5,167.75,23580,21620,13950,15960,2,1,20,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-5M14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6K14-Z-Super Low Sound Fan,2,101.5,167.75,23610,21650,13980,15990,2,1,25,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6K14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6L14-Z-Super Low Sound Fan,2,101.5,167.75,23660,21700,14030,16040,2,1,30,175.75,45.75,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",52.25,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6L14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,94.875,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,34.5,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-6M14-Z-Super Low Sound Fan,2,101.5,167.75,26150,24190,15860,17870,2,1,20,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-6M14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7K14-Z-Super Low Sound Fan,2,101.5,167.75,26180,24220,15890,17900,2,1,25,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7K14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7L14-Z-Super Low Sound Fan,2,101.5,167.75,26230,24270,15940,17950,2,1,30,183.25,53.25,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",59.75,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7L14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,102.375,39.5,27.625,620,59.875,0.5,0,26.375,48.75,14.125,23.75,42,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 9-7M14-Z-Super Low Sound Fan,2,101.5,167.75,29050,27090,18110,20120,2,1,20,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 9-7M14-Z-Super Low Sound Fan,1,36,1240,2020,124.75,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 10-3I12-Z,2,101.5,167.75,29080,27120,18140,20150,2,1,25,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,2,4.25,"2"" [50] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 10-3I12-Z,1,36,1240,2020,124.75,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 10-3J12-Z,2,101.5,167.75,29130,27170,18190,20200,2,1,30,189,58.875,33.875,100,17,7.125,32.125,6,"6"" [150] FPT INLET",65.5,3,1.625,3,4.25,"3"" [80] MPT DRAIN",67.25,1.375,3,15,5.25,0.375,23.125,2,65.875,18.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",29,13.75,3.875,1,17.125,ATWB 10-3J12-Z,1,36,1240,2020,124.75,55.625,83,33,52,88.875,108.125,39.5,27.625,620,63,0.5,0,26.375,48.75,14.125,23.75,47.75,6,7,4,13.90625,8.5,16.125,0,36,22.375,8.54
ATWB 10-3K12-Z,2,117.75,143.75,19890,16320,9840,12390,2,1,10,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3L12-Z,2,117.75,143.75,20020,16450,9970,12520,2,1,15,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3M12-Z,2,117.75,143.75,20080,16510,10030,12580,2,1,20,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4I12-Z,2,117.75,143.75,20110,16540,10060,12610,2,1,25,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4J12-Z,2,117.75,143.75,20160,16590,10110,12660,2,1,30,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4K12-Z,2,117.75,143.75,22430,18860,11720,14270,2,1,10,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4L12-Z,2,117.75,143.75,22560,18990,11850,14400,2,1,15,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4M12-Z,2,117.75,143.75,22620,19050,11910,14460,2,1,20,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5I12-Z,2,117.75,143.75,22650,19080,11940,14490,2,1,25,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5J12-Z,2,117.75,143.75,22700,19130,11990,14540,2,1,30,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5K12-Z,2,117.75,143.75,24870,21300,13500,16050,2,1,10,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5L12-Z,2,117.75,143.75,25000,21430,13630,16180,2,1,15,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5M12-Z,2,117.75,143.75,25060,21490,13690,16240,2,1,20,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6I12-Z,2,117.75,143.75,25090,21520,13720,16270,2,1,25,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6J12-Z,2,117.75,143.75,25140,21570,13770,16320,2,1,30,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6K12-Z,2,117.75,143.75,27450,23880,15420,17970,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6L12-Z,2,117.75,143.75,27580,24010,15550,18100,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6M12-Z,2,117.75,143.75,27640,24070,15610,18160,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7I12-Z,2,117.75,143.75,27670,24100,15640,18190,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7J12-Z,2,117.75,143.75,27720,24150,15690,18240,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7K12-Z,2,117.75,143.75,30350,26780,17660,20210,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7L12-Z,2,117.75,143.75,30480,26910,17790,20340,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7M12-Z,2,117.75,143.75,30540,26970,17850,20400,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M12-Z,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3I12-Z-Low Sound Fan,2,117.75,143.75,30570,27000,17880,20430,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3I12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3J12-Z-Low Sound Fan,2,117.75,143.75,30620,27050,17930,20480,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3J12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3K12-Z-Low Sound Fan,2,117.75,143.75,19890,16320,9840,12390,2,1,10,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3L12-Z-Low Sound Fan,2,117.75,143.75,20020,16450,9970,12520,2,1,15,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3M12-Z-Low Sound Fan,2,117.75,143.75,20080,16510,10030,12580,2,1,20,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4I12-Z-Low Sound Fan,2,117.75,143.75,20110,16540,10060,12610,2,1,25,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4J12-Z-Low Sound Fan,2,117.75,143.75,20160,16590,10110,12660,2,1,30,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4K12-Z-Low Sound Fan,2,117.75,143.75,22430,18860,11720,14270,2,1,10,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4L12-Z-Low Sound Fan,2,117.75,143.75,22560,18990,11850,14400,2,1,15,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4M12-Z-Low Sound Fan,2,117.75,143.75,22620,19050,11910,14460,2,1,20,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5I12-Z-Low Sound Fan,2,117.75,143.75,22650,19080,11940,14490,2,1,25,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5J12-Z-Low Sound Fan,2,117.75,143.75,22700,19130,11990,14540,2,1,30,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5K12-Z-Low Sound Fan,2,117.75,143.75,24870,21300,13500,16050,2,1,10,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5L12-Z-Low Sound Fan,2,117.75,143.75,25000,21430,13630,16180,2,1,15,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5M12-Z-Low Sound Fan,2,117.75,143.75,25060,21490,13690,16240,2,1,20,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6I12-Z-Low Sound Fan,2,117.75,143.75,25090,21520,13720,16270,2,1,25,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6J12-Z-Low Sound Fan,2,117.75,143.75,25140,21570,13770,16320,2,1,30,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6K12-Z-Low Sound Fan,2,117.75,143.75,27450,23880,15420,17970,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6L12-Z-Low Sound Fan,2,117.75,143.75,27580,24010,15550,18100,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6M12-Z-Low Sound Fan,2,117.75,143.75,27640,24070,15610,18160,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7I12-Z-Low Sound Fan,2,117.75,143.75,27670,24100,15640,18190,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7J12-Z-Low Sound Fan,2,117.75,143.75,27720,24150,15690,18240,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7K12-Z-Low Sound Fan,2,117.75,143.75,30350,26780,17660,20210,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7L12-Z-Low Sound Fan,2,117.75,143.75,30480,26910,17790,20340,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7M12-Z-Low Sound Fan,2,117.75,143.75,30540,26970,17850,20400,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M12-Z-Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3I12-Z-Super Low Sound Fan,2,117.75,143.75,30570,27000,17880,20430,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3I12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3J12-Z-Super Low Sound Fan,2,117.75,143.75,30620,27050,17930,20480,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3J12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,43.75,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3K12-Z-Super Low Sound Fan,2,117.75,143.75,20920,17350,10870,13420,2,1,10,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3L12-Z-Super Low Sound Fan,2,117.75,143.75,21050,17480,11000,13550,2,1,15,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3M12-Z-Super Low Sound Fan,2,117.75,143.75,21110,17540,11060,13610,2,1,20,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4I12-Z-Super Low Sound Fan,2,117.75,143.75,21140,17570,11090,13640,2,1,25,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4J12-Z-Super Low Sound Fan,2,117.75,143.75,21190,17620,11140,13690,2,1,30,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,106,39.5,2.25,540,48.6875,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4K12-Z-Super Low Sound Fan,2,117.75,143.75,23460,19890,12750,15300,2,1,10,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4L12-Z-Super Low Sound Fan,2,117.75,143.75,23590,20020,12880,15430,2,1,15,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-4M12-Z-Super Low Sound Fan,2,117.75,143.75,23650,20080,12940,15490,2,1,20,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5I12-Z-Super Low Sound Fan,2,117.75,143.75,23680,20110,12970,15520,2,1,25,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5J12-Z-Super Low Sound Fan,2,117.75,143.75,23730,20160,13020,15570,2,1,30,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,114.5,39.5,2.25,540,46.875,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5K12-Z-Super Low Sound Fan,2,117.75,143.75,25900,22330,14530,17080,2,1,10,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5L12-Z-Super Low Sound Fan,2,117.75,143.75,26030,22460,14660,17210,2,1,15,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-5M12-Z-Super Low Sound Fan,2,117.75,143.75,26090,22520,14720,17270,2,1,20,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6I12-Z-Super Low Sound Fan,2,117.75,143.75,26120,22550,14750,17300,2,1,25,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6J12-Z-Super Low Sound Fan,2,117.75,143.75,26170,22600,14800,17350,2,1,30,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,123,39.5,2.25,540,49.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6K12-Z-Super Low Sound Fan,2,117.75,143.75,28480,24910,16450,19000,2,1,10,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6L12-Z-Super Low Sound Fan,2,117.75,143.75,28610,25040,16580,19130,2,1,15,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-6M12-Z-Super Low Sound Fan,2,117.75,143.75,28670,25100,16640,19190,2,1,20,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7I12-Z-Super Low Sound Fan,2,117.75,143.75,28700,25130,16670,19220,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7J12-Z-Super Low Sound Fan,2,117.75,143.75,28750,25180,16720,19270,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7K12-Z-Super Low Sound Fan,2,117.75,143.75,31380,27810,18690,21240,2,1,10,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7L12-Z-Super Low Sound Fan,2,117.75,143.75,31510,27940,18820,21370,2,1,15,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-7M12-Z-Super Low Sound Fan,2,117.75,143.75,31570,28000,18880,21430,2,1,20,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M12-Z-Super Low Sound Fan,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3I18-Z,2,117.75,143.75,31600,28030,18910,21460,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3I18-Z,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3J18-Z,2,117.75,143.75,31650,28080,18960,21510,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3J18-Z,1,36,1730,1730,143.625,55.625,78,50.75,54.5,64.875,131.5,39.5,2.25,540,53.03125,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17,1,36.125,22.375,8.54
ATWB 10-3K18-Z,2,117.75,216,28910,23660,13990,17640,2,1,10,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3L18-Z,2,117.75,216,29040,23790,14120,17770,2,1,15,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3M18-Z,2,117.75,216,29100,23850,14180,17830,2,1,20,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3N18-Z,2,117.75,216,29130,23880,14210,17860,2,1,25,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3N18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4I18-Z,2,117.75,216,29180,23930,14260,17910,2,1,30,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4J18-Z,2,117.75,216,29340,24090,14420,18070,2,1,40,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4K18-Z,2,117.75,216,32700,27450,16780,20430,2,1,10,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4L18-Z,2,117.75,216,32830,27580,16910,20560,2,1,15,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4M18-Z,2,117.75,216,32890,27640,16970,20620,2,1,20,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4N18-Z,2,117.75,216,32920,27670,17000,20650,2,1,25,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4N18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5I18-Z,2,117.75,216,32970,27720,17050,20700,2,1,30,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5J18-Z,2,117.75,216,33130,27880,17210,20860,2,1,40,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5K18-Z,2,117.75,216,36390,31140,19480,23130,2,1,10,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5L18-Z,2,117.75,216,36520,31270,19610,23260,2,1,15,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5M18-Z,2,117.75,216,36580,31330,19670,23320,2,1,20,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5N18-Z,2,117.75,216,36610,31360,19700,23350,2,1,25,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5N18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6I18-Z,2,117.75,216,36660,31410,19750,23400,2,1,30,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6J18-Z,2,117.75,216,36820,31570,19910,23560,2,1,40,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6K18-Z,2,117.75,216,40260,35010,22350,26000,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6L18-Z,2,117.75,216,40390,35140,22480,26130,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6M18-Z,2,117.75,216,40450,35200,22540,26190,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6N18-Z,2,117.75,216,40480,35230,22570,26220,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6N18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7I18-Z,2,117.75,216,40530,35280,22620,26270,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7J18-Z,2,117.75,216,40690,35440,22780,26430,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7K18-Z,2,117.75,216,44610,39360,25710,29360,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7L18-Z,2,117.75,216,44740,39490,25840,29490,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7M18-Z,2,117.75,216,44800,39550,25900,29550,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7N18-Z,2,117.75,216,44830,39580,25930,29580,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7N18-Z,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3I18-Z-Low Sound Fan,2,117.75,216,44880,39630,25980,29630,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3I18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3J18-Z-Low Sound Fan,2,117.75,216,45040,39790,26140,29790,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3J18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3K18-Z-Low Sound Fan,2,117.75,216,28910,23660,13990,17640,2,1,10,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3L18-Z-Low Sound Fan,2,117.75,216,29040,23790,14120,17770,2,1,15,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3M18-Z-Low Sound Fan,2,117.75,216,29100,23850,14180,17830,2,1,20,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3N18-Z-Low Sound Fan,2,117.75,216,29130,23880,14210,17860,2,1,25,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3N18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4I18-Z-Low Sound Fan,2,117.75,216,29180,23930,14260,17910,2,1,30,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4J18-Z-Low Sound Fan,2,117.75,216,29340,24090,14420,18070,2,1,40,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4K18-Z-Low Sound Fan,2,117.75,216,32700,27450,16780,20430,2,1,10,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4L18-Z-Low Sound Fan,2,117.75,216,32830,27580,16910,20560,2,1,15,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4M18-Z-Low Sound Fan,2,117.75,216,32890,27640,16970,20620,2,1,20,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4N18-Z-Low Sound Fan,2,117.75,216,32920,27670,17000,20650,2,1,25,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4N18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5I18-Z-Low Sound Fan,2,117.75,216,32970,27720,17050,20700,2,1,30,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5J18-Z-Low Sound Fan,2,117.75,216,33130,27880,17210,20860,2,1,40,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5K18-Z-Low Sound Fan,2,117.75,216,36390,31140,19480,23130,2,1,10,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5L18-Z-Low Sound Fan,2,117.75,216,36520,31270,19610,23260,2,1,15,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5M18-Z-Low Sound Fan,2,117.75,216,36580,31330,19670,23320,2,1,20,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5N18-Z-Low Sound Fan,2,117.75,216,36610,31360,19700,23350,2,1,25,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5N18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6I18-Z-Low Sound Fan,2,117.75,216,36660,31410,19750,23400,2,1,30,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6J18-Z-Low Sound Fan,2,117.75,216,36820,31570,19910,23560,2,1,40,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6K18-Z-Low Sound Fan,2,117.75,216,40260,35010,22350,26000,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6L18-Z-Low Sound Fan,2,117.75,216,40390,35140,22480,26130,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6M18-Z-Low Sound Fan,2,117.75,216,40450,35200,22540,26190,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6N18-Z-Low Sound Fan,2,117.75,216,40480,35230,22570,26220,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6N18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7I18-Z-Low Sound Fan,2,117.75,216,40530,35280,22620,26270,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7J18-Z-Low Sound Fan,2,117.75,216,40690,35440,22780,26430,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7K18-Z-Low Sound Fan,2,117.75,216,44610,39360,25710,29360,2,1,10,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7L18-Z-Low Sound Fan,2,117.75,216,44740,39490,25840,29490,2,1,15,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7M18-Z-Low Sound Fan,2,117.75,216,44800,39550,25900,29550,2,1,20,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7N18-Z-Low Sound Fan,2,117.75,216,44830,39580,25930,29580,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7N18-Z-Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3I18-Z-Super Low Sound Fan,2,117.75,216,44880,39630,25980,29630,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3I18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3J18-Z-Super Low Sound Fan,2,117.75,216,45040,39790,26140,29790,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3J18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,43.75,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3K18-Z-Super Low Sound Fan,2,117.75,216,30070,24820,15150,18800,2,1,10,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3K18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3L18-Z-Super Low Sound Fan,2,117.75,216,30200,24950,15280,18930,2,1,15,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3L18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3M18-Z-Super Low Sound Fan,2,117.75,216,30260,25010,15340,18990,2,1,20,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3M18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-3N18-Z-Super Low Sound Fan,2,117.75,216,30290,25040,15370,19020,2,1,25,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-3N18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4I18-Z-Super Low Sound Fan,2,117.75,216,30340,25090,15420,19070,2,1,30,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4I18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4J18-Z-Super Low Sound Fan,2,117.75,216,30500,25250,15580,19230,2,1,40,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4J18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,106,39.5,37.875,620,81.625,7,0.5,30.375,57,16.375,28,22.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4K18-Z-Super Low Sound Fan,2,117.75,216,33860,28610,17940,21590,2,1,10,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4K18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4L18-Z-Super Low Sound Fan,2,117.75,216,33990,28740,18070,21720,2,1,15,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4L18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4M18-Z-Super Low Sound Fan,2,117.75,216,34050,28800,18130,21780,2,1,20,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4M18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-4N18-Z-Super Low Sound Fan,2,117.75,216,34080,28830,18160,21810,2,1,25,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-4N18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5I18-Z-Super Low Sound Fan,2,117.75,216,34130,28880,18210,21860,2,1,30,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5I18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5J18-Z-Super Low Sound Fan,2,117.75,216,34290,29040,18370,22020,2,1,40,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5J18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,114.5,39.5,37.875,620,85.75,7,0.5,30.375,57,16.375,28,30.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5K18-Z-Super Low Sound Fan,2,117.75,216,37550,32300,20640,24290,2,1,10,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5K18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5L18-Z-Super Low Sound Fan,2,117.75,216,37680,32430,20770,24420,2,1,15,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5L18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5M18-Z-Super Low Sound Fan,2,117.75,216,37740,32490,20830,24480,2,1,20,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5M18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-5N18-Z-Super Low Sound Fan,2,117.75,216,37770,32520,20860,24510,2,1,25,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-5N18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6I18-Z-Super Low Sound Fan,2,117.75,216,37820,32570,20910,24560,2,1,30,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6I18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6J18-Z-Super Low Sound Fan,2,117.75,216,37980,32730,21070,24720,2,1,40,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6J18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,123,39.5,37.875,620,87.875,7,0.5,30.375,57,16.375,28,39.25,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6K18-Z-Super Low Sound Fan,2,117.75,216,41420,36170,23510,27160,2,1,10,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6K18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6L18-Z-Super Low Sound Fan,2,117.75,216,41550,36300,23640,27290,2,1,15,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6L18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6M18-Z-Super Low Sound Fan,2,117.75,216,41610,36360,23700,27350,2,1,20,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6M18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-6N18-Z-Super Low Sound Fan,2,117.75,216,41640,36390,23730,27380,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-6N18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7I18-Z-Super Low Sound Fan,2,117.75,216,41690,36440,23780,27430,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7I18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7J18-Z-Super Low Sound Fan,2,117.75,216,41850,36600,23940,27590,2,1,40,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7J18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7K18-Z-Super Low Sound Fan,2,117.75,216,45770,40520,26870,30520,2,1,10,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7K18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7L18-Z-Super Low Sound Fan,2,117.75,216,45900,40650,27000,30650,2,1,15,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7L18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7M18-Z-Super Low Sound Fan,2,117.75,216,45960,40710,27060,30710,2,1,20,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7M18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 10-7N18-Z-Super Low Sound Fan,2,117.75,216,45990,40740,27090,30740,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 10-7N18-Z-Super Low Sound Fan,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 12-3J12-Z,2,117.75,216,46040,40790,27140,30790,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3J12-Z,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 12-3K12-Z,2,117.75,216,46200,40950,27300,30950,2,1,40,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",71.75,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K12-Z,1,36,1730,1730,157.5,55.625,78,50.75,54.5,64.875,131.5,39.5,37.875,620,90.4375,7,0.5,30.375,57,16.375,28,47.75,6,7,4,8.375,8.5,17.25,1,36.125,22.375,8.54
ATWB 12-3L12-Z,2,142,143.75,22870,18920,11540,14250,2,1,15,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3M12-Z,2,142,143.75,22930,18980,11600,14310,2,1,20,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4J12-Z,2,142,143.75,22960,19010,11630,14340,2,1,25,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4J12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4K12-Z,2,142,143.75,23010,19060,11680,14390,2,1,30,161.875,43.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4L12-Z,2,142,143.75,26000,22050,13850,16560,2,1,15,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4M12-Z,2,142,143.75,26060,22110,13910,16620,2,1,20,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4N12-Z,2,142,143.75,26090,22140,13940,16650,2,1,25,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5K12-Z,2,142,143.75,26140,22190,13990,16700,2,1,30,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5K12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5L12-Z,2,142,143.75,26300,22350,14150,16860,2,1,40,170.375,51.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5M12-Z,2,142,143.75,29050,25100,16090,18800,2,1,20,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5N12-Z,2,142,143.75,29080,25130,16120,18830,2,1,25,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6L12-Z,2,142,143.75,29130,25180,16170,18880,2,1,30,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6M12-Z,2,142,143.75,29290,25340,16330,19040,2,1,40,178.875,60.3125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6N12-Z,2,142,143.75,32250,28300,18480,21190,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7L12-Z,2,142,143.75,32300,28350,18530,21240,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7M12-Z,2,142,143.75,32460,28510,18690,21400,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7N12-Z,2,142,143.75,35680,31730,21100,23810,2,1,25,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N12-Z,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3J12-Z-Low Sound Fan,2,142,143.75,35730,31780,21150,23860,2,1,30,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3J12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3K12-Z-Low Sound Fan,2,142,143.75,35890,31940,21310,24020,2,1,40,187.375,68.8125,15.25,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,43.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3L12-Z-Low Sound Fan,2,142,143.75,22870,18920,11540,14250,2,1,15,161.90625,43.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3M12-Z-Low Sound Fan,2,142,143.75,22930,18980,11600,14310,2,1,20,161.90625,43.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4J12-Z-Low Sound Fan,2,142,143.75,22960,19010,11630,14340,2,1,25,161.90625,43.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4J12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4K12-Z-Low Sound Fan,2,142,143.75,23010,19060,11680,14390,2,1,30,161.90625,43.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4L12-Z-Low Sound Fan,2,142,143.75,26000,22050,13850,16560,2,1,15,170.65625,51.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4M12-Z-Low Sound Fan,2,142,143.75,26060,22110,13910,16620,2,1,20,170.65625,51.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4N12-Z-Low Sound Fan,2,142,143.75,26090,22140,13940,16650,2,1,25,170.65625,51.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5K12-Z-Low Sound Fan,2,142,143.75,26140,22190,13990,16700,2,1,30,170.65625,51.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5K12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5L12-Z-Low Sound Fan,2,142,143.75,26300,22350,14150,16860,2,1,40,170.65625,51.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5M12-Z-Low Sound Fan,2,142,143.75,29050,25100,16090,18800,2,1,20,178.90625,60.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5N12-Z-Low Sound Fan,2,142,143.75,29080,25130,16120,18830,2,1,25,178.90625,60.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6L12-Z-Low Sound Fan,2,142,143.75,29130,25180,16170,18880,2,1,30,178.90625,60.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6M12-Z-Low Sound Fan,2,142,143.75,29290,25340,16330,19040,2,1,40,178.90625,60.3125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6N12-Z-Low Sound Fan,2,142,143.75,32250,28300,18480,21190,2,1,25,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7L12-Z-Low Sound Fan,2,142,143.75,32300,28350,18530,21240,2,1,30,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7M12-Z-Low Sound Fan,2,142,143.75,32460,28510,18690,21400,2,1,40,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7N12-Z-Low Sound Fan,2,142,143.75,35680,31730,21100,23810,2,1,25,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N12-Z-Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3J12-Z-Super Low Sound Fan,2,142,143.75,35730,31780,21150,23860,2,1,30,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3J12-Z-Super Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3K12-Z-Super Low Sound Fan,2,142,143.75,35890,31940,21310,24020,2,1,40,187.40625,68.8125,15.28125,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K12-Z-Super Low Sound Fan,1,36,1800,2940,143.625,55.625,88,49.375,75.75,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3L12-Z-Super Low Sound Fan,2,142,143.75,23660,19710,12330,15040,2,1,15,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3M12-Z-Super Low Sound Fan,2,142,143.75,23720,19770,12390,15100,2,1,20,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4J12-Z-Super Low Sound Fan,2,142,143.75,23750,19800,12420,15130,2,1,25,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4J12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4K12-Z-Super Low Sound Fan,2,142,143.75,23800,19850,12470,15180,2,1,30,183.375,43.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,106,39.5,2.25,540,48.6875,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4L12-Z-Super Low Sound Fan,2,142,143.75,26790,22840,14640,17350,2,1,15,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4M12-Z-Super Low Sound Fan,2,142,143.75,26850,22900,14700,17410,2,1,20,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-4N12-Z-Super Low Sound Fan,2,142,143.75,26880,22930,14730,17440,2,1,25,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5K12-Z-Super Low Sound Fan,2,142,143.75,26930,22980,14780,17490,2,1,30,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5K12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5L12-Z-Super Low Sound Fan,2,142,143.75,27090,23140,14940,17650,2,1,40,191.875,51.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,114.5,39.5,2.25,540,46.875,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5M12-Z-Super Low Sound Fan,2,142,143.75,29840,25890,16880,19590,2,1,20,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-5N12-Z-Super Low Sound Fan,2,142,143.75,29870,25920,16910,19620,2,1,25,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6L12-Z-Super Low Sound Fan,2,142,143.75,29920,25970,16960,19670,2,1,30,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6M12-Z-Super Low Sound Fan,2,142,143.75,30080,26130,17120,19830,2,1,40,200.375,60.3125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,123,39.5,2.25,540,49.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-6N12-Z-Super Low Sound Fan,2,142,143.75,33040,29090,19270,21980,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7L12-Z-Super Low Sound Fan,2,142,143.75,33090,29140,19320,22030,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7M12-Z-Super Low Sound Fan,2,142,143.75,33250,29300,19480,22190,2,1,40,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-7N12-Z-Super Low Sound Fan,2,142,143.75,36470,32520,21890,24600,2,1,25,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N12-Z-Super Low Sound Fan,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3K14-Z,2,142,143.75,36520,32570,21940,24650,2,1,30,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K14-Z,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3L14-Z,2,142,143.75,36680,32730,22100,24810,2,1,40,208.875,68.8125,36.75,112,19,7.125,36.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,71.875,24.125,8,"8"" [200] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L14-Z,1,36,2150,2940,143.625,55.625,88,49.375,54.25,64.875,131.5,39.5,2.25,540,53,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,36.125,22.375,8.54
ATWB 12-3M14-Z,2,142,167.75,26340,21770,13160,16220,2,1,20,167.875,43.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3N14-Z,2,142,167.75,26370,21800,13190,16250,2,1,25,167.875,43.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4K14-Z,2,142,167.75,26420,21850,13240,16300,2,1,30,167.875,43.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4L14-Z,2,142,167.75,26580,22010,13400,16460,2,1,40,167.875,43.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4M14-Z,2,142,167.75,29970,25400,15840,18900,2,1,20,176.375,51.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4N14-Z,2,142,167.75,30000,25430,15870,18930,2,1,25,176.375,51.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5L14-Z,2,142,167.75,30050,25480,15920,18980,2,1,30,176.375,51.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5M14-Z,2,142,167.75,30210,25640,16080,19140,2,1,40,176.375,51.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5N14-Z,2,142,167.75,33460,28890,18380,21440,2,1,25,184.875,60.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6L14-Z,2,142,167.75,33510,28940,18430,21490,2,1,30,184.875,60.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6M14-Z,2,142,167.75,33670,29100,18590,21650,2,1,40,184.875,60.3125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6N14-Z,2,142,167.75,37400,32830,21370,24430,2,1,25,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7L14-Z,2,142,167.75,37450,32880,21420,24480,2,1,30,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7M14-Z,2,142,167.75,37610,33040,21580,24640,2,1,40,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7N14-Z,2,142,167.75,41450,36880,24470,27530,2,1,25,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N14-Z,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3K14-Z-Low Sound Fan,2,142,167.75,41500,36930,24520,27580,2,1,30,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3L14-Z-Low Sound Fan,2,142,167.75,41660,37090,24680,27740,2,1,40,193.375,68.8125,15.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,43.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3M14-Z-Low Sound Fan,2,142,167.75,26565,21995,13385,16445,2,1,20,174.875,43.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3N14-Z-Low Sound Fan,2,142,167.75,26595,22025,13415,16475,2,1,25,174.875,43.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4K14-Z-Low Sound Fan,2,142,167.75,26645,22075,13465,16525,2,1,30,174.875,43.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4L14-Z-Low Sound Fan,2,142,167.75,26805,22235,13625,16685,2,1,40,174.875,43.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4M14-Z-Low Sound Fan,2,142,167.75,30195,25625,16065,19125,2,1,20,183.375,51.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4N14-Z-Low Sound Fan,2,142,167.75,30225,25655,16095,19155,2,1,25,183.375,51.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5L14-Z-Low Sound Fan,2,142,167.75,30275,25705,16145,19205,2,1,30,183.375,51.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5M14-Z-Low Sound Fan,2,142,167.75,30435,25865,16305,19365,2,1,40,183.375,51.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5N14-Z-Low Sound Fan,2,142,167.75,33685,29115,18605,21665,2,1,25,191.875,60.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6L14-Z-Low Sound Fan,2,142,167.75,33735,29165,18655,21715,2,1,30,191.875,60.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6M14-Z-Low Sound Fan,2,142,167.75,33895,29325,18815,21875,2,1,40,191.875,60.3125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6N14-Z-Low Sound Fan,2,142,167.75,37625,33055,21595,24655,2,1,25,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7L14-Z-Low Sound Fan,2,142,167.75,37675,33105,21645,24705,2,1,30,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7M14-Z-Low Sound Fan,2,142,167.75,37835,33265,21805,24865,2,1,40,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7N14-Z-Low Sound Fan,2,142,167.75,41675,37105,24695,27755,2,1,25,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N14-Z-Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3K14-Z-Super Low Sound Fan,2,142,167.75,41725,37155,24745,27805,2,1,30,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K14-Z-Super Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3L14-Z-Super Low Sound Fan,2,142,167.75,41885,37315,24905,27965,2,1,40,200.375,68.8125,22.25,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L14-Z-Super Low Sound Fan,1,36,1835,2940,143.625,55.625,88,49.375,75.75,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3M14-Z-Super Low Sound Fan,2,142,167.75,27480,22910,14300,17360,2,1,20,189.375,43.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3N14-Z-Super Low Sound Fan,2,142,167.75,27510,22940,14330,17390,2,1,25,189.375,43.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4K14-Z-Super Low Sound Fan,2,142,167.75,27560,22990,14380,17440,2,1,30,189.375,43.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4L14-Z-Super Low Sound Fan,2,142,167.75,27720,23150,14540,17600,2,1,40,189.375,43.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,112,39.5,14.25,560,57.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4M14-Z-Super Low Sound Fan,2,142,167.75,31110,26540,16980,20040,2,1,20,197.875,51.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-4N14-Z-Super Low Sound Fan,2,142,167.75,31140,26570,17010,20070,2,1,25,197.875,51.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5L14-Z-Super Low Sound Fan,2,142,167.75,31190,26620,17060,20120,2,1,30,197.875,51.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5M14-Z-Super Low Sound Fan,2,142,167.75,31350,26780,17220,20280,2,1,40,197.875,51.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,120.5,39.5,14.25,560,59.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-5N14-Z-Super Low Sound Fan,2,142,167.75,34600,30030,19520,22580,2,1,25,206.375,60.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6L14-Z-Super Low Sound Fan,2,142,167.75,34650,30080,19570,22630,2,1,30,206.375,60.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6L14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6M14-Z-Super Low Sound Fan,2,142,167.75,34810,30240,19730,22790,2,1,40,206.375,60.3125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,129,39.5,14.25,560,64.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-6N14-Z-Super Low Sound Fan,2,142,167.75,38540,33970,22510,25570,2,1,25,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7L14-Z-Super Low Sound Fan,2,142,167.75,38590,34020,22560,25620,2,1,30,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7L14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7M14-Z-Super Low Sound Fan,2,142,167.75,38750,34180,22720,25780,2,1,40,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-7N14-Z-Super Low Sound Fan,2,142,167.75,42590,38020,25610,28670,2,1,25,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N14-Z-Super Low Sound Fan,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3K18-Z,2,142,167.75,42640,38070,25660,28720,2,1,30,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K18-Z,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3L18-Z,2,142,167.75,42800,38230,25820,28880,2,1,40,214.875,68.8125,30.75,132,19,7.125,42.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,65.875,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L18-Z,1,36,2100,2940,143.625,55.625,88,49.375,54.25,64.875,137.5,39.5,14.25,560,65.125,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,16.75,1,42.125,22.375,8.54
ATWB 12-3M18-Z,2,142,216,33210,27340,16350,20270,2,1,20,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3N18-Z,2,142,216,33240,27370,16380,20300,2,1,25,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4K18-Z,2,142,216,33290,27420,16430,20350,2,1,30,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4L18-Z,2,142,216,33450,27580,16590,20510,2,1,40,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4M18-Z,2,142,216,37870,32000,19780,23700,2,1,20,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4N18-Z,2,142,216,37900,32030,19810,23730,2,1,25,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4O18-Z,2,142,216,37950,32080,19860,23780,2,1,30,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5L18-Z,2,142,216,38110,32240,20020,23940,2,1,40,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5M18-Z,2,142,216,38120,32250,20030,23950,2,1,50,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5N18-Z,2,142,216,42410,36540,23100,27020,2,1,25,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5O18-Z,2,142,216,42460,36590,23150,27070,2,1,30,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6M18-Z,2,142,216,42620,36750,23310,27230,2,1,40,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6N18-Z,2,142,216,42630,36760,23320,27240,2,1,50,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6O18-Z,2,142,216,47090,41220,26550,30470,2,1,30,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6P18-Z,2,142,216,47250,41380,26710,30630,2,1,40,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7M18-Z,2,142,216,47260,41390,26720,30640,2,1,50,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7N18-Z,2,142,216,47460,41590,26920,30840,2,1,60,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7O18-Z,2,142,216,52240,46370,30470,34390,2,1,30,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7P18-Z,2,142,216,52400,46530,30630,34550,2,1,40,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P18-Z,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3K18-Z-Low Sound Fan,2,142,216,52410,46540,30640,34560,2,1,50,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3L18-Z-Low Sound Fan,2,142,216,52610,46740,30840,34760,2,1,60,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,43.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3M18-Z-Low Sound Fan,2,142,216,33435,27565,16575,20495,2,1,20,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3N18-Z-Low Sound Fan,2,142,216,33465,27595,16605,20525,2,1,25,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4K18-Z-Low Sound Fan,2,142,216,33515,27645,16655,20575,2,1,30,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4L18-Z-Low Sound Fan,2,142,216,33675,27805,16815,20735,2,1,40,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4M18-Z-Low Sound Fan,2,142,216,38095,32225,20005,23925,2,1,20,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4N18-Z-Low Sound Fan,2,142,216,38125,32255,20035,23955,2,1,25,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4O18-Z-Low Sound Fan,2,142,216,38175,32305,20085,24005,2,1,30,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5L18-Z-Low Sound Fan,2,142,216,38335,32465,20245,24165,2,1,40,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5M18-Z-Low Sound Fan,2,142,216,38345,32475,20255,24175,2,1,50,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5N18-Z-Low Sound Fan,2,142,216,42635,36765,23325,27245,2,1,25,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5O18-Z-Low Sound Fan,2,142,216,42685,36815,23375,27295,2,1,30,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6M18-Z-Low Sound Fan,2,142,216,42845,36975,23535,27455,2,1,40,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6N18-Z-Low Sound Fan,2,142,216,42855,36985,23545,27465,2,1,50,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6O18-Z-Low Sound Fan,2,142,216,47315,41445,26775,30695,2,1,30,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6P18-Z-Low Sound Fan,2,142,216,47475,41605,26935,30855,2,1,40,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7M18-Z-Low Sound Fan,2,142,216,47485,41615,26945,30865,2,1,50,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7N18-Z-Low Sound Fan,2,142,216,47685,41815,27145,31065,2,1,60,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7O18-Z-Low Sound Fan,2,142,216,52465,46595,30695,34615,2,1,30,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7P18-Z-Low Sound Fan,2,142,216,52625,46755,30855,34775,2,1,40,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P18-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3K18-Z-Super Low Sound Fan,2,142,216,52635,46765,30865,34785,2,1,50,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3K18-Z-Super Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3L18-Z-Super Low Sound Fan,2,142,216,52835,46965,31065,34985,2,1,60,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L18-Z-Super Low Sound Fan,1,36,1835,3350,157.5,55.625,88,85.5,68.75,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3M18-Z-Super Low Sound Fan,2,142,216,34450,28580,17590,21510,2,1,20,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3N18-Z-Super Low Sound Fan,2,142,216,34480,28610,17620,21540,2,1,25,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4K18-Z-Super Low Sound Fan,2,142,216,34530,28660,17670,21590,2,1,30,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4K18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4L18-Z-Super Low Sound Fan,2,142,216,34690,28820,17830,21750,2,1,40,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,118,39.5,37.875,620,82.25,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4M18-Z-Super Low Sound Fan,2,142,216,39110,33240,21020,24940,2,1,20,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4N18-Z-Super Low Sound Fan,2,142,216,39140,33270,21050,24970,2,1,25,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-4O18-Z-Super Low Sound Fan,2,142,216,39190,33320,21100,25020,2,1,30,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5L18-Z-Super Low Sound Fan,2,142,216,39350,33480,21260,25180,2,1,40,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5L18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5M18-Z-Super Low Sound Fan,2,142,216,39360,33490,21270,25190,2,1,50,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,126.5,39.5,37.875,620,85.75,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5N18-Z-Super Low Sound Fan,2,142,216,43650,37780,24340,28260,2,1,25,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-5O18-Z-Super Low Sound Fan,2,142,216,43700,37830,24390,28310,2,1,30,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6M18-Z-Super Low Sound Fan,2,142,216,43860,37990,24550,28470,2,1,40,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6M18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6N1-Z-Super Low Sound Fan,2,142,216,43870,38000,24560,28480,2,1,50,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N1-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,135,39.5,37.875,620,87.875,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6O18-Z-Super Low Sound Fan,2,142,216,48330,42460,27790,31710,2,1,30,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-6P18-Z-Super Low Sound Fan,2,142,216,48490,42620,27950,31870,2,1,40,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7M18-Z-Super Low Sound Fan,2,142,216,48500,42630,27960,31880,2,1,50,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7M18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7N18-Z-Super Low Sound Fan,2,142,216,48700,42830,28160,32080,2,1,60,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7O18-Z-Super Low Sound Fan,2,142,216,53480,47610,31710,35630,2,1,30,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-7P18-Z-Super Low Sound Fan,2,142,216,53640,47770,31870,35790,2,1,40,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P18-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3L20-Z,2,142,216,53650,47780,31880,35800,2,1,50,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L20-Z,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3M20-Z,2,142,216,53850,47980,32080,36000,2,1,60,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,90,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M20-Z,1,36,2100,3350,157.5,55.625,88,85.5,60.375,64.875,143.5,39.5,37.875,620,90.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,23.125,1,48.125,22.375,8.54
ATWB 12-3N20-Z,2,142,240,36840,30140,17860,22370,2,1,25,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3O20-Z,2,142,240,36890,30190,17910,22420,2,1,30,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3O20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4L20-Z,2,142,240,37050,30350,18070,22580,2,1,40,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4M20-Z,2,142,240,37060,30360,18080,22590,2,1,50,173.875,43.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4N20-Z,2,142,240,41990,35290,21640,26150,2,1,25,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4O20-Z,2,142,240,42040,35340,21690,26200,2,1,30,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5M20-Z,2,142,240,42200,35500,21850,26360,2,1,40,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5N20-Z,2,142,240,42210,35510,21860,26370,2,1,50,182.375,51.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5O20-Z,2,142,240,47090,40390,25370,29880,2,1,30,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5P20-Z,2,142,240,47250,40550,25530,30040,2,1,40,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5P20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6N20-Z,2,142,240,47260,40560,25540,30050,2,1,50,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6O20-Z,2,142,240,47460,40760,25740,30250,2,1,60,190.875,60.3125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6P20-Z,2,142,240,52750,46050,29670,34180,2,1,40,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7N20-Z,2,142,240,52760,46060,29680,34190,2,1,50,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7O20-Z,2,142,240,52960,46260,29880,34390,2,1,60,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7P20-Z,2,142,240,58560,51860,34110,38620,2,1,40,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P20-Z,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3L20-Z-Low Sound Fan,2,142,240,58570,51870,34120,38630,2,1,50,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3M20-Z-Low Sound Fan,2,142,240,58770,52070,34320,38830,2,1,60,199.375,68.8125,15.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,43.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3N20-Z-Low Sound Fan,2,142,240,37065,30365,18085,22595,2,1,25,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3O20-Z-Low Sound Fan,2,142,240,37115,30415,18135,22645,2,1,30,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3O20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4L20-Z-Low Sound Fan,2,142,240,37275,30575,18295,22805,2,1,40,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4M20-Z-Low Sound Fan,2,142,240,37285,30585,18305,22815,2,1,50,180.875,43.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4N20-Z-Low Sound Fan,2,142,240,42215,35515,21865,26375,2,1,25,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4O20-Z-Low Sound Fan,2,142,240,42265,35565,21915,26425,2,1,30,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5M20-Z-Low Sound Fan,2,142,240,42425,35725,22075,26585,2,1,40,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5N20-Z-Low Sound Fan,2,142,240,42435,35735,22085,26595,2,1,50,189.375,51.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5O20-Z-Low Sound Fan,2,142,240,47315,40615,25595,30105,2,1,30,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5P20-Z-Low Sound Fan,2,142,240,47475,40775,25755,30265,2,1,40,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5P20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6N20-Z-Low Sound Fan,2,142,240,47485,40785,25765,30275,2,1,50,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6O20-Z-Low Sound Fan,2,142,240,47685,40985,25965,30475,2,1,60,197.875,60.3125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6P20-Z-Low Sound Fan,2,142,240,52975,46275,29895,34405,2,1,40,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7N20-Z-Low Sound Fan,2,142,240,52985,46285,29905,34415,2,1,50,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7O20-Z-Low Sound Fan,2,142,240,53185,46485,30105,34615,2,1,60,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7P20-Z-Low Sound Fan,2,142,240,58785,52085,34335,38845,2,1,40,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P20-Z-Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3L20-Z-Super Low Sound Fan,2,142,240,58795,52095,34345,38855,2,1,50,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3L20-Z-Super Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3M20-Z-Super Low Sound Fan,2,142,240,58995,52295,34545,39055,2,1,60,206.375,68.8125,22.25,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3M20-Z-Super Low Sound Fan,1,36,1835,3350,157.5,55.625,88,97.5,68.75,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3N20-Z-Super Low Sound Fan,2,142,240,38080,31380,19100,23610,2,1,25,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3N20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-3O20-Z-Super Low Sound Fan,2,142,240,38130,31430,19150,23660,2,1,30,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-3O20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4L20-Z-Super Low Sound Fan,2,142,240,38290,31590,19310,23820,2,1,40,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4L20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4M20-Z-Super Low Sound Fan,2,142,240,38300,31600,19320,23830,2,1,50,189.375,43.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",38.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4M20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,118,39.5,49.375,640,92.5,7,0.5,36.375,69.25,19.75,34.25,22.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4N20-Z-Super Low Sound Fan,2,142,240,43230,36530,22880,27390,2,1,25,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4N20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-4O20-Z-Super Low Sound Fan,2,142,240,43280,36580,22930,27440,2,1,30,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-4O20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5M20-Z-Super Low Sound Fan,2,142,240,43440,36740,23090,27600,2,1,40,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5M20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5N20-Z-Super Low Sound Fan,2,142,240,43450,36750,23100,27610,2,1,50,197.875,51.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",47.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5N20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,126.5,39.5,49.375,640,98.0625,7,0.5,36.375,69.25,19.75,34.25,30.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5O20-Z-Super Low Sound Fan,2,142,240,48330,41630,26610,31120,2,1,30,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5O20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-5P20-Z-Super Low Sound Fan,2,142,240,48490,41790,26770,31280,2,1,40,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-5P20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6N20-Z-Super Low Sound Fan,2,142,240,48500,41800,26780,31290,2,1,50,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6N20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6O20-Z-Super Low Sound Fan,2,142,240,48700,42000,26980,31490,2,1,60,206.375,60.3125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",55.75,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6O20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,135,39.5,49.375,640,99.625,7,0.5,36.375,69.25,19.75,34.25,39.25,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-6P20-Z-Super Low Sound Fan,2,142,240,53990,47290,30910,35420,2,1,40,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-6P20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7N20-Z-Super Low Sound Fan,2,142,240,54000,47300,30920,35430,2,1,50,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7N20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7O20-Z-Super Low Sound Fan,2,142,240,54200,47500,31120,35630,2,1,60,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7P20-Z-Super Low Sound Fan,2,142,240,59800,53100,35350,39860,2,1,40,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7O20-Z-Super Low Sound Fan,2,142,240,59810,53110,35360,39870,2,1,50,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7O20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54
ATWB 12-7P20-Z-Super Low Sound Fan,2,142,240,60010,53310,35560,40070,2,1,60,214.875,68.8125,30.75,132,19,7.125,48.125,6,"6"" [150] FPT INLET",64.25,3.625,1.625,3,4.25,"3"" [80] MPT DRAIN",86,1.375,3,17,5.25,0.375,25.25,2,102.25,24.125,10,"10"" [250] BFW/GVD BOTTOM OUTLET",57.25,33.625,3.75,1.75,10.125,ATWB 12-7P20-Z-Super Low Sound Fan,1,36,2100,3350,157.5,55.625,88,97.5,60.375,64.875,143.5,39.5,49.375,640,102.4375,7,0.5,36.375,69.25,19.75,34.25,47.75,6,7,4,8.375,8.5,24.5,1,48.125,22.375,8.54